background image

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

Date: 

07/15/16

 

 

BF1 Series

Bottle Filler, Pushbutton Operated

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 

 

 

 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

LIMITED WARRANTY - UNITED STATES & CANADA

Murdock warrants that its products are free from defects in material or workmanship under normal use and 
service for a period of one year from date of original shipment or for 18 months after the date of shipment from the 
factory, whichever comes first. Murdock’s liability under this warranty shall be discharged solely by replacement 
or repair of defective material, provided Murdock is notified in writing within one year from date of shipment, 
F.O.B. Industry, California. 

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

LIMITED EXPORT WARRANTY - 

One year on parts only. 

COMPLIES 

WITH

Member of

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

7109-708-001

www.murdockmfg.com

 WATER COOLERS

 

Summary of Contents for BF1 Series

Page 1: ...damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replaceme...

Page 2: ...ces to absorb the hammer caused by high pressure resulting from the quick closing of the valve These pressure absorbing devices shall be approved mechanical devices Water pressure absorbing devices will be installed as close as possible to the quick closing valve Water supply inlet is 1 4 OD polyethylene tube Completely flush supply of all foreign debris before connecting to fixture Bottle filler ...

Page 3: ... as shown and attach to wall with mounting fasteners by others 9 In drinking cooler access compartment attach the Y strainer provided to existing 3 8 OD copper inlet tube and connect outlet of Y strainer to existing 1 4 OD evaporator inlet tube see page 4 10 In drinking cooler access compartment remove the 1 4 push in fitting from evaporator outlet and replace it with 1 4 push in tee fitting Recon...

Page 4: ...STRUCTIONS CONTINUED WATER TUBING CONNECTIONS To cartridge 30 PE Tube to valve inlet From cold water tube from evaporator Cut tube and Install tee Special Instructions Bi Level Drinking Fountains ONLY INSERT DETAIL When mounting bottle filler on unit with no compressor only NOTE Insulation on all water tubes not shown all PE water tubes are insulated Fill Tube Pushbutton Assembly Valve Outlet Elbl...

Page 5: ...65 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Please visit www murdockmfg com for most current specifications MCBF1 Install Maintenance Instructions RETRO FIT INSTALL FOR EXISTING WATER COOLER FIXTURE PRESSURIZED SINGLE UNIT PIPE INSTALLATION WITH GF BF OPTIONS ITEM PART NUMBER DESCRIPTION QTY 1 7012 055 000 FOAM INSULATION PIPE 3 8 ID x 1 4 THICK 5 5 2 2169 000 000 TUBING LLDPE...

Page 6: ... To re pipe a single non pressurized unit to pressurized you will have to move the water supply tubing around with NO additional tubing needed Before performing this task you MUST SHUT OFF THE WATER SUPPLY and disconnect all supply connections STEP 3 From the outlet of the cartridge assembly connect to the bubbler STEP 1 Starting with the supply line coming from the wall connect to the inlet of th...

Page 7: ...on the fitted tubing to ensure it is secure Tube should not come free from the fitting Water test the connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to re...

Page 8: ...ller system or the structure supply pipping will cause an irregular spout outlet stream until purged out by incoming water Hold cup or similar object directly below filler spout is recommended when first activating bottle filler to prevent excessive splashing Press and hold pushbutton until steady water stream is achieved 2 Using the same method hold cup or similar object directly over bubbler s a...

Page 9: ...bow clogged remove clean f The water cooler may also develop a freezing condition in which the water will become frozen inside the evaporator coil This indicates a refrigeration problem or thermostat failure in which case the water cooler needs to be checked by a qualified technician CLEANING MAINTENANCE GUIDE 1 To remove water spots or rust spots stainless steel cleaner polish on a cloth is recom...

Page 10: ... Nut SS 13 7013 210 001 1 4 Y Strainer Bottle Filler 3 7014 007 001 Channel and Valve Assembly 14 7013 020 000 5 8 OD Grommet 4 0316 018 00 10 32 Stn Stl Nut Retainer 15 1895 710 000 1 4 Push in Union Tee 5 7013 027 002 Air Control Valve Assembly 16 7014 006 199 Bottle Filler Frame 6 2150 002 199 1 8 x 10 O D Clear PE Tubing 17 0112 021 000 10 32 x 1 2 S S Hex Btn Hd Screw 7 2169 000 000 1 4 OD LL...