ICE 900 Supplemental Service Manual
Page 38 Revision 3-19-2019
5.
Attach a 3/8” hose from the Hot
Water Flush Valve. Hose to be long
enough to drain water into the drain
or bucket.
6.
Open Hot Flush by turning the flush valve counter clockwise.
7.
Turn “DRAIN” valve
“ON” and drain the
water in the Hot Tank.
8.
Catch water from the Hot Tank Flushing Valve in a bucket or
drain. Re-fill and drain the ambient water tank for 2-3 times
to complete the flushing of the Hot Water System.
NOTE:
Systems LED’s on the front panel will continuously and flash and the ICE 900 will sound
while the “DRAIN” switch is in the ON position.
9.
Add one capful of household bleach to the inside of the
Ambient Tank.
CAUTION!
Always ensure proper ventilation and use proper personal protective equipment
such as gloves and eye protection when using chemicals. Refer to Material Safety Data Sheet for
specific requirements of each chemical product. Take all necessary precautions to prevent
sanitizer from contacting eyes, clothing, and any other surfaces in could damage (carpets).
10.
Fill Ambient Tank with Water. Do not fill past the “fill line” or
the Overflow Sensor will shut down the system. If this occurs,
see the Troubleshooting section addressing.
3/8” Hose
Change DRAIN
Switch to “ON”
“DRAIN” Label