Page 29 ‐ Revision: 11‐2‐2018
CAUTION!
WEAR SAFETY GLOVES.
Wear safety gloves when handling the machine. Metal edges are sharp and touching them could
result in a minor moderate injury.
1.
Fill the ice bath until indicated full in the sight tube on back of unit.
2.
Attach the water supply line to the 3/8” supply water (feed water) inlet bulkhead fitting on the
back of the
BLUPURA
Water Treatment System.
Waterlogic
requires the use of a water
pressure regulator. Input or feed pressure must be 14.5 psi to 51 psi (.10 MPa – 0.35MPa).
3.
Turn on the water supply and check for leaks.
4.
Connect the power cord to a 120 Volt socket. *The grounding of the unit is a legal
requirement.
5.
Turn on Power Switch at back of unit.
I = ON
6.
Fill the water circuit. Hold a container under the still dispensing faucet, pull cold water knob
until a continuous flow of water is obtained. Once a continuous flow is obtained, release the
dispensing button. Cold tank is now full.
7.
Move the
BLUPURA
Fizz 80
Water Treatment System
into its final operating position. Be sure
that a minimum of 2” clearance is maintained around both sides and the back of the
BLUPURA
Fizz 80
Water Treatment System
.
NOTE:
This is important to allow proper airflow and heat exchange of refrigeration system.
8.
Level
BLUPURA
Water Treatment System
using the adjustable feet to level if necessary. Never
install on incline.
9.
Once water is dispensing from the cold tap, install C0
2
connection. C0
2
pressure should be set
at 60 psi.
10.
Turn on C0
2
supply and draw ½ gallon of water from sparkling tap.
11.
Once the
BLUPURA
Water Treatment System
is at the target temperature(s), sample the
water to ensure water meets expectations and additional rinsing or adjustment is not
required.
12.
Check the
BLUPURA
Water Treatment System
for any leaks. External Leak Protection is
always recommended.