                                                            Page 24 ‐ Revision: 11‐2‐2018 

 

20.

 

System should be chilled about 60 minutes later. 
 

21.

 

Dispense ½ Gallon of water from the sparkling tap, once system is chilled. 
 

22.

 

Allow to refill. 
 

23.

 

Unit is ready for use. 
 

NOTE:

  

Complete Chilling of Ice Bank takes 1‐3 Hours. 

 

INSTALLING OF C02 CYLINDER

 

 

WARNING!   

Always connect C02 gas cylinder to a reducing valve or regulator.  Failure to do so could 
result in an explosion with possible death or injury when the cylinder valve is opened. 
  

WARNING!   

Always secure gas cylinder in upright condition and away from heat.   

 
 

NOTE:

  Installation of C0

2

 cylinder can only be done once the unit is connected to supply water 

(feed water), has power and the ice‐bank tank has been filled. 

24.

 

Connect the cylinder through the pressure regulator to the 
C0

2

 Inlet Pipe. 

 

25.

 

To increase the level of carbonation of the water, adjust the 
screw by turning clockwise increases the level of carbonation.  
We recommend that you do not exceed 4 bar (60 psi) of 
pressure. 

 

 

 

 

 

 

 

 

Summary of Contents for BLUPURA FIZZ 80

Page 1: ...e ips x 3 8 Tube 1 each 4 inch OD Tubing 2 each 3 8 Quick Connect Connector 1 each 3 8 x quick Connect 1 each Water Shutoff Valve 1 each CO2 Regulator 3 each 10 Coils Water Tubing Blue 3 8 3 each 10 C...

Page 2: ...OVES Wear safety gloves when handling the machine Metal edges are sharp and touching them could result in a minor moderate injury UNPACKING 1 Remove the two straps securing unit to pallet 2 Lift the i...

Page 3: ...on Each Change of filters After system has been inoperative of 5 days or more 8 Turn off incoming feed water if connected 9 Remove Filter Cartridge if connected 10 Mix gallon of sanitizer per directio...

Page 4: ...th supply water feed water 16 Stop filling the Ice Bank once you reach the maximum level on the Ice Bank level tube NOTE If the Ice Bank has been overfilled water will come up through the Drip Tray NO...

Page 5: ...TION CAUTION WATER PRESSURE Input or feed pressure must be 14 5 psi to 51 psi 10 MPa 0 35MPa Be aware of any potential pressure surges caused by building municipal pumping stations Water block devices...

Page 6: ...could result in an explosion with possible death or injury when the cylinder valve is opened WARNING Always secure gas cylinder in upright condition and away from heat NOTE Installation of C02 cylind...

Page 7: ...ace receptacle beneath Tap to catch dispensed water 28 Allow water to run continuously until flow is clear of air NOTE The water will flow flat at first then gradually become more sparkling as the lin...

Page 8: ...h filter change replace filter Cleaning Internal Components Every sanitization and cartridge change Remove accumulation of dust sand or other particulates with a disposable cloth Cleaning of Refrigera...

Page 9: ...WARNING STORE UNIT EMPTY ALWAYS SANITIZE BEFORE REUSE The unit must be completely drained and sealed before storing to avoid stagnation and reduce microbial growth Drain the BLUPURA Water Treatment Sy...

Page 10: ...UNIT IS HEAVY TWO PERSON LIFT REQUIRED Transport unit empty and always use material handling equipment or two people with proper lifting technique to reduce injury risk WARNING STORE AND TRANSPORT UNI...

Page 11: ...water knob until a continuous flow of water is obtained Once a continuous flow is obtained release the dispensing button Cold tank is now full 7 Move the BLUPURA Fizz 80 Water Treatment System into it...

Reviews: