ARAMARK Manual
Page 14 – Revision 10-31-21
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Disconnect before removing UV Lamp.
CAUTION!
UV LAMPS ARE HAZARDOUS.
Lamps are considered Hazardous Waste and must
be disposed of accordingly. Refer to Product MSDS sheet for details.
3.
Clean the quartz sleeve that surrounds the UV lamp with a non-abrasive cloth, descaling solution,
or ultrasonic bath if needed when changing UV lamps.
CAUTION!
UV SYSTEM IS FRAGILE.
Never handle the UV lamp or Quartz Sleeve with bare
hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure proper
operation. Use a soft non-abrasive cloth to clean.
4.
Inspect the Quartz Sleeve O-ring for wear or damage and replace as necessary.
5.
Ensure there is adequate (minimum of 2”) clearance around the Aramark Countertop or Refresh
Center and clean the condenser grill and compressor fan to provide efficient cooling system
operation.
6.
Sanitize the cold tank per instructions in the pre-installation procedures.
7.
Clean and sanitize external surfaces of the Aramark Countertop or Refresh Center. Use soap and
water or chemicals that are compatible with ABS plastic and will not damage or degrade the
product surfaces.
8.
Remove and clean the Faucet. Replace as needed.
WARNING!
SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS.
Use of proper personal
protective equipment such as rubber gloves and eye protection is required.