URINAL INITIAL SET-UP
1. After urinal is installed, test
for water tightness by pouring
a bucket of water into the open
drain hole of urinal. If no water
leak is detected, caulk around the
urinal, leaving approx. 8” on the
bottom of the urinal uncaulked.
Wipe urinal clean.
TROUBLESHOOTING
PROBLEM CAUSE
REMEDY
There is an odor coming
1. ) BlueSeal® is depleted.
If odor comes from urinal trap, add BlueSeal®.
from the urinal.
2. ) EcoTrap
®
is not seated below rim.
Push EcoTrap
®
down below rim.
3. ) Urinal is not connected properly to the drain.
If odor comes from below urinal, remove and reset
urinal to wall and drain line.
Also check floor drain if odor comes from here; if so,
add 1 gal of water to floor drain and add 3 oz. of
EverPrime™
, our great floor drain sealer.
Trap does not flush/flow.
1. ) The EcoTrap
®
is full.
Replace the EcoTrap
®
per Maintenance Instructions.
2. ) The drain line is plugged.
Remove the EcoTrap
®
and snake the drainline.
3. ) The system is double trapped.
Remove the drain line trap so that only the EcoTrap® is
the trap for the system.
EcoTrap® Principle
a. Urine flows down into the
patented Vertical
EcoTrap®
drain insert.
b. In the
EcoTrap®
the urine
passes through a floating
layer of
BlueSeal®
liquid, which
forms a barrier that prevents
sewer vapors from escaping
into the restroom atmosphere.
c. Urine under the barrier layer
overflows into the central
tube and runs down into the
conventional drain line.
2. Take supplied
EcoTrap
® and fill
with water under faucet in sink.
Fill until full or water overflows
on bottom.
3. Insert the water filled
EcoTrap®
into the urinal drain opening .
IMPORTANT: then press
EcoTrap®
by hand below rim.
4. Insert and tighten Portion-Aid
measuring device onto
BlueSeal®
quart bottle. Hold bottle upright.
Squeeze bottle to fill Portion-Aid
to 3oz. Then simply pour
BlueSeal®
from Portion-Aid into
EcoTrap®.
Done!
How it Works!
EcoTrap®
Insert
below rim.
© Waterless Co. Inc. 0118