background image

URINAL INITIAL SET-UP

1. After urinal is installed, test 

for water tightness by pouring 

a bucket of water into the open 

drain hole of urinal. If no water 

leak is detected, caulk around the 

urinal, leaving approx. 8” on the 

bottom of the urinal uncaulked.

Wipe urinal clean.

TROUBLESHOOTING

PROBLEM CAUSE 

REMEDY

There is an odor coming 

1. ) BlueSeal® is depleted. 

If odor comes from urinal trap, add BlueSeal®.

from the urinal. 

2. ) EcoTrap

®

 is not seated below rim. 

Push EcoTrap

®

 down below rim.

 

3. ) Urinal is not connected properly to the drain. 

If odor comes from below urinal, remove and reset

 

 

urinal to wall and drain line.

 

 

Also check floor drain if odor comes from here; if so,  

 

 

 

add 1 gal of water to floor drain and add 3 oz. of

  

EverPrime™

, our great floor drain sealer.

Trap does not flush/flow. 

1. ) The EcoTrap

®

 is full. 

Replace the EcoTrap

®

 per Maintenance Instructions.

 

2. ) The drain line is plugged. 

Remove the EcoTrap

®

 and snake the drainline.

 

 

3. ) The system is double trapped. 

Remove the drain line trap so that only the EcoTrap®  is   

  

the trap for the system.

EcoTrap® Principle

a.  Urine flows down into the

 

patented Vertical 

EcoTrap®

 

drain insert.

b.  In the 

EcoTrap®

 the urine 

 

passes through a floating 

 

layer of

 BlueSeal®

 liquid, which

 

forms a barrier that prevents

 

sewer vapors from escaping

 

into the restroom atmosphere.

c.  Urine under the barrier layer

 

overflows into the central 

 

tube and runs down into the

 

conventional drain line.

2. Take supplied

 EcoTrap

® and fill 

with water under faucet in sink. 

Fill until full or water overflows 

on bottom.

3. Insert the water filled 

EcoTrap® 

into the urinal drain opening . 

IMPORTANT: then press 

EcoTrap®

 

by hand below rim.

4. Insert and tighten Portion-Aid 

measuring device onto 

BlueSeal®

 

quart bottle. Hold bottle upright.

Squeeze bottle to fill Portion-Aid 

to 3oz. Then simply pour 

BlueSeal®

 

from Portion-Aid into 

EcoTrap®.

 

Done!

How it Works!

EcoTrap®

Insert 

below rim.

© Waterless Co. Inc. 0118

Summary of Contents for Del Mar 2901

Page 1: ...less Co reserves the right to change product specifications at any time without notice It is the responsibility of the specifier installer and wholesale seller to confirm specification at time of sale...

Page 2: ...l hangers with supplied screws and plastic anchors Tighten screws Mark holes on wall through holes in horizontal bottom piece of urinal Remove urinal and use same drill bit to drill holes Reattach uri...

Page 3: ...5 356MM 14 0 25MM 1 0 356MM 14 0 495MM 19 5 381MM 15 0 50MM 2 0 102MM 4 0 102MM 4 0 updat ed 10 03 2011 610 MM 24 0 TO FLOOR ADA 432 MM 17 0 TO FLOOR FOR STANDARD INSTALLATION Mount at 24 above finish...

Page 4: ...ons 2 The drain line is plugged Remove the EcoTrap and snake the drainline 3 The system is double trapped Remove the drain line trap so that only the EcoTrap is the trap for the system EcoTrap Princip...

Page 5: ...surfaces for cleaning 3 Use cleaner on wet sponge cloth or mop Then wipe clean all surfaces of urinal especially the lower front 4 Dry all surfaces with a soft cloth or soft rag Cleaning Instructions...

Page 6: ...and remove X Traptor 6 Seal the plastic bag and discard in locally appropriate manner 7 Loosen any sediment accumulation in drain hole with any long object 8 Pour a full bucket approx 5 gallons of pr...

Page 7: ...accidents acts of God misuse unauthorized repairs negligence modifications tampering disconnection improper adjustments improper care or maintenance im proper installation and out of warranty service...

Page 8: ...__________ Fax ____ ______________E Mail ______________________Purchased From __________________________ Model 2003__2004___2005___2104___2902___2903___Other_____________Purchase Date _________ Instal...