Section 6: Trouble Shooting Guide

 

 

Problem 

 

 

Possible Cause 

 

  

 

Solution 

 

Low or Declining                  

Water supply valve closed.   

           Open valve. 

Permeate Production

 

Crimped poly product line 

 

 

Repair or replace tube 

Raw water TDS too high 

Consult dealer – may 

need pre-treatment. 

Membranes fouled. 

Clean or replace 

membrane. 

   

Fast flush system. 

 

Feed water content has changed. 

Review pre-treatment. 

 

Pre-treatment cartridges plugged. 

Replace cartridges. 

 

Leaking Joints

 

Fittings not seated.   

 

 

Disconnect fitting  

   

 

 

 

 

 

and reseat tube. 

 

Filter housing leaking.  

Tighten with housing 

wrench. 

 

Inspect o-rings for cuts 

or crimps. 

 

Low System Pressure         

Clogged pre-filters.   

 

 

Replace pre-filter  

 

 

 

 

 

 

 

cartridges. 

Low feed water pressure. 

Check feed water 

source for restrictions. 

Malfunctioning pressure gauge. 

Replace gauge. 

 

High System Pressure 

Plugged or restricted concentrate orifice       Clean or replace valve 

 

and/or recirculation valves.   

 

or orifice. 

 

Crimped concentrate or product line.  

Repair or replace tube. 

Malfunctioning pressure gauge. 

 

Replace gauge. 

 

Permeate TDS Rising 

Scaled or fouled membranes.  

 

Replace membranes. 

 

 

 

 

 

 

 

Fast flush membrane. 

 

Pre-treatment system failure.  

 

Check feed water  

 

 

 

 

 

 

 

 

 

 

quality. 

 

 

 

 

 

Section 6: Common Replacement Parts

 

 

Part Description 

Part Number 

Excelpure 10” 5 Micron PP Filter Cartridge 

PP10B05 

Excelpure 20” Carbon Block Filter Cartridge 

CBC10B 

Auto Shutoff Valve 

ASV3800 

Pressure Gauge, 0-100 psi 

AG06 

Pre-filter Housing Wrench 

HAN13W 

Orifice Plate 

5865071 

Black Max 400GPD Membrane ULP TFC 

BME3013SXL 

 

Summary of Contents for Vectapure RSXII LITE

Page 1: ...SES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL...

Page 2: ...taminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Vectapure RSXII Lite RO system use Vectapure RSXII Lite systems use two stages of tre...

Page 3: ...ak usage of water for the combined equipment does not exceed the output of your RO system or its product water storage See your dealer for advice and parts Q What factors affect the quantity and the q...

Page 4: ...orating and is losing its effectiveness Where the RO is used as a pre treatment for a process requiring water to exact standards you should adopt a regular ongoing sampling and testing procedure to en...

Page 5: ...e Pre treatment by carbon filtration is very effective for chlorine reduction carbon eventually becomes exhausted and must be replaced to ensure continuous filtration If stabilized chlorine is present...

Page 6: ...eation Fouling may occur as layers of deposition on the surface of the membrane cake fouling a hardened layer on the membrane surface scale particle insertion into the pore channel or entrance pore bl...

Page 7: ...lorine 1 ppm Permanent membrane damage Increased salt passage Carbon Filter CF Series Excelclear Carbon pH 5 5 9 5 Internal corrosion Lime scaling in equipment Plumbing damage Replace water source Adj...

Page 8: ...itized before use and periodically disinfected RO product water will have no chlorine residual and will be subject to contamination at all stages in the plumbing system Consider UV disinfection as an...

Page 9: ...s TDS Monitor Reject flow meter Permeate flow meter 1 4 Drain Connection membrane housings Auto Shut Off Valve 3 8 Feed Water inlet 3 8 Permeate Outlet Housing 5 micron Pre Filter Levelling feet Figur...

Page 10: ...on the drain line over the drain and secure it in place Do not elevate the drain line over 10 feet from the floor If connection to a sewer line is necessary check the local code or a plumbing professi...

Page 11: ...1000 to 2000 Orifice colour codes are as follows 500 TDS Black 501 1000 TDS Lilac Make sure that you have the correct orifice plate fitted to your system This orifice has been selected to operate at...

Page 12: ...ILL CAUSE PREMATURE MEMBRANE FAILURE OR INTERNAL SCALING AND EQUIPMENT FAILURE Section 5 System Maintenance Changing Pre filter Cartridges The pre filter cartridges should be changed as a rule of thum...

Page 13: ...eter to verify the initial reading The membrane element life will range from 1 to 5 years depending on the quality of the raw water See S 3 7 2 for membrane removal and installation instructions If yo...

Page 14: ...pre filter cartridges Low feed water pressure Check feed water source for restrictions Malfunctioning pressure gauge Replace gauge High System Pressure Plugged or restricted concentrate orifice Clean...

Page 15: ...14 Section 7 VectapureTM RSXII Lite Performance Log Date Line System Permeate Feed Water Pre Filter Fast Permeate Waste Pressure Pressure TDS TDS Change Flush Flow Meter Flow Meter...

Page 16: ...15 Date Line System Permeate Feed Water Pre Filter Fast Permeate Waste Pressure Pressure TDS TDS Change Flush Flow Meter Flow Meter...

Page 17: ...e An RSXII Lite has 2 membranes each nominally rated at 400 gpd and the raw water temperature is 9 0 degrees Celsius 2x400 2 350 gpd Temperature Corrected Of course the actual production of your syste...

Page 18: ...17 THIS PAGE HAS BEEN LEFT BLANK INTENTIONALLY...

Page 19: ...18 THIS PAGE HAS BEEN LEFT BLANK INTENTIONALLY...

Page 20: ...19 WATERITE INC Winnipeg Manitoba Canada www waterite com...

Reviews: