CYCLE SETTING LIMITS
CYCLE OPTIONS
UNITS
LOWER/UPPER LIMIT
DEFAULT
Backwash
minutes
1 to 1200
8
Rinse (fast rinse)
6
dn Brine (brine and slow rinse)
60
UP Brine (brine and slow rinse)
60
Fill (regenerant tank refill)
Lbs.
0.1 to 120.0
60
Service
minutes
1 to 1200
240
SOFTENER SYSTEM SETUP
In SOFTENER SYSTEM SETUP you choose the duration for the cycles selected in CYCLE SEQUENCE and specify
other operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as
follows:
Since no time is associated with the END cycle,
the END cycle will not appear in the SOFTENER
SYSTEM SETUP sequence.
Note: Fill is in pounds of salt.
Step 1S – Press NEXT and simultaneously for 3 seconds and release. If screen in Step 2S
does not appear in 5 seconds the lock on the valve is activated. To unlock press
, NEXT,
, and SET CLOCK in sequence, then press NEXT and
simultaneously for 3 seconds
and release.
Step 2S – Choose SOFTENING using the
or
button. Press NEXT to go to Step 3S.
Press REGEN if you want to exit SOFTENER SYSTEM SETUP.
Step 3S – Select the time for the first cycle (which in this example is BACKWASH) using
the
or
button.
Press NEXT to go to Step 4S.
Press REGEN if you need to return to previous step.
Step 4S – Select the time for the second cycle (which in this example is dn BRINE) using
the
or
button.
Press NEXT to go to Step 5S.
Press REGEN if you need to return to previous step.
NOTE: The display will flash between cycle number and time, and brine direction (dn or
UP).
Step 5S – Select the time for the third cycle (which in this example is RINSE) using the
or
button.
Press NEXT to go to Step 6S.
Press REGEN if you need to return to the previous step.
Step 6S – Select the Lbs. for the fourth cycle (which in this example is FILL) using the
or
button. Press NEXT to go to Step 7S. Press REGEN if you need to return to the previous step.
Step 7S – Set Grains Capacity using the
or
button. The ion exchange capacity is in
grains of hardness as calcium carbonate for the system based on the pounds of salt that will
be used. Calculate the pounds of salt using the fill time previously selected. The allowable
grains capacity range varies from 5000 to 200,000 grains. The increment in- crease is 500 for
the range from 5000 to 30,000, 1000 for the range of 30,000 to 100,000, and 2000 for the
range of 100,000 to 200,000. Grains capacity is affected by the fill time. The grains capacity
for the selected fill time should be confirmed by testing. The capacity and hardness levels
entered are used to automatically calculate reserve capacity when gallon capacity is set to
AUTO. Press NEXT to go to Step 8S.
Press REGEN if you need to return to previous step.