Digital Display 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1

 

Numeric Display of Voltage (Mostly), Parameter Setting such as Battery Type and Time Switch Parameters

 

D2

  Indication for a Solar Panel. Indicates that a Solar PV Panel is connected to the Controller. No Solar PV Panel Symbol 

Indicator, means that the Solar Panel is either Not Connected or the Solar PV Panel is not receiving Sun Light

 

D3  Charging Indicator 

 This Symbol indicates that the Solar PV Panel is charging the battery. If this indicator is not visible, 

this means that the battery voltage is too low for charging. If the Indicator Flickers, then the Battery is charged and in 
Floating State.  

D4  The bars in the battery indicator, provide a sense on how much charge your battery has. Zero Bars 

 Battery has no 

Charge, 5 Bars the battery is fully charged, use this in conjunction with D3 and check whether the battery is in Floating 
Charge State. 

D5  Battery Discharge Indicator 

D6     Load ON / OFF 

D7    Amp / Hrs 

D8    Volts 

Charge Controller Buttons 

Configure your Charge Controller for Use 

Display and Understanding the use of the Buttons on the faceplate of your Charge controller 

There are two buttons on the faceplate of your Charge Controller, namely the Left-Hand Side Button (LHS-B) (sometimes 
referred to as the Menu Button and the Right-Hand Side Button (RHS-B)

 

Left Hand Side Button (LHS-B) 

4 functions 

 Menu and Select (enter programming mode) / and Change Setting / Deselect (Exit Programming Mode) 

D1 

D2 

D3 

D4 

D5 

D6 

D7 

D8 

Summary of Contents for FL-800

Page 1: ...Page 1 of 12 Continuous Use Amphibious 12v DC Pump and Solar Kit Installation Instruction Booklet...

Page 2: ...Placement and Volt Drop 4 Mounting Structures 4 Solar Charge Controller 4 Features of the Charge Controller 5 System Connection 5 Fuses 5 Digital Display 6 Charge Controller Buttons 6 Configure your C...

Page 3: ...ents 1 2 1 X Solar Panel 50 Watt 2 3 1 X 12 Volt Gel Acid Battery P N 12 AH 6 CNF 12 3 1 X PWM Solar Charge Controller 4 1 X 12 Volt Continuous Use Amphibious Pump P N FL 800 5 1 X length of Red and B...

Page 4: ...omised use an Average Inclination 35 to 45 degrees Static Placement and Volt Drop Try to keep all the Kit components as close together as possible As the distance increases between components so shoul...

Page 5: ...orrectly Red is Positive and Black is Negative Even if certain suppliers use different colours one should by deduction determine which wires and connection points are or Positive of negative Make sure...

Page 6: ...g State D4 The bars in the battery indicator provide a sense on how much charge your battery has Zero Bars Battery has no Charge 5 Bars the battery is fully charged use this in conjunction with D3 and...

Page 7: ...entally upwardly The Right Button Does the opposite 3 Selection Function To enter programming mode 4 To exit programming mode if a setting has been changed the new setting will be saved or if no setti...

Page 8: ...e battery charging for about a day of two Always switch off your load as described in 1 1 of this table when you are bringing your battery s up to a serviceable level The little lamp bulb Icon will di...

Page 9: ...nd Side Button one press at a time increments the setting one decimal digit at a time Pressing the Right Hand Side Button one press at a time Decrements the setting parameter one decimal digit at a ti...

Page 10: ...after the amount of the set hours has elapsed 0 H represents Light Control Mode Load will switch ON after darkness Sunset and then the Load will be switched OFF at dawn Sunrise Hold the Left Hand Sid...

Page 11: ...ickly enough Check Panel Direction Should be True Northerly Direction Use Google Maps to orientate your property to the direction north is the top of the Map Your Panel is in the shade Your Panel is i...

Page 12: ...ch does not allow air or and Air Water mixture 8 It is always best to have a position in the pool pond or fountain which allows a secure immoveable positioning of the pump 9 The suction should not dra...