background image

IMPORTANT WARNING - PLEASE READ

System Flushing:

This reverse osmosis system contains a preservative solution to prevent

microbiological  growth  and  freezing  which  if  ingested  may  cause  irritation  of  the
gastrointestinal  tract,  colic,  diarrhea  or  other  symptoms.  Therefore,  approximately  5
gallons of water must be drawn from the tap to flush out the preservative solution before
using the system. This volume of water represents approximately two days of production.
The water flushed should be disposed of to the drain.

Feed WaterQuality:

This  reverse  osmosis  drinking  water  system  is  not  intended  to  be

used for the treatment of water that is microbiologically unsafe or of unknown quality. If
the  feed  water  quality  is  unsafe  or  unknown,  have  a  sample  of  the  water  tested  by  a
qualified  laboratory  or  agency  and  implement  the  necessary  measures  to  ensure  a  safe
water supply.

Summary of Contents for E75TFC-3

Page 1: ...Reverse Osmosis Drinking Water System Installation Operation and Service Manual 90012 Rev 06 05 June November 2005...

Page 2: ......

Page 3: ...h out the preservative solution before using the system This volume of water represents approximately two days of production The water flushed should be disposed of to the drain Feed Water Quality Thi...

Page 4: ...ied items checklist 3 Installation 4 Startup and Operation 9 Maintenance 10 Sanitization Procedures 11 Maintenance Schedule 14 Parts List and Drawing for E75TFC 3SF E50TFC 3SF 15 Parts List and Drawin...

Page 5: ...om the tap Ice Cubes use RO water to fill ice cube trays Ice cubes made from RO water are typically clearer and better tasting than ice made from plain tap water Automatic Ice Makers a water line from...

Page 6: ...e reverse osmosis membrane The membrane will allow only permeate product water to pass through The brine waste water goes to the drain Permeate then flows through a hydraulic shut off valve to the sto...

Page 7: ...ystem complete with tubing bundle 3 Reverse Osmosis membrane element in sealed protective bag 4 Filter Sump Wrench 5 Length of black tubing 6 Drain line saddle assembly 7 Feed Water saddle valve assem...

Page 8: ...asily removed from under the sink Avoid placing the storage tank in out of the way cabinets or dead spaces There are two reasons for this 1 the difficulty of installation increases significantly and 2...

Page 9: ...check for any signs of leaks f When ready to supply water to the system turn valve handle counter clockwise until fully open Feed Water Assembly Installation of Drain Saddle Assembly The system comes...

Page 10: ...ap other than the one serving the garbage disposal Before making a connection as shown in Figure 5 please check with code authorities Figure 5 Drain Saddle Assembly Figure 6 Recommended Drain Saddle C...

Page 11: ...sharp edges f Immediately clean up the sink area NOTE If an enamel or porcelain sink is encountered it is very important that the layer of porcelain be removed before following the steps outlined abo...

Page 12: ...hand push the membrane all the way into the housing Important Do not use force and ensure that the membrane is not protruding from the housing 6 Replace the membrane housing end cap and hand tighten 7...

Page 13: ...utlet side of the Pre Carbon Filter to the Auto Shut Off Valve Direct tubing into a pail or catch basin b Turn on the feed water by opening the needle valve on the feed water saddle valve and catch th...

Page 14: ...of hydraulic pressure greater than the osmotic pressure in water containing dissolved solids The life of the membrane can be determined by measuring the percentage of rejection of total dissolved soli...

Page 15: ...mponents DO NOT USE SCOURING PADS OR ANY OTHER TYPE OF INSTRUMENT THAT COULD POTENTIALLY SCRATCH THE SURFACES OF THE UNIT Measuring spoon or device Household bleach typically containing 5 25 of chlori...

Page 16: ...SURFACE Unless the membrane element is being replaced at this time then discard the old membrane STEP 4 OPEN THE FILTER SUMPS WITH THE SUMP WRENCH SUPPLIED AND REMOVE THE CARTRIDGES STEP 5 CLEAN THE...

Page 17: ...LVE STEP 10 ALLOW THE SYSTEM TO SIT WITH THE DILUTED SANITIZING SOLUTION FOR APPROXIMATELY 20 MINUTES STEP 11 OPEN THE FAUCET AND PURGE THE TANK AND SYSTEM OF THE SANITIZING SOLUTION STEP 12 REINSTALL...

Page 18: ...edure Carbon Sediment 5 micron Sediment Carbon Cartridge 35 50 or 75 USGPD refer to Dual Cartridge Cartridge Rated Membrane instructions 2 sump models only 3 sump models 3 sump models x2 refer to mode...

Page 19: ...404 14 Tee 3 8 x 1 4 npt 92403 16 Membrane RO 50 GPD TFC 92035 75 GPD TFC 92022 17 Housing cartridge white black 92026 18 Cartridge pre filter 5 micron 26091 19 Cartridge carbon 26081 20 Saddle drain...

Page 20: ...t 92405 13 Elbow male 3 8 x 1 4 npt 92404 14 Swivel tee male 3 8 x 1 4 npt 92403 15 Connector union 3 8 1 4 92402 16 Membrane RO 35 GPD TFC 92008 17 Housing cartridge white black 92026 18b Cartridge c...

Page 21: ...17 Reverse Osmosis Drinking Water System Flow Diagram all models...

Page 22: ...in feed water TDS Contact dealer for revised product water TDS 3 Membrane life expired Replace membrane Bad tasting water 1 Taste from glass or plastic containers Contact dealer for explanation 2 Post...

Page 23: ...19...

Page 24: ...cteria attack installation or operation contrary to our printed instructions or damage caused by hot water freezing flood fire or Act of God is not covered by this warranty In all such cases regular p...