Installation of Ball Valve Assembly

The ball valve and quick connect adapter must be installed on the RO storage tank.

a.  Put 2-3 wraps of Teflon tape on the storage tank threads, and on the 1/4" x 3/8" male connector.

b.  Install the 1/4" x 3/8" male connector onto the ball valve. Tighten the fitting very gently until it is snug.

Be very careful not to over-tighten or the threads may strip.

c.  Tighten the ball valve assembly onto the RO storage tank. Tighten the fitting very gently until it is snug.

Be very careful not to over-tighten or the threads may strip.

Drilling Sink Hole 

The typical 1-1/8" sink hole will accommodate most standard or air gap spigots. Once the location of the
spigot  has  been  determined,  always  check  below  the  point  you  are  about  to  drill  to  ensure  it  is
unobstructed and that it isn't over a reinforcing rib.

a.  Center punch the desired location to provide a starting point for your drill.

b.  Drill a 1/8" pilot hole.

c.  Enlarge the pilot hole using a 1-1/8" high speed steel hole saw for 

air gap faucet

.

d.  Enlarge the pilot hole using a 9/16" drill bit for standard faucet.

e.  Remove all burrs and sharp edges.

f.  Immediately clean up the sink area.

NOTE:  If  an  enamel  or  porcelain  sink  is  encountered,  it  is  very  important  that  the  layer  of  porcelain  be
removed before following the steps outlined above. This can be accomplished by gently grinding  away,
using  a  hobby  grinder  and  silicon  carbide  wheel,  enough  area  of  porcelain  down  to  the  metal  base  to
accommodate a 1-1/8" high speed steel hole saw. The hole saw cannot contact surrounding porcelain or
chipping can occur. Now the steps outlined above can be followed.

Installation of Air Gap Faucet

1.  Place the chrome washer and the rubber washer on the base of the faucet.

2.  Apply 5-7 wraps of the teflon tape to the bottom of the brass stem. Install 3/8" quick connect faucet

adapter provided. Tighten gently until fitting is snug. Be careful not to over-tighten as the threads may

strip.

3.  Attach the 1/4" brine water discharge line to the brine input (small) barb and 1/4" or 3/8" drain line to

the brine output (large) barb.

4.  Mount the faucet and complete assembly.

Note: Before connections are made, tubing should be cut to ensure a neat and orderly installation. The
storage tank and spigot tubes should be as short as possible so that the greatest possible flow can be
obtained from the spigot.

Ball Valve

Tank

3/8 Tubing

Adapter

Figure 7 - Pressure Tank Shutoff Valve

Summary of Contents for E75TFC-3

Page 1: ...Reverse Osmosis Drinking Water System Installation Operation and Service Manual 90012 Rev 06 05 June November 2005...

Page 2: ......

Page 3: ...h out the preservative solution before using the system This volume of water represents approximately two days of production The water flushed should be disposed of to the drain Feed Water Quality Thi...

Page 4: ...ied items checklist 3 Installation 4 Startup and Operation 9 Maintenance 10 Sanitization Procedures 11 Maintenance Schedule 14 Parts List and Drawing for E75TFC 3SF E50TFC 3SF 15 Parts List and Drawin...

Page 5: ...om the tap Ice Cubes use RO water to fill ice cube trays Ice cubes made from RO water are typically clearer and better tasting than ice made from plain tap water Automatic Ice Makers a water line from...

Page 6: ...e reverse osmosis membrane The membrane will allow only permeate product water to pass through The brine waste water goes to the drain Permeate then flows through a hydraulic shut off valve to the sto...

Page 7: ...ystem complete with tubing bundle 3 Reverse Osmosis membrane element in sealed protective bag 4 Filter Sump Wrench 5 Length of black tubing 6 Drain line saddle assembly 7 Feed Water saddle valve assem...

Page 8: ...asily removed from under the sink Avoid placing the storage tank in out of the way cabinets or dead spaces There are two reasons for this 1 the difficulty of installation increases significantly and 2...

Page 9: ...check for any signs of leaks f When ready to supply water to the system turn valve handle counter clockwise until fully open Feed Water Assembly Installation of Drain Saddle Assembly The system comes...

Page 10: ...ap other than the one serving the garbage disposal Before making a connection as shown in Figure 5 please check with code authorities Figure 5 Drain Saddle Assembly Figure 6 Recommended Drain Saddle C...

Page 11: ...sharp edges f Immediately clean up the sink area NOTE If an enamel or porcelain sink is encountered it is very important that the layer of porcelain be removed before following the steps outlined abo...

Page 12: ...hand push the membrane all the way into the housing Important Do not use force and ensure that the membrane is not protruding from the housing 6 Replace the membrane housing end cap and hand tighten 7...

Page 13: ...utlet side of the Pre Carbon Filter to the Auto Shut Off Valve Direct tubing into a pail or catch basin b Turn on the feed water by opening the needle valve on the feed water saddle valve and catch th...

Page 14: ...of hydraulic pressure greater than the osmotic pressure in water containing dissolved solids The life of the membrane can be determined by measuring the percentage of rejection of total dissolved soli...

Page 15: ...mponents DO NOT USE SCOURING PADS OR ANY OTHER TYPE OF INSTRUMENT THAT COULD POTENTIALLY SCRATCH THE SURFACES OF THE UNIT Measuring spoon or device Household bleach typically containing 5 25 of chlori...

Page 16: ...SURFACE Unless the membrane element is being replaced at this time then discard the old membrane STEP 4 OPEN THE FILTER SUMPS WITH THE SUMP WRENCH SUPPLIED AND REMOVE THE CARTRIDGES STEP 5 CLEAN THE...

Page 17: ...LVE STEP 10 ALLOW THE SYSTEM TO SIT WITH THE DILUTED SANITIZING SOLUTION FOR APPROXIMATELY 20 MINUTES STEP 11 OPEN THE FAUCET AND PURGE THE TANK AND SYSTEM OF THE SANITIZING SOLUTION STEP 12 REINSTALL...

Page 18: ...edure Carbon Sediment 5 micron Sediment Carbon Cartridge 35 50 or 75 USGPD refer to Dual Cartridge Cartridge Rated Membrane instructions 2 sump models only 3 sump models 3 sump models x2 refer to mode...

Page 19: ...404 14 Tee 3 8 x 1 4 npt 92403 16 Membrane RO 50 GPD TFC 92035 75 GPD TFC 92022 17 Housing cartridge white black 92026 18 Cartridge pre filter 5 micron 26091 19 Cartridge carbon 26081 20 Saddle drain...

Page 20: ...t 92405 13 Elbow male 3 8 x 1 4 npt 92404 14 Swivel tee male 3 8 x 1 4 npt 92403 15 Connector union 3 8 1 4 92402 16 Membrane RO 35 GPD TFC 92008 17 Housing cartridge white black 92026 18b Cartridge c...

Page 21: ...17 Reverse Osmosis Drinking Water System Flow Diagram all models...

Page 22: ...in feed water TDS Contact dealer for revised product water TDS 3 Membrane life expired Replace membrane Bad tasting water 1 Taste from glass or plastic containers Contact dealer for explanation 2 Post...

Page 23: ...19...

Page 24: ...cteria attack installation or operation contrary to our printed instructions or damage caused by hot water freezing flood fire or Act of God is not covered by this warranty In all such cases regular p...

Reviews: