background image

17  

Care of Your System 

To retain the attractive appearance of your new water softener, clean occasionally with mild 

soap solution.  Do not use abrasive cleaners, ammonia or solvents.  Never subject your sof-
tener to freezing or to temperatures above 100°F. 

Resin Cleaner 

An approved resin cleaner must be used on a regular basis if your water supply contains 

iron.  The amount of resin cleaner and frequency of use is determined by the quantity of 
iron in your water (consult your local representative or follow the directions on the resin 

cleaner package). 

Sanitizing Procedure 

Care is taken at the factory to keep your water softener clean and sanitary. Materials used 

to make the softener will not infect or contaminate your water supply, and will not cause 
bacteria to form or grow.  However, during shipping, storage, installing and operating, bac-

teria could get into the softener. For this reason, sanitizing as follows is suggested when in-
stalling. 

 

Sani-System Liquid Sanitizer Concentrate 
 

 
 

 

 
 

 
 

Item# 80030021—Softener Sanitizer 0.25 fl.oz (24 Pack) 

1. Be sure to complete all installation steps, including programming. 
2. For effective and complete sanitization, Sani-System Liquid Sanitizer Concentrate is rec-

ommended.  Pour one 0.25 fl. Oz. package into the brine well located in the cabinet or 
brine tank.  (Alternative use 3/4 oz of common 5.25% household bleach) 

3.  Start an immediate regeneration.  (See page 11) 
4. The Softener Sanitizer Solution is drawn into and through the water softener to sanitize 

it. This sanitizing regeneration is over in about two hours. Then, soft water is available 

for your use. 

NOTE: Sanitizing is recommended by the Water Quality Association for disinfecting. On 

some water supplies, they suggest periodic sanitizing. 

Summary of Contents for 185HEDP

Page 1: ...y before opera on 2 Avoid pinched o rings during installa on by applying provided with install kit NSF cer fied lubri cant to all seals 3 This system is not intended for trea ng water that is microbio...

Page 2: ...treating water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to mini...

Page 3: ...Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night t...

Page 4: ...rate may affect capacity and efficiency performance The manufacturer reserves the right to make product improvements which may deviate from the specifications and Specifica ons WG185HEDP 100 WG185HED...

Page 5: ...ot covered by the war ranty Put the softener in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to...

Page 6: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This...

Page 7: ...7 Installation...

Page 8: ...or the full amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve...

Page 9: ...daily use and the reserve ca pacity of the system SALT SETTING There are 3 settings to choose in the MENU SET TINGS These settings will determine the salt dosage and capacity for the system For SIM un...

Page 10: ...of the parallel tank adaptor used in our dual tank products i e BIF BAF HTO HEDP etc has been redeveloped This new shorter version will also change the New flow directions OUT IN New Style Parallel T...

Page 11: ...flows upwards in the tank 2 regenerating the media bed It then travels to tank 1 through the center of the distribution tube and flows upwards in tank 1 and then out to the drain Settle Rinse During...

Page 12: ...ll pause on the Date and Time page for 5 seconds Then it will continually scroll through all of the system diagnostic display pages Depending on the Valve Type some pages will not be dis played To man...

Page 13: ...70 of the required fresh water is added in Step 5 in the previ ous regenera on The default brine making me is 30 minutes 2 Brine The brine solu on is introduced slowly to the bo om of the tank flowin...

Page 14: ...Use only crystal water softener salt Check the salt level monthly It is important to main tain the salt level above the water level To add salt simply lift the salt lid and add the salt directly into...

Page 15: ...ontrol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Re...

Page 16: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Page 17: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Page 18: ...18 Brine Tank Res Up Feeder Assembly Optional Step 3 Install brine well Feed wick from feeder into the opening in the brine well cap...

Page 19: ...19 Main Repair Parts Connectors A A A B D F E A C...

Page 20: ...STON ASSEMBLY 60010035 INJECTOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032...

Page 21: ...A19 1 5030013 O Ring 30 2 65 A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A2...

Page 22: ...22 Power Head Exploded View...

Page 23: ...3000426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT85 Mounting B11 1 5031009 BNT85HE Brine Gear Upflow B12 1 5010023 Magnet 3 2 7 B13 1 505614...

Page 24: ...24 Trouble Shooting...

Page 25: ...t mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifications and n...

Reviews: