background image

11 

 

 

CLEANING, SANITIZING, AND CARTRIDGE REPLACEMENT PROCEDURE

 

 

19. 

CAUTION:

  Do not remove protective plastic bag from 

replacement filter/membrane cartridges until so  

 

instructed.  

 

Install "O" rings into filter housings.  Open top of filter 
bag enough to expose filter cap and "O" ring grooves. 
Place a small amount of "O" ring lubricant on surface 
of each "O" ring. 

 
20. 

CAUTION: 

Tighten filter housings by hand only.  Do  

 

not use tools as they will over-tighten and damage  

 

housings.  Take care not to cut or pinch o-rings. 

 

CAUTION: 

Refer to Figure 8 for location of each  

 

cartridge.   

 

Install filter and membrane cartridges. Hold cartridge 
by its protective plastic bag and insert cartridge into 
manifold turning it 1/4 turn as it enters the port. Slide 
bag from cartridge and discard. Replace each filter 
housing as each cartridge is installed. 

 
21.  Turn feed water valve slowly to open position. 
 
22.  Confirm system is producing water. Unit will be 

sending rinse water to drain. 

 

Optional Smartap Water Quality Monitor 

TO REPLACE BATTERY:  Perform Steps 23 – 29  

NOTE:

  Replace battery with a new alkaline 9-volt battery. 

  
23. 

CAUTION:

  Wiring within module cover connects 

monitor components.  If wires, circuit board, or 
connections are damaged and/or wetted, monitor will  

 

not function.   

 

Remove module cover by gently lifting manifold cover 
up and away from manifold body. 

 
24.  Disconnect battery. The battery connection is a snap 

type connector (Figure 9). 

 
25.  Remove battery by sliding it out of its holder. 
 
26.  Slide new battery into its holder. 
 
27. 

CAUTION: 

Verify battery connector alignment  

 

before making connection (Figure 9). 

 

Connect battery by pressing clip onto battery 
terminals. 

 

NOTE: 

Release button immediately after light  

illuminates. Test is to confirm battery connection,  
not water quality.

  

 

28.  Test battery connection by activating monitor. Press 

push button. If an indicator light illuminates, 
connection is good.   

 
29.  Replace manifold cover by gently pushing manifold 

cover onto manifold until it snaps into place. 

 
30.  Open product water faucet.  Let water flow until all 

air has been expelled from the system. 

 
31.  Close product water faucet.  Wait 30 minutes, check  
 

connections for leaks, and correct if necessary. 

 
 

Icemaker/Extra point of use: Check lines for leaks. 

 
32.  Allow storage tank to fill overnight.  

 

33. 

WARNING:  DO NOT USE THE FIRST FULL  

 

STORAGE TANK OF WATER 

 

Discard (to drain) first full tank of water by opening 
product water faucet until water flow stops, then 
close faucet.  This flushes sanitizing solution from  

 

system. 

 

Icemaker:  Let tray/bin fill with ice cubes.  Discard all 
ice cubes to drain.  This flushes sanitizing solution 
from lines to icemaker.  Replace delivery device filter 
(if applicable). 

 
34.  System is ready to use.  Should there be any after 

taste or odor, drain storage tank and repeat Steps 
32 and 33. 

 

 

Figure 9:

 Smartap

®

 Battery Connections 

 

DO NOT USE THE FIRST  

FULL STORAGE TANK OF WATER

 

Allow reservoir to fill overnight.   

Dispense this water to drain.   

This process removes sanitizing solution from system, 

sanitizes fittings and tubing, and sends solution to drain. 

Summary of Contents for 12403 series

Page 1: ...ested and certified by WQA against NSF ANSI 58 for the reduction of TDS Tested and Certified by WQA against ORD0902 for lead free compliance 4VTFC09G PB 4VTFC50G PB 4VTFC25G PB 4VTFC75G PB WQA Tested...

Page 2: ...on and retain for reference Unit Model Number _________________________________ Serial Number _____________________________________ Date Purchased ____________________________________ Date Installed _...

Page 3: ...f this system The use of saddle piercing valves is not permitted The water produced by the reverse osmosis RO process can be used for many purposes around the home o Drinking Water keep a container of...

Page 4: ...ers to reverse osmosis membranes constructed from a THIN FILM COMPOSITE 2 The daily production rate is the volume of product water produced by the system per day and is determined by testing in accord...

Page 5: ...ICTOR TUBING 6 Flow Restrictor Tubing 9 GPD 25 GPD 50 GPD 75 GPD 40600034 40600040 40600041 40600042 PRODUCT WATER FAUCETS Item Description Part No 7 8 Chrome Plated Metal Air Gap Connector Faucet 3 8...

Page 6: ...ER STORAGE TANKS ALL SYSTEMS Item Description Part No 1 2 3 4 Storage Tank Assembly Polymer Storage Tank Assembly Metal Ball Valve 3 8 Steel Tank Ball Valve 3 8 Plastic Tank Insert 3 8 92313 92342 922...

Page 7: ...consideration are access to cold water supply line and household sink drainpipe Specific requirements are detailed in Table 3 COMPONENT LOCATION REQUIREMENTS Table 3 PRODUCT WATER FAUCET Faucet may b...

Page 8: ...readings are obtained when the system is making water for at least 10 minutes The customer can also contact the local dealer for water sampling service or kit INTER COMPONENT CONNECTIONS Connections b...

Page 9: ...4 Connect source water feed tubing to valve body using compression fitting a Slide nut and sleeve onto tubing in that order b Install insert into plastic tubing c Install tube with insert and sleeve...

Page 10: ...tem 1 on drainpipe Allow adequate space for drilling operation 3 Tighten saddle bolts evenly on both sides Avoid over tightening 4 Using opening in drain saddle outlet as a guide drill a 3 8 to 7 16 d...

Page 11: ...re pilot guide is inserted tightly Insert pilot guide into pilot hole Push down gently on drill motor to apply light pressure to porcelain surface Start drill motor turning as slowly as possible After...

Page 12: ...hown 8 CAUTION Red 3 8 tube connecting product water faucet to drain saddle must run vertically or as closely as possible with no sharp bends or loops See Figure 4 Connect loose ends of tubing as foll...

Page 13: ...not available in California 92192 1 2 3 4 5 6 7 8 Body Faucet Faucet Base Washer Rubber Faucet Base Washer Metal Washer Slotted Air Gap Slot Shape may vary Spacer Faucet Air Gap Washer Faucet Nut Fauc...

Page 14: ...d Tape 25 GPD Yellow Casing Black Tape 50 GPD Yellow Casing White Tape 75 GPD Yellow Casing Blue Tape Cartridge Carbon AES 10 micron O Ring Filter Housing Housing Filter Circuit Board Battery 9 volt E...

Page 15: ...et In 30 minutes check connections for leaks and correct if necessary Icemaker Extra point of use Check connections on these supply lines for leaks 10 Allow storage tank to fill overnight 11 WARNING D...

Page 16: ...e water Inspect them for damage i e nicks scratches Replace damaged O rings 8 CAUTION Do not get Smartap Water Quality Monitor electronics wiring or connectors wet Clean filter housings and manifold p...

Page 17: ...move battery by sliding it out of its holder 26 Slide new battery into its holder 27 CAUTION Verify battery connector alignment before making connection Figure 9 Connect battery by pressing clip onto...

Page 18: ...factory drain storage tank sanitize system and replace membrane Drain storage tank and let it refill overnight LEAKAGE AND NOISE Symptom Probable Cause Solution Leak at fitting Tubing not pushed compl...

Page 19: ...he drinking water system is altered by anyone other than WaterGroup the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICU...

Reviews: