16
PREMIER 2 SINGLE-SPEED INSTALLATION AND MAINTENANCE MANUAL
ECM2
Fan Motor
NOTE 9
P11
2
3
4
5
1
PB2
Auxiliary Electric Heat Power
208-230/60/3
Violet
Blu
With optional Premier ' EA' Series
Auxiliary ElectricHeat
Typical schematic shown
2
3
HE1
TS1
HE2
TS2
HE3
TS3
P7
L1
L2
Grn
Yel
Yel
Blk
Gray
Yel
Gray
Blk
Yel
Blk
Blk
Gray
F2
P9
ER1
ER2
ER3
ER4
L3
NO
NO
NO
NO
Or
Brn
Or
5
4
Pink
Orange
White
Tan
Blue
On/Off
PWM
RPM
C2
RPM grnd
P12
Violet
Blue
Yellow
Black
Gray
Red
Premier2
EA Series PCB
17P514A01
1
1
2
3
P10
4
5
6
P2
1
15
10
16
3
8
4
3
2
1
P8
1
2
3
4
G
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Switch -Hot Water On/Off
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
CR1 -
CR2-
CR3 -
CR4 -
F1 and F2 -
FP -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Freeze protection sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch
Legend
Relay Contacts-
N.O., N.C.
G
T
1
3
2
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER1 to ER4 - Aux heat stage relays
HWL -
Hot water limit sensor
Premier2 Logic Board (Single-Speed Configuration) Physical Layout
1 2 3
1
P4
On
Off
SW1
240V - L2
240V - L1
Fused L2
Fused L2
Fused L2
F1
F1
R
R
Microprocessor
Premier2 SeriesLogic Board
17P513A01
CR2- Loop
Pump
N.O.
240V - L2
240V - L1
C
C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
P5
Fused L2
Fused L1
CR1- DHW
Pump
N.O.
CC
CC-GND
CCLO
CCHI
1
2
3
P3
2
3
4
5
6
7
8
9
10
11
12
1
On
Off
SW2
2
3
4
5
6
7
8
1
On
Off
SW3
2
3
4
5
P1
1
2
3
4
5
6
7
8
2
3
4
5
P2
6
7
1
R
C Y1 Y2
G
O
W
L
Shut
Down
ACC
NO
ACC
NC
ACC
COM
C
C
SL1
IN
SL1
Out
SL2
IN
SL2
Out
Notes:
1 - Switch blue and red wires for 208V
operation.
2 - Connection of remote unit that does not
have a loop pump for slave operation.
3 - 24V Accessory relay (see SW2 - 3
for description of operation)
4 - The blk/wh and gray/wh wires are
removed when Aux Heat is installed
(ECM2 Only).
5 - DHW pump only in models with hot
water generation option.
6 - Air Flow Configuration Example: SW1
configured for dip 3 as low, dip 5 as
medium, and dip 7 as high speed
ECM2 fan.
7 - SW3-4 should be in the ON position
when using Premier 2 Electric Heat
control 17P514A01, and it should be in
the OFF position when using Premier
Electric Heat control 17P501A01.
8- When using thermostat TA32E12,
SW2 -8 should be in the "on" position.
When using 24VAC thermostats,
SW2-8 should be in the "off" position.
Brn
Gray
Gray
Blk
Gray
Blk
Yel
Yel
Grn