Literature Number 31973
hydro flame
™
Furnace Models
SERIES AFS
SERIES AFM
SERIES AFL
User’s Information Manual
1120 North Main Street • Elkhart, IN 46514
USA & Canada :
1-866-869-3118
Internet:
http://www.atwoodmobile.com
English, Français (ET Canada)
Should you require further information, contact your dealer or nearest
Atwood Mobile Products.
Follow this instruction to insure safe operation of the furnace.
This book contains instructions covering the operation and
maintenance of your furnace. Keep with unit at all times.
“FOR COMPLETE INSTALLATION INSTRUCTION REFER TO THE
INSTALLATION OWNER’S MANUAL”
FOR YOUR SAFETY READ ALL INFORMATION
BEFORE OPERATING FURNACE
SAFETY SYMBOLS
SAFETY ALERT SYMBOLS
Safety symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.
WARNING
Avoid possible injury or death
CAUTION
Avoid possible injury and/or
property damage
WARNING
Installation of this appliance must be made in accordance with
the written instructions provided in this manual. No agent,
representative or employee of Atwood or other person has the
authority to change, modify or waive any provision of the
instructions contained in this manual.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or
loss of life. Refer to the installation instructions and/or
owner’s
manual provided with this appliance.
WARNING
FIRE OR EXPLOSION
Be
sure the furnace and all ignition systems are “OFF” during
any type of refueling and while vehicle is in motion or being
towed.
EFFECTIVE 1/15
WARNING
FIRE OR EXPLOSION
If information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this appliance.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in dangerous
operation, serious injury, death or property damage.
Improper servicing could result in dangerous operation, serious
injury, and death or property damage.
Before servicing, disconnect all electrical power to furnace.
When serving controls, label all wire prior to disconnecting,
reconnect wires correctly.
Verify proper operation after servicing.
DO NOT store or use gasoline or other flammable vapors and/or
liquids in the vicinity of this or any other appliance.
DO NOT use the furnace cabinet area as a storage compartment.
DO NOT block furnace outlet registers or return air grills.
Keep all insulating material away from furnaces
CAUTION
PERSONAL INJURY
DO NOT touch exterior exhaust grills, when furnace is
operating.
Supervise young children in the same room as the
furnace.
WARNING
POSSIBLE INJURY OR DEATH
Do not operate furnace while vehicle or trailer is in motion.
WARNING
FIRE OR EXPLOSION
DO NOT refuel gasoline tanks or LP tanks unless the
gas has been turned OFF at the LP tank disabling all gas
appliances and pilot lights.
DO NOT over fill LP gas tanks.
LP tanks must be filled by a qualified gas supplier only.
Follow tank manufacture’s operating instructions located
on tank.
Liquid gas from an over filled tank can be forced through the
pressure regulator resulting in high pressure gas escaping,
causing fire/explosions.
LOCATION AND PHONE NUMBERS QUALIFIED SERVICE CENTERS
Website
http://www.atwoodmobile.com
Call 866-869-3118 for Atwood Service Center List
TO THE INSTALLER:
LEAVE THIS MANUAL WITH THE
APPLIANCE.
TO THE CONSUMER:
RETAIN THIS MANUAL FOR FUTURE
REFERENCE.