B.   When set for NAT and LP is required: 

Unscrew plug and replace plug with the correct plug into 
tower for LP. 
LP should now be visible. 
Finger tighten plug or with small wrench.  DON’T over 
tighten. 

4. 

This plug has been factory calibrated for this valve only.  DO NOT 
modify and DO NOT use plug on any other valve. 

5. 

Install the correct main burner orifice per the chart. 

 

ORIFICE REPLACEMENT 
 

1. 

Remove gas line from valve. 

2. 

Remove burner assembly by removing 3 screws from back wall of 
control box. 

3. 

Remove two screws holding the burner to the manifold. 

4. 

Unscrew the orifice with a 7/16” wrench or socket and replace 
with the correct orifice per the chart corresponding to type of gas 
required, which corresponds to the regulator plug setting. 

5. 

Replace two screws holding burner to manifold. 

6. 

Reinstall the burner assembly and put the three screws back into 
the control wall. 

7. 

Replace the gas line and check for leaks. 

8. 

After converting furnace, IN PLAIN SIGHT, put “converted” sticker 
(provided in you conversion packet) next to model number label. 
 

 

BURNER:

 Requires no adjustment, inspect annually. Burner 

should be cleaned with a wire brush to remove debris and 
corrosion build up. 

 

 

COMBUSTION CHAMBER:

 Check air intake and flue areas for 

internal obstructions (wasp or bird nests, etc.) To clean 
obstructions-remove the combustion chamber, flush with water 
and completely dry before replacing. Replace combustion 
chamber if any cracks or holes are found.  This condition is not 
field repairable. 

 

 

CONTROL COMPARTMENT:

 Remove dirt and lint. 

 

 

DUCTING:

 Must be cleaned and clear of obstructions. Reconnect 

any ducts that have become loose.

 

 

 

 

GAS PRESSURE TEST:

 Using a U-tube Water Monometer the 

entire piping system must be maintained within a range of 10-

14” 

W.C. when all appliances are in operation. Test the gas 
connections for leaks with a leak test solution. 

 

 

GAS SUPPLY SYSTEM:

 To test for gas leaks, perform a 

pressure drop test according to current ANSI standards. 

 

 

GASKETS:

 Inspect all gaskets for tight seals, DO NOT reuse 

gaskets 

– always replace with new. Worn seals my allow carbon 

monoxide to enter the living areas and cause illness or death. 

 

GENERAL:

 Physical support system must be sound, without 

sagging cracks gaps, etc. 
 

 

MOTOR:

 Requires no oiling. Permanently sealed and lubricated. 

 

 

RETURN AIR:

 Must be cleaned and clear of obstructions. 

 

 

VENTING:

 Exhaust tube and furnace chamber tube must overlap 

no less than 1-

1/4” and be positioned against the door for proper 

function. 
 

 

VOLTAGE:

 Low voltage can cause furnace to overheat and 

cycle. High voltage can cause unbalanced combustion and 
excessive motor wear. DC voltage should be maintained 11 to 
13.6 VDC at the furnace during operation for best performance. 
Check power with applicable power sources (generator, battery 
and converter). 

 

 

WIRE CONNECTIONS:

 Check for loose, disconnected or worn 

insulation areas.

 

 

WARRANTY 
 

Atwood Mobile Products 

hydro flame

™ FURNACE LIMITED WARRANTY 

Atwood  Mobile  Products  LLC  warrants  to  the  original  owner  and 
subject  to  the  below 

mentioned  conditions,  that  this  hydro  flame™ 

product will be free of defects in material or workmanship for a period 
of  two  years  from  the  original  date  of  purchase.  Atwood’s  liability 
hereunder  is  limited  to  the  replacement  of  the  product,  repair  of  the 
product, or replacement of the product with a reconditioned product at 
the discretion of the manufacturer. This warranty is void if the product 
has been damaged by accident, unreasonable use, neglect, tampering 
or  other  cause  not  arising from  defects in material  workmanship.  This 
warranty  extends  to  the  original  owner  of  the  product  only  and  is 
subject to the following conditions: 
 
1. 

For  two  years  from  the  date  of  purchase,  Atwood  will  repair  or 
replace  any  part  defective  in  material  or  workmanship.  This 
warranty  includes  reasonable  labor  charges  required  to  remove 
and replace the part. Service calls to customer’s location are not 
considered  part  of  these  charges  and  are,  therefore,  the 
responsibility of the owner. 

 
2. 

This  warranty  does  not  cover  the  following  items  classified  as 
normal maintenance: 

 

ADJUSTING 

–  gas  pressure,  voltage,  loose  wire 

connections, and/or thermostat heat anticipator. 

 

CLEANING 

– air wheels, burner and/or burner orifice 

 

CLEANING OR ADJUSTING

 

– heat chamber, heat ducting, 

return air opening, and/or exhaust tubes. 
 

3. 

In  the event  of  a  warranty  claim,  the owner  must  contact,  in 
advance,  either  an  authorized  Atwood  Service  Center  or  the 
Atwood Service Department. Warranty claim service must be 
performed at an authorized Atwood Service Center (a list will 
be  provided  at  no  charge)  or  approved  by  the  Consumer 
Service Department, 1120 North Main, Elkhart, IN 46514 USA. 
Phone: 

1-866-869-3118

 

4. 

RET

URN PARTS MUST BE SHIPPED TO ATWOOD “PREPAID”. 

Credit for shipping costs will be included with the warranty claim. 
The  defective  parts  become  the  property  of  Atwood  Mobile 
Products  LLC  and  must  be  returned  to  the 

Atwood  Mobile 

Products, 

Quality 

Assurance 

Dept., 

Salt 

Lake 

City 

Operations,  1874  South  Pioneer  Road,  Salt  Lake  City,  Utah 
84104, USA. 

 

5. 

This  warranty  applies  only  if the unit  is  installed  according  to  the 
installation instructions provided and complies with local and state 
codes. 

 
6. 

The warranty period on replacement parts is the unused portion of 
the original warranty period. 

 
7. 

Damage or failure resulting from misuse (including failure to seek 
proper repair service), misapplication, alterations, water damage, 
freezing, 

or  not  using  genuine  Atwood  parts  are  the  owner’s 

responsibility. 

 
8. 

Atwood  does  not  assume  responsibility  for  any  loss  of  use  of 
vehicle,  loss  of  time,  inconvenience,  expense  for  gasoline, 
telephone, travel, lodging, loss or damage to personal property or 
revenues. Some states do not allow the exclusion or limitation of 
incidental  or  consequential  damages,  so  the  above  limitations  or 
exclusions may not apply to you. 

 
9. 

Any  implied  warranties  are  limited  to  (2)  two  years.  Some  states 
do not allow limitations on how long an implied warranty lasts, so 
the above limitation may not apply to you. This warranty gives you 
specific  legal  rights  and  you  may  also  have  other  rights  which 
vary from state to state. 

 
10.  Replacement  parts  purchased  outside  of  the  original  furnace 

warranty  carry  a  90  day  warranty.  This  includes  the  part  at  no 
charge and reasonable labor charges to replace it. 

 
This hydro flame furnace is designed for use in recreation vehicles for 