 WARNING 

If  you  do  not  follow  these  instructions  exactly,  a  fire  or 
explosion may result causing property damage, personal injury 
or loss of life. 

 

 WARNING 

FIRE OR EXPLOSION 

 

Improper installation, adjustment, alteration, service or 
maintenance can cause property damage, personal 
injury or loss of life. Refer to the installation instructions 
and/or owner’s manual provided with this appliance. 

 

Installations, repairs and preventive maintenance should 
be done by a qualified Service Technician only. 

 

  

WARNING 

POSSIBLE INJURY OR DEATH 

If  the  user  of  this  appliance  fails  to  maintain  it  in  the  condition  in 
which it  was shipped from the factory or if the appliance is not  used 
solely  for  its  intended  purpose  or  if  appliance  is  not  maintained  in 
accordance with the instructions in this manual, then the risk of a fire 
and/or  the  production  of  carbon  monoxide  exists  which  can  cause 
personal injury, property damage or loss of life. 

 

  

WARNING 

CARBON MONOXIDE POISONING 

 

Doors  must  be  properly  sealed  and  draft  cap  and  assemblies 
must  be  adjusted  and  sealed  correctly  to  prevent  carbon 
monoxide from entering coach. 

 

Combustion air must NOT be drawn from within any living area. 

 

DO NOT vent exhaust into living area or outside into an enclosed 
porch area. 

 

DO  NOT  vent  any  other  appliance  with  venting  systems  serving 
the furnace. 

 

DO  NOT  allow  snow  or  any  objects  to  block  exhaust  system  of 
furnace. 

 

  

WARNING 

POSSIBLE INJURY OR DEATH 

Do  not  install  screens  over  the  intake  air  or  exhaust  vents  for  any 
reason.  Screens  will  become  restricted  and  cause  unsafe  furnace 
operation.  Accessories  are  being  marketed  for  RV  products  which  we 
do not recommend. For your safety, only factory authorized parts are to 
be used on your furnace. 

 

  

WARNING 

POSSIBLE INJURY OR DEATH 

Do  not  use  this  appliance  if  any  part  has  been  under  water.  A  flood-
damaged furnace is extremely dangerous. Attempts to use the furnace 
can result in fire or explosion.  
A qualified service agency should be contacted to inspect the furnace 
and  to  replace  all  gas  controls,  control  system  parts,  electrical  parts 
that have been wet or the furnace if deemed necessary.

 

 

Listed  below  are  several  safety  related  items  that  you  the  (owner) 
should follow each heating season to assure continued safe operation 
of  the  furnace.  A  periodic  inspection  of  the  furnace  by  a  qualified 
service agent is also recommended. 
 

 

Inspect furnace venting. Venting must be free of obstructions, 
void of soot and properly terminated to the atmosphere. Make 
sure that the vent assembly is positioned tight against outer door. 

 

Periodically inspect the vent for obstructions or presence of soot. 
Soot is formed whenever combustion is incomplete. This is your 
visual warning that the furnace is operating in an unsafe manner. 
If soot is present, immediately shut furnace down and contact 
your dealer or a qualified service person. 

 

Keep furnace clean. More frequent cleaning may be required due 
to excessive lint from carpeting, bedding material, pet hair etc. It 
is imperative that control compartments, burners, and circulating 
air passageways of the appliance be kept clean and 
unobstructed. 

 

The motor is permanently lubricated and requires no oiling. 

 

Keep the furnace area clear of any combustible materials, 
gasoline, or other flammable vapor and liquids. 

 

Before operating furnace, check the location of the furnace vent to 
make sure it will not be blocked by the opening of any door on the 
trailer. If it can be blocked, do not operate the furnace with the 
door open. 

 

Do not restrict the flow of combustion air or the warm air 
circulation to the furnace. To do so could cause personal injury 
and/or death. 

 

Never operate the furnace if you smell gas. Do not assume that 
the smell of gas in your RV is normal. Any time you detect the 
odor of gas, it is to be considered life threatening and corrected 
immediately. Extinguish any open flames including cigarettes and 
evacuate all persons from the vehicle. Shut off gas supply at LP 
gas bottle. (See safety notice in this manual). 

 

Immediately shut furnace down and call a service agency if 
furnace cycles erratically or delays on ignition. 

 

Never attempt to repair the furnace yourself. Seek the help of a 
qualified service person. 

 

Never restrict the ducting installed by your trailer manufacturer. 
To do so could cause improper furnace operation. 

 

Do not install air boosters in the duct system. Such devices will 
cause the furnace to cycle on limit and to have erratic sail switch 
operation. 

 

Clothing or other flammable material should not be placed on or 
near the appliance. 

 

Always follow the Operating Instructions. Do not deviate from the 
step-by-step procedures. 

 

When considering add-on rooms, porch or patio, attention must 
be given to the venting of our furnace. For your safety, do not 
terminate furnace vent inside add-on rooms, screen porch or onto 
patios. Doing so will result in products of combustion being vented 
into the room or occupied areas. 

  In any installation in which the vent of the appliance can be covered 

due to the construction of the RV or some special feature of the RV 
such as slide out, pop-up etc. Always insure that the appliance 
cannot be operated by setting the thermostat to the po

sitive “OFF” 

position and shutting off all electrical and gas supply to the 
appliance. Never operate furnace with vent covered. 

   DO NOT use petroleum or citrus type cleaner on plastic parts, as 

damage may occur. 

 
 

 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 