ELECTRICAL CONNECTION
Note:
When carrying out any work on this
appliance, the electrical supply to it must be
isolated.
The appliance requires a 230 volt, 50Hz A.C. sup-
ply and the electrical installation must be carried
out by a qualified electrician in compliance with the
current regulations. The appliance must be con-
nected to a cooker box control unit with a sufficient
amperage rating with maximum possible load (as
specified in the Maximum Electrical Power Table)
using an adequately sized cooker cable. The
power lead must not reach a temperature in excess
of 50
o
C.
MAXIMUM ELECTRICAL POWER USAGE
COOKER MODEL
Waterford 60cm Dual Fuel
2295
10.0
Waterford 60cm Electric
8995
39.1
Waterford 70cm Dual Fuel
2295
10.0
Waterford 90cm Dual Fuel Double Oven
3564
15.5
Waterford 90cm Electric Double Oven
12486
54.3
Waterford 100cm Dual Fuel Double Oven
3564
15.5
Waterford 120cm Dual Fuel Double Oven
4545
19.8
W
A
The power cable supplied with the cooker can be
removed. Accessing the terminal block (See Fig
4), to disconnect the power cable, by removing the
back panel (i.e. remove the four self tapping
screws on each side of the panel). When connect-
ing the new cable, ensure that it is connected to
correct terminals and fixed with the cable clamp.
Fig.4
VENTILATION
The room where the gas appliance is installed
must be well ventilated to allow proper gas com-
bustion and correct ventilation during operation of
the appliance. The air flow necessary for proper
combustion must be no less than 2m
3
/h for each
kW of the appliance’s maximum rated power. The
maximum rated power and corresponding air flow
requirement are detailed in the table below.
When fitting an extraction hood over the appliance,
ensure that there is a permanent air vent to the
room that allows adequate ventilation for both the
hood and cooker.
Product
Max Power Rating
(kW)
Min Air Flow
Requirement
(m
3
/h)
60cm Dual Fuel
8.1
16.2
70cm Dual Fuel
11.1
22.2
90cm Dual Fuel
11.1
22.2
100cm Dual Fuel
11.1
22.2
120cm Dual Fuel
16.2
32.4
NOTE:
ALL DUAL FUEL MODELS ARE CONFIGURED FOR NATURAL GAS AS STANDARD. IT IS THE
INSTALLER’S RESPONSIBILITY TO MAKE THE NECESSARY MODIFICATIONS (AS OUTLINED IN THE SECTION
ON CONVERTING FOR LPG) TO ENSURE THE APPLIANCE IS CORRECTLY CONFIGURED FOR USE ON LPG.
GAS CONNECTION - NATURAL GAS
This appliance should be connected using a
O12mm metal hose that complies with the National
Regulations with the connection made to the gas
connection pipe either on the left or right side of the
appliance (See Fig. 5) using an appropriate seal
between the pipe and hose. The hose must never
be more than 1.5 meters long and should not pass
behind the appliance.
Fig.5
11
ADDITIONAL INSTALLATION INSTRUCTIONS FOR DUAL FUEL APPLIANCES