background image

18

 

Booster Pump Starting and Stopping Frequently Reminder

The front panel screen shows code E04, buzzer sounds 5 times.
There is an internal pressure imbalance. Disconnect the power. Turn on or turn off RO faucet 
completely, remove all tubing crimps. Make sure the faucet is not blocked and power on 
the system again. 

 

  Loud Sound of RO System

The sound will not exceed 65 DB, which makes no difference to everyday lives (65 DB is 
tested under standard laboratory conditions, feed water pressure is between 14.5 PSI and 87 
PSI). Loud sound may be caused by following reasons: 

a.  The system is not positioned in a flat area. Make sure the system is placed smoothly 

without shaking.

b.  The system is placed against the cabinet. Do not place the system against the cabinet. 

The system may vibrate when it works. 

c.  The water pressure is instable. Check and confirm the water pressure is between 14.5 PSI 

and 87 PSI. The sound will decrease when water pressure becomes stable. 

 

Water Shortage Reminder

The front panel screen shows code E01, buzzer sounds 3 times. 

a.  Check if it is out of water, turn on feed water adapter or water supply valve.
b.  The inlet water tubing is crimped. Check and remove crimps.

 

Booster Pump Overworked Reminder.

The front panel screen shows code E03, buzzer keeps beeping for 3 minutes.

a.  Continuously dispensing water for more than 30 minutes. Power on the system again to 

recover.

b.  There is a leak at the tubing connection between the system and RO faucet. Turn off 

the power. Check the tubing connection, make sure tubing is inserted into the quick-
connect fitting properly and firmly, and power on the system again. 

 

 TDS Reading Fluctuates When Dispensing Water

a.  The TDS reading displayed is the TDS of flowing filtered water. Therefore, the content of 

dissolved solids may vary slightly as water flows, causing the fluctuation of TDS reading.

b.  The built-in TDS sensor has deviation, causing the fluctuation of TDS reading.

 

 The Difference between the TDS Reading Tested by TDS Meter and the 
Displayed Reading

a.  The reading tested by TDS Meter is the TDS of static water in the container while the TDS 

reading displayed by the system is the TDS of flowing water. As a result, the TDS readings 
are different. 

b.  There are errors in TDS Meter tests.

 

Filtered Water from RO Faucet Tastes Like Tap Water

a.  Incorrect tubing installation. Make sure the waste water tubing is not connected with RO 

faucet.

b.  The filters are not well installed. Check and make sure the filters are placed in properly.
c.  Filter expires. Check the filter life indicators to confirm which filter needs to be replaced 

and replace immediately. 

Summary of Contents for WD-G3-B

Page 1: ......

Page 2: ......

Page 3: ...conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any Changes or modificatio...

Page 4: ......

Page 5: ...ition the RO System Housing 7 Step 5 Connect Tubing 8 Step 6 Connect Power Cord 9 Step 7 Install the Filters 9 Step 8 Start Up the System 10 Other Outputs Connection Optional 11 OWNER S MANUAL Display...

Page 6: ...ick installation Specifications To achieve the optimal performance it is highly recommended to use the system within the operational parameters Model RO System Size L W H Feed Water Pressure Feed Wate...

Page 7: ...Drain Saddle 1 4 Teflon Tape Red 1 4 PE Tubing White 3 8 PE Tubing Lock Clip X 1 Set X 1 Set X 1 Set X 1 Set X 1 X 1 Set X 60 X 60 X 60 X 5 Pre sediment and Carbon Block Filter CF WD G3 N1CF X 1 Rever...

Page 8: ...r Port M J From Drain Saddle to WASTE Water Port O G FromFaucetPowerCordto FAUCET Connector F N From POWER Port to Power Socket H INPUT Water Port I FILTERED Water Port J WASTE Water Port Filtered Wat...

Page 9: ...fitting It will lock the tubing in place and prevent it from falling off To disconnect Remove the blue lock clip from the fitting Use your thumb and index finger to press down the lock sleeve Use you...

Page 10: ...n Your Sink or Countertop Optional NOTE Please confirm if there is an existing hole available to install the RO faucet If not please drill a hole in accordance with the following steps It s highly rec...

Page 11: ...d into the hole on countertop 3 Under the sink put the mounting washer on faucet stem slip on the nut and tighten it up 4 Insert the quick connect fitting onto the faucet stem fully and firmly Faucet...

Page 12: ...re is sufficient space under the countertop to install the system 18 06 5 68 17 76 Position the front panel facing towards you which will be convenient for future filter replacement and indicator chec...

Page 13: ...all the FILTERED Water Tubing Remove the plug from FILTERED water port Identify the white 1 4 PE tubing Insert one end of the PE tubing into the quick connect fitting on RO faucet Figure 13 and pop in...

Page 14: ...Figure 18 Drain Saddle WASTE Water Tubing WASTE Water Port Lock Clip WASTE Water Tubing Figure 15 Figure 16 Step 6 Connect Power Cord Connect RO faucet with the system Insert the power cord which is...

Page 15: ...ucet is turned on and water is not drinkable during the automatic flush 4 Turn on RO faucet allow it to run 30 minutes until the front panel screen starts displaying TDS reading Figure 23 NOTE Be sure...

Page 16: ...eeds a bypass Any questions please contact us by Phone 1 888 352 3558 Mon Fri 8 00 AM 5 00 PM PST or by Email service water filter com NOTE If you missed the free accessory kit when purchasing RO clai...

Page 17: ...ed the system Register your product now for 1 YEAR MANUFACTURER WARRANTY Please refer to Limited Product Warranty on Page 19 Visit www water filter com warranty Scan the QR code or Text WDRO to 31996...

Page 18: ...water usage The TDS reading may vary as the water is flowing The TDS display will go o after 5 minutes when the system stops making water Section 2 Filter Life Reminder Figure 25 TDS Reading Pre sedim...

Page 19: ...utes when the system stops making water Check the filter life status by touching the indicators and the lights will go off in 30 seconds 1 Filter Life Indicator on System Housing There are helpful ele...

Page 20: ...re 29 protruding at the top of the old filter to release pressure to avoid water spills Get a towel or bucket to catch any water drips 2 Twist the new filter into the housing in clockwise direction 3...

Page 21: ...inute when there is no water dispensing for 24 hours front panel screen displays as Figure 30 If the user takes water during flushing the system will quit flushing and switch to dispensing Flush for P...

Page 22: ...not spray the water directly Do not use steel wool abrasive cleaner or corrosive liquid such as gasoline or acetone When cleaning do not pour other liquid into the filter to avoid damage to the filte...

Page 23: ...0 TDS rejection rate tested under standard laboratory conditions when working properly If the TDS reading is high the following are the possible causes a The system hasn t been used for a long time Op...

Page 24: ...d Reminder The front panel screen shows code E03 buzzer keeps beeping for 3 minutes a Continuously dispensing water for more than 30 minutes Power on the system again to recover b There is a leak at t...

Page 25: ...y seasonably or over a period of time Your water usage may vary as well The manufacturer assumes no liability for the determination of the proper equipment necessary to meet your requirements and we d...

Page 26: ...oducts Please be sure to fill in the order information upon registration of your system For any questions and concerns about the product please feel free to call or email us Your satisfaction is our t...

Page 27: ......

Page 28: ......

Reviews: