Step 8:
Start Up the System
1. Turn on cold water supply valve . Check for leaks;
2. Insert the plug of power adapter into socket;
3. The system starts flushing automatically for 5 minutes;
NOTE:
There is one beep sound. Filter life indicators flash blue, yellow and red light in
turn and then turn blue for 5 minutes (Figure 22). Do not turn on RO faucet, allow the
system to flush automatically for 5 minutes. The three indicator lights will be off when
the flush is completed.
NOTE:
A slow water flow is normal if the RO faucet is turned on, and water is not
drinkable during the automatic flush.
4. Turn on RO faucet, allow it to run 30 minutes until the front panel screen starts
displaying TDS reading (Figure 23);
NOTE:
Be sure to carefully check the tightness of each part of the system while flushing.
Check and ensure all tubings are installed correctly and completely. Make sure there is
no leaking at joints, fittings, valves and tubing connections
.
NOTE:
The water is not drinkable during the flushing. The 30 minutes are accumulative.
If the flush is stopped in advance, the system will continue to flush when you open RO
faucet again until it reaches 30 minutes.
5. Confirm the flush is completed before turning off the RO faucet and ensure it’s not
leaking.
Figure 22
Figure 23
TDS Reading
Flushing
Status