background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pool Heat Pump

 

| Pg 30

 

 

WARRANTY 

 

Waterco does not guarantee and will not pay for

1. 

Service calls to: 

-

 

Inspect and/or correct the installation of your pool heat pump. 

-

 

Instruct you on how to use your pool heat pump. 

-

 

Replace house fuses or correct power supply problem. 

-

 

Adjust or re-establish water flow to the pool heat pump. 

2. 

When a service call with no manufacturing problem has been detected, on site, by the 
service company mandated by Waterco. 

3. 

Damage to your pool heat pump caused by accident, misuse, fire, flood, storms, natural 
disasters,  improper  installation,  harsh  environment,  chemical  feeding  before  the  pool 
heat  pump,  improper  maintenance  of  water  chemistry  or  any  problem  related  with 
instructions  described  in  the  Use  and  Care  Guide  and  not  followed  by  the 
purchaser/end-user. 

 

4. 

Damage  to  internal  piping  or  components  due  to  improper  winterizing  before  freezing 
conditions. 

5. 

Repairs  to  parts  or  system  resulting  from  unauthorized  modification  made  to  the  pool 
heat pump. 

6. 

Repairs not previously authorized by Waterco. 

7. 

Parts and pool heat pump transportation. 

8. 

Fees charged for excessive time to repair your pool heat pump due to incorrect or un-
accessible  location.    This  may  void  warranty  cover  and  the  owner  will  be  required  to 
pay a service call fee even if the unit is not repaired.   

 

 

Waterco’s obligation to repair or replace at Waterco’s option, shall be the original purchaser’s 
sole  and  exclusive  remedy  under  this  warranty.  Waterco  shall  not  be  liable  for  incidental, 
consequential  or  special  damages  arising  out  of  or  in  connection  with  product  use  or 
performance.   

Waterco  is  not  responsible  for  direct  or  indirect  damages  resulting  from  defective 
components. This warranty gives you specific legal rights and you may also have other rights, 
which vary from state or province to another. 

WARRANTY 

     

      

IMPORTANT

 

Before you contact Waterco for assistance or service, please check the 

“Troubleshooting”

 

and the information stated in this section.  Warranty will only cover manufacturing defects.All 
service  call  requests  which  are  not  of  this  nature  must  be  paid  by  the  purchaser  to  the 
service company authorized by Waterco. 

Warranty service is to be completed by an authorized Service Center authorized by Waterco. 
Where applicable, in home service will be made available only in areas where a contracted 
service provider offers service.  
 

If in home service is not available, the product will be repaired or replaced at Waterco 
discretion  by  the  nearest  authorized  service  provider.  The  unit  removal  and 
reinstallation  works  are  under  the  customer  responsibility,  and  Waterco  cannot  be 
charged for them. 

 

** DO NOT return the unit to your dealer as they do not provide the service work. ** 

When you contact Waterco for assistance or service, in order to qualify for a warranty claim, 
the original purchaser must have the model name and serial number along with a proof of the 
original  purchase  date.   

Proof  of  purchase must  be forwarded  to Waterco  and  they  will 

inform you of the applicable warranty

.  

Once  connected  with  a  Waterco  customer  service  agent,  proceed  to  describe  in  detail  the 
problem associated with your pool heat pump.  If a permanent code appears on the electronic 
control panel, please advise the Waterco service agent. 

Waterco

 

guarantees to the 

original purchaser

 of the pool heat pump that the product is free 

from any manufacturing defect (raw materials and labour).   

IMPORTANT

:  The  warranty  is  not  transferable  and  no  action  can  be  exercised  by  a 

consumer, subsequent purchaser, of the pool heat pump. 

When buying the pool heat pump, Waterco guarantees parts and labour for a specific 
determined period to correct defects in materials or workmanship.  Contact Waterco to 
find out the warranty that is applicable for your model. 

There  is  no  other  warranties,  express  or  implied,  including,  but  not  limited  to,  implied 
warranties  of  merchantability  or  fitness  for  a  particular  purpose.  During  warranty  period, 
Waterco  will,  at  its  option,  repair  or  replace,  without  charge,  any  product  or  part,  which  is 
found to be defective under normal use and service. 

 

 

Summary of Contents for POOL HEAT PUMP

Page 1: ...t Une installation inadéquate annulera la garantie Notice to Installer Avis à l installateur This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment Ce manuel contient des informations importantes sur l installation l exploitation et l utilisation s...

Page 2: ...___ Compressor Starts and Stops ____________ There Is Water Around the Pool Heat Pump _ Pool Heat Pump Has Ice Formed On the Evaporator Coil _________________ Pool Heat Pump Is Not Heating ___________ Analysis Chart ________________________ Circuit Breaker Trips ___________________ Pool Heat Pump Is Noisy ________________ The Temperature Shown on Pool Heat Pump Is Not the Same than the Pool Thermo...

Page 3: ...ded for proper operation and heating Please refer to the section Location on the following page IMPORTANT Usage of Chemical Products Never add liquid chlorine granular chlorine or slow dissolving tablets pucks into the skimmer basket This high concentration of chemicals should be avoided Water quality standards that must be strictly adhered to Warranty can be voided if not maintained within these ...

Page 4: ...ir is pulled through the evaporator coil and discharged through the top or front grill Clearances should be allowed in front and around the unit for unrestricted air discharge and service access See Figure 1 and Figure 2 Re circulation of cold discharged air back into the evaporator coil will greatly reduce the unit s heating capacity and efficiency Pool Heat Pump Pg 06 No obstruction above Pool H...

Page 5: ... MUST be installed between the pool heat pump and any automatic chlorinator to prevent highly chlorine concentrated water from flowing back to the pool heat pump when the pool pump is not running 2 Units that are located below the water level of the swimming pool may require the pressure switch to be adjusted This can be checked by the following method Switch ON the water pump and the pool heat pu...

Page 6: ... these systems may leak stray voltage and currents into the water causing severe electrolysis This dramatically shortens the life of the pool heat pump and will void the warranty NOTE Bonding to pool pump is not required for above ground pool pumps but all other equipment must be bonded Pool water temperature must be above Atmospheric conditions must be above Model Ultra Reversible XLR All others ...

Page 7: ...g back to the pool water temperature when all keys remain untouched for 5 seconds To change the temperature display from Fahrenheit F to Celsius C press the button C F The led below the F or C will be lit to indicate the current selection Note The pool heat pump will stop working when the programmed temperature is reached OPERATION OF YOUR POOL HEAT PUMP Pool Solar Blanket A pool solar blanket sho...

Page 8: ...e XLR Electronic Control with Diagnostics Functioning of your Electronic Control with Diagnostics and Reversible XLR Electronic Control with Diagnostics OPERATION OF YOUR POOL HEAT PUMP Temperature Calibration It is possible to have a temperature variation between the water in the swimming pool and the reading of the pool heat pump temperature probe sensor Example the water in the pool is 26 ºC 80...

Page 9: ... 70 F 21 C please adjust the bypass valve as shown Approx 60 of the water is circulating in the unit When the pool water temperature is between 70 F 21 C and 78 F 26 C please adjust the bypass valve as shown Approx 80 of the water is circulating in the unit When the pool water temperature is above 79 F 26 C please close the bypass valve as shown 100 of the water is circulating in the unit IMPORTAN...

Page 10: ...the pool heat pump s heat exchanger in preparation for winter 4 Once the piping is disconnected the pool heat pump s heat exchanger MUST be emptied the use of a water vacuum cleaner is strongly recommended or if you do not have this tool you can tilt the unit 75 until all the water is out 5 It is recommended that the pool heat pump s heat exchanger is rinsed out with a gentle water spray at the in...

Page 11: ...was condensation which is normal TROUBLESHOOTING Nothing Is Working but the Electronic Control Displays Digits or a Code 1 Identify the analyser code that the electronic control displays and refer to the section Service Analyser Codes 2 If the electronic control displays digits make sure that the electronic control is programmed correctly refer to the section Operation of your Pool Heat Pump and r...

Page 12: ...s free of debris and leaves 3 If the evaporator is dusty or dirty clean it with a light spray of water and allow it to dry do not use high pressure it may damage the evaporator fins 4 When the unit is dry you may switch it back ON from the circuit breaker 5 Ensure that the clearances around the unit are respected 6 When the unit has been switched ON ensure the fan motor is working fan blades will ...

Page 13: ...s coming from the pool heat pump and not from other equipment which will not be covered by the warranty e g noise coming from the bypass valve pool pump etc 3 An improper installation may cause this situation it will need to be corrected by the owner This situation is not covered by the warranty The Temperature Shown on the Pool Heat Pump Is Not the Same than the Pool Thermometer It is possible to...

Page 14: ...ure the pool pump is switched ON Press ON OFF to restart the pool heat pump On new installations ensure the installation instructions were respected Check that the pool water level is correct that the pool pump is filled with water to the rim and that water is flowing correctly through the pool pump to the pool heat pump Check swimming pool and pool pump skimmer baskets and the drain at the bottom...

Page 15: ...ics and reversible XLR electronic control with diagnostics Problem Action Remedy Problem Low refrigerant level in the pool heat pump or the low pressure safety control is defective Atmospheric conditions as well as the pool water temperature should not be below the minimum operating temperatures as stated below in order to obtain efficiency and avoid codes from appearing on the electronic control ...

Page 16: ...tion stated in this section Warranty will only cover manufacturing defects All service call requests which are not of this nature must be paid by the purchaser to the service company authorized by Waterco Warranty service is to be completed by an authorized Service Center authorized by Waterco Where applicable in home service will be made available only in areas where a contracted service provider...

Page 17: ...Piscine ___________ Cycle de Dégivrage ________________ Fonctionnement de votre Contrôle Électronique avec Diagnostiques et Contrôle Électronique avec Diagnostiques Réversible XLR _____ Pour Démarrer la Thermopompe Chauffe Piscine ____________________ Pour Arrêter la Thermopompe Chauffe Piscine ____________________ Pour Valider et Programmer la Température Désirée ________________ Pour Changer l A...

Page 18: ... produits d entretien tels le chlore liquide en granules ou les tablettes de chlore à dissolution lentes directement dans l écumoire de votre piscine afin d éviter une forte concentration de chlore qui se retrouverait dans l échangeur de chaleur de votre thermopompe chauffe piscine Les standards de la qualité de l eau à respecter ___________________________________________________ ________________...

Page 19: ...air est tiré au travers du serpentin de l évaporateur et rejeté par le dessus ou le côté de la thermopompe chauffe piscine selon le modèle Un espace libre doit être disponible autour et devant l unité pour ne pas restreindre le rejet de l air et l accès pour le service Voir figures 1 et 2 ci dessous La reprise de l air froid expulsée par l unité réduit grandement la capacité de chauffage et l effi...

Page 20: ... adéquat de votre thermopompe chauffe piscine tous les travaux électriques doivent être effectués par un électricien qualifié et ayant une licence selon les codes électriques locaux Un disjoncteur de calibre adéquat ainsi que du câble de cuivre doivent être utilisés Consultez la plaque signalétique de votre thermopompe chauffe piscine Il peut être nécessaire d installer un disjoncteur différentiel...

Page 21: ...essus de Température de l eau doit être au dessus de Ultra Modèle réversible XLR Tous les autres modèles Modèle 50 F 10 C 65 F 18 C 65 F 18 C 32 F 0 C 43 F 6 C 52 F 11 C La vitesse du réchauffement de l eau varie selon cinq facteurs 1 La dimension de la piscine 2 L élévation de température demandée 3 La température de l air ambiant 4 L utilisation d une toile solaire 5 La puissance de la thermopom...

Page 22: ...chauffe piscine et le moteur de ventilation se mettra en marche les hélices tourneront mais le compresseur ne démarrera pas L afficheur clignotera jusqu à ce que le compresseur démarre et lorsque la minuterie terminera son cycle de 3 à 5 minutes Après 5 minutes le compresseur démarrera et la température sur l afficheur cessera de clignoter Vous pourrez programmer la température désirée pour l eau ...

Page 23: ...mme un problème Fonctionnement Spécifique de votre Contrôle Électronique avec Diagnostiques Réversible XLR Durant le cycle de dégivrage le moteur de ventilation cesse de fonctionner et le gaz chaud est injecté dans l évaporateur afin de faire fondre le givre Cependant lorsque la thermopompe chauffe piscine effectue 4 cycles chauffage et dégivrage consécutifs en 1 heure l unité se place en mode pro...

Page 24: ... nos recommandations Lorsque vous utilisé une minuterie sur l un de nos appareils l unité arrêtera sous une protection d interruption de début le code nFL sera affiché jusqu au redémarrage de votre pompe de piscine IMPORANT Si vous désirez utiliser cette option prenez note que l unité pourra réchauffer votre eau de piscine seulement lorsque la minuterie permettre à votre pompe de fonctionner Exemp...

Page 25: ...nt et éviter qu un code d analyse s affiche sur le contrôle électronique ce qui habituellement ne représente pas un problème et n est pas couvert par la garantie Advenant le contraire l unité devra être arrêtée jusqu à l obtention des températures minimales de fonctionnement citées ci dessous Dans le cas des modèles Ultra et Réversible XLR l unité arrêtera de fonctionner sans intervention de votre...

Page 26: ...e 5 Si le problème persiste veuillez communiquer avec Waterco Thermopompe Chauffe Piscine Pg 58 DÉPANNAGE Eau Autour de la Thermopompe Chauffe Piscine La thermopompe chauffe piscine produira de la condensation de 1 à 1 5 gallons ou de 4 à 6 litres à l heure L eau s écoulera de la base de l appareil Pour empêcher l accumulation d eau vous pouvez utiliser de la pierre décorative autour de la dalle d...

Page 27: ...és qui pourraient obstruer l entrée d air et diminuer la performance de chauffage Laissez sécher votre évaporateur afin d éviter la formation de givre ou glace prématurée 4 Waterco recommande d utiliser une toile solaire pour conserver la chaleur de votre eau de piscine Une piscine non recouverte perd 2 à 3 fois plus de chaleur qu une piscine recouverte 5 Assurez vous que vous avez programmé adéqu...

Page 28: ...t de la piscine par exemple valve de retenu ou pompe 3 Une installation inadéquate pourrait causer cette situation en permanence et l installation devra être corrigée Cette situation n est pas couverte par la garantie Le Degré qu Affiche le Contrôle Électronique avec Diagnostiques et Réversible N est Pas le Même que celui du Thermomètre de la Piscine Il est possible qu il y ait une variation entre...

Page 29: ...e circulation d eau à la thermopompe chauffe piscine ou l interrupteur du contrôle de la pression d eau doit être ajusté ou est défectueux Que faire Si votre pompe de filtration est branchée à la thermopompe chauffe piscine assurez vous d avoir programmé votre contrôle électronique correctement vous référer à la section Comment programmer la minuterie du contrôle électronique Multi Fonction afin d...

Page 30: ... vous que le robot aspirateur soit déconnecté afin de ne pas réduire le débit d eau Si votre pompe à deux vitesses assurez vous que celle ci fonctionne à la vitesse la plus élevées Signification La sonde de température d eau est en cause branchement à vérifier ou sonde à changer Que faire Veuillez communiquer avec le service à la clientèle Condition atmosphérique doit être au dessus de 32 F 0 C 43...

Page 31: ...scine Cette garantie remplace toutes les autres garanties expresses ou implicites incluant les garanties relatives à la qualité marchande et à l usage Durant la période de garantie Waterco à sa discrétion réparera ou remplacera gratuitement toute pièce ou tout produit jugé défectueux et ayant été utilisé et entretenu de façon normale IMPORTANT Thermopompe Chauffe Piscine Pg 68 GARANTIE IMPORTANT W...

Reviews: