WATERCO OPAL CARTRIDGE FILTERS
The Waterco Opal Cartridge Filters do not require a media such as sand or D.E powder to operate, instead the
filter contains a cartridge element which is easily removed to clean or replace.
All Opal Cartridge Filters are ideal for use in swimming pool and spas.The Opal Cartridge Filters is also ideal for
use when backwashing is impractical.
INSTALLATION
Remove the cartridge filter from the carton and install the pressure gauge into the threaded port on the filter lid
provided. Using Teflon, wrap once around the brass pressure gauge thread in a clockwise direction and screw
into the threaded lid port.
Place the Opal Cartridge Filter into the required position. Ensure that it is on a flat level surface and is aligned
with the pump.
The Opal Cartridge Filter has marked inlet and outlet ports.
Ensure that the pipe extending from the pump outlet is connected to the Opal Cartridge Filter marked inlet.
Screw the supplied half barrel unions and tails onto the inlet and outlet before gluing the UPVC piping onto the
filter.
Cut and fit the pipe and fittings onto the Opal Cartridge Filter and the pump.
REFER
to Pump Installation Manual
for correct pump plumbing procedures.
It is
best practice
to fit all the cut pipe and fittings onto the filtration system
before
gluing; this will ensure that
the system has
been aligned
correctly.
Glue the pipe and fittings onto the pump, filter and pool return lines and
allow
the glue to set
for 24 hours
before
commissioning the system.
It is
advisable
to bolt the filter down to the floor where the filter is located. This will prevent the filtration plumbing
from
working with dyna bolts loose
with the expansion and operation of the filter during regular cycles. It will
also help to prevent unecessary stress on the plumbing while unscrewing the filter lid lock ring.
Hand tighten the pressure gauge into the lid only for sealing.
!
CAUTION
Use only the recommended glue for the connection pipes and fittings.
!
CAUTION