background image

Waterco Limited ABN 62 002 070 733

(W99302 / ZZM1449) 07/2013

Offices - AustrAliA

NSW - SydNey 
(Head Office)
Tel: +61 2 9898 8600

QLd - BriSBaNe
Tel: +61 7 3299 9900

Vic/TaS - MeLBOurNe
Tel: +61 3 9764 1211

Wa - PerTH
Tel: +61 8 9273 1900

Sa/NT - adeLaide
Tel: +61 8 8244 6000

acT diSTriBuTiON
Tel: +61 2 6280 6476

Offices - OVerseAs

WaTercO (eurOPe) LiMiTed
Sittingbourne, Kent, uK
Tel: +44 (0) 1795 521 733

WaTercO fraNce
Saint Priest, france
Tel: +33 4 72 79 33 30

WaTercO (uSa) iNc
augusta, Georgia, uSa
Tel: +1 706 793 7291

WaTercO caNada
Longueuil, Quebec, canada
Tel: +1 450 748 1421

WaTercO (NZ) LiMiTed
auckland, New Zealand
Tel: +64 9 525 7570

WaTercO © LiMiTed
Guangzhou, china
Tel: +86 20 3222 2180

WaTercO (far eaST) SdN BHd
Selangor, Malaysia
Tel: +60 3 6145 6000

PT WaTercO iNdONeSia
Jakarta, indonesia
Tel: +62 21 4585 1481

WaTercO SiNGaPOre iNTL PTe LTd
Nehsons Building, Singapore
Tel: +65 6344 2378

Summary of Contents for MultiCyclone 70XL

Page 1: ...the product has been installed this manual must be given to the owner operator of this equipment This equipment must be installed and serviced by a qualified technician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty WARNING 70XL Manual ...

Page 2: ...l replacement parts and accessories authorized by the manufacturer ensure a high level of safety Waterco assumes no liability for the damage and injuries caused by unauthorised replacement parts and accessories 4 The user should make sure that the installation is carried out by qualified authorised persons and that these persons have first carefully read the following instructions 5 The operating ...

Page 3: ...o clean or replace EXIT PIPE CYCLONE RH CYCLONE LH TOP SHELL WATER OUTLET 4 PORT MAINFOLD PLATE CYCLONE HOLDER BOTTOM SHELL WATER INLET 4 PORT CLEAR PIPE STAND DRAIN FLUSH VALVE Incoming water is guided by a diverter plate so that it enters multiple hydro cyclones tangentially generating a strong centrifugal effect This spins the sediment out to the hydro cyclone s wall and then spirals it down to...

Page 4: ...st be installed upstream of the filter inlet The PRV should be set to 90 of the maximum operating pressure of the tank If the incoming water flow is less than the filter s minimum flow requirements the filter s filtration efficiency will be affected please consult Waterco MultiCyclone 70XL Recommended Operational Flow Rates Minimum flow rate 36m3 hr 158 5 GPM Maximum flow rate 96 m3 hr 422 7 GPM P...

Page 5: ...he purge valve FLUSHING OUT THE SEDIMENT CHAMBER Whilst the water pump is running simply open the sediment purge valve until the sediment has been flushed out This is visible through the clear sight glass Once the sediment has been flushed out close the sediment purge valve WARRANTY MultiCyclone 70XL is covered by a 2 warranty For more information please refer to the Waterco Warranty Terms Conditi...

Page 6: ... 80 00 100 00 120 00 MultiCyclone 70XL Total Head Loss Curve Head Loss m Flow Rate m3 hr TECHNICAL SPECIFICATION Pressure Rating 250 kPa 2 5 bar 36 psi Minimum Flow Rate 36m3 hr 158 5 GPM Maximum Flow Rate 108 m3 hr 475 6 GPM DIMENSIONS 1359 730 71 654 478 5 740 542 5 ...

Page 7: ...S 025 14 24 O Ring BS 392 1 23 O Ring Special 2 22 Washer BH 100mm 2 21 O Ring BS 474 2 20 Washer M10 96 19 Nut M10 48 18 Clear Pipe 50mm 1 17 2 Way Valve 50mm 1 16 Base 1 15 Elbow 50mm 1 14 Half Union 50mm 1 13 Male Valve Socket 1 12 Lower Shell 1 11 Pipe 100mm 1 10 Elbow 90 100mm 1 9 Pipe 100mm 1 8 Bulkhead 100mm 1 7 Cyclone Holder 1 6 Cyclone Cone RH 35 5 Cyclone Cone LH 35 4 Mainfold Plate 1 3...

Page 8: ...ted Sittingbourne Kent UK Tel 44 0 1795 521 733 Waterco France Saint Priest France Tel 33 4 72 79 33 30 Waterco USA Inc Augusta Georgia USA Tel 1 706 793 7291 Waterco Canada Longueuil Quebec Canada Tel 1 450 748 1421 Waterco NZ Limited Auckland New Zealand Tel 64 9 525 7570 Waterco Limited Guangzhou China Tel 86 20 3222 2180 Waterco Far East Sdn Bhd Selangor Malaysia Tel 60 3 6145 6000 PT Waterco ...