Waterco Multicyclone 70Xl
I pg 03
The accumulation of sediment can be visibly monitored through the MultiCyclone 70XL’s clear pipe.
The MultiCyclone 70XL is cleaned by simply opening the purge valve.
MultiCyclone 70XL is ideal as a pre-filter to extend the life of your existing filter.
• Save Water
• Reduce backwash frequency.
Please Note: the Multicyclone 70Xl is designed to filter sediment that is heavier than water; floating
debris cannot be filtered out by centrifugal filtration.
INSTALLATION
Be sure to comply with the local plumbing codes. The filter may be plumbed into a drinking water
system and would, therefore be subject to whichever local regulations that may apply.
Be sure that all provisions for wastewater disposal meet local, state or national codes. Do not
discharge water where it will cause flooding or damage.
If the incoming water pressure is higher than the maximum operating pressure of 350kPa /3.5Bar
/50psi, a Pressure Regulating Valve (PRV) must be installed upstream of the filter inlet.
The PRV should be set to 90% of the maximum operating pressure of the tank.
If the incoming water flow is less than the filter’s minimum flow requirements, the filter’s filtration
efficiency will be affected, please consult Waterco.
MultiCyclone 70XL Recommended Operational Flow Rates
Minimum flow rate: 36m
3
/hr (158.5 GPM)
Maximum flow rate: 96m
3
/hr (422.3 GPM)
PLUMBING CONNECTION
1. Connect the outlet from your pump to the inlet of the MultiCyclone 70XL.
Glue the plumbing to the Barrel unions and Allow 24 hours for glue (solvent) to set. Ensure
solvents are not excessively applied to fittings as this could run into o-rings and create sealing
problems. Screw the barrel union on to the inlet of your MultiCyclone 70XL and hand tighten.
2. Connect from the outlet of the MultiCyclone 70XL to the inlet of your
filter.
Glue the plumbing to the Barrel unions and Allow 24 hours for glue (solvent) to set. Ensure
solvents are not excessively applied to fittings as this could run into o-rings and create sealing
problems. Screw the barrel union on to the outlet of your MultiCyclone 70XL and hand tighten.
3. Connect to Waste Line.
Glue the plumbing from the Sediment Purge Valve to your waste line.
4. Turn on pump.
Be sure to check that there are no leaks from the connectors. If required, tighten by hand.
FILTER MAINTENANCE
Filter maintenance determined by the following conditions:
1. The flow rate through the MultiCyclone 70XL is insufficient to meet the demand.
The accumulation of sediment can be visibly monitored through the MultiCyclone 70XL’s clear pipe.
The MultiCyclone 70XL is cleaned when the clear pipe is ¾ full of sediment.
FLUSHING OUT THE SEDIMENT CHAMBER
Procedure to purge the Multicyclone 70XL:
1. Open 2 way valve whilst pump running
2. Allow sediments to be flush out from sediment chamber
3. Visually inspect clear pipe
4. If clear pipe is free of debris close 2 way valve.
WARRANTY
MultiCyclone 70XL is covered by a 2 years warranty.
For more information please refer to the Waterco “Warranty Terms & Conditions” booklet. With our
on going commitment to quality products and service Waterco Limited reserves the right to alter the
product in any manner and at any time without prior warning.
This information is to the best of our knowledge, accurate at the time of printing. Any recommendations
or suggestions are made without warranty and without prejudice, since the use of our product is
beyond our control.