background image

Waterco Multicyclone 70Xl

I pg 03

The accumulation of sediment can be visibly monitored through the MultiCyclone 70XL’s clear pipe.  
The MultiCyclone 70XL is cleaned by simply opening the purge valve. 

MultiCyclone 70XL is ideal as a pre-filter to extend the life of your existing filter.

•  Save Water
•  Reduce backwash frequency.

Please Note: the Multicyclone 70Xl is designed to filter sediment that is heavier than water; floating 
debris cannot be filtered out by centrifugal filtration.

INSTALLATION

Be sure to comply with the local plumbing codes. The filter may be plumbed into a drinking water 
system and would, therefore be subject to whichever local regulations that may apply.

Be sure that all provisions for wastewater disposal meet local, state or national codes. Do not 
discharge water where it will cause flooding or damage.

If the incoming water pressure is higher than the maximum operating pressure of 350kPa /3.5Bar 
/50psi, a Pressure Regulating Valve (PRV) must be installed upstream of the filter inlet. 

The PRV should be set to 90% of the maximum operating pressure of the tank.

If the incoming water flow is less than the filter’s minimum flow requirements, the filter’s filtration 
efficiency will be affected, please consult Waterco.

MultiCyclone 70XL Recommended Operational Flow Rates

Minimum flow rate:  36m

3

/hr (158.5 GPM)

Maximum flow rate:  96m

3

/hr (422.3 GPM)

PLUMBING CONNECTION

1. Connect the outlet from your pump to the inlet of the MultiCyclone 70XL. 

  Glue the plumbing to the Barrel unions and Allow 24 hours for glue (solvent) to set. Ensure 

solvents are not excessively applied to fittings as this could run into o-rings and create sealing 
problems. Screw the barrel union on to the inlet of your MultiCyclone 70XL and hand tighten. 

2. Connect from the outlet of the MultiCyclone 70XL to the inlet of your 

filter. 

  Glue the plumbing to the Barrel unions and Allow 24 hours for glue (solvent) to set. Ensure 

solvents are not excessively applied to fittings as this could run into o-rings and create sealing 
problems. Screw the barrel union on to the outlet of your MultiCyclone 70XL and hand tighten.

3. Connect to Waste Line. 

  Glue the plumbing from the Sediment Purge Valve to your waste line.

4. Turn on pump. 

  Be sure to check that there are no leaks from the connectors. If required, tighten by hand.

FILTER MAINTENANCE

 Filter maintenance determined by the following conditions:

1. The flow rate through the MultiCyclone 70XL is insufficient to meet the demand.

The accumulation of sediment can be visibly monitored through the MultiCyclone 70XL’s clear pipe. 
The MultiCyclone 70XL is cleaned when the clear pipe is ¾ full of sediment.

FLUSHING OUT THE SEDIMENT CHAMBER

Procedure to purge the Multicyclone 70XL:

1.  Open 2 way valve whilst pump running

2.  Allow sediments to be flush out from sediment chamber

3.  Visually inspect clear pipe 

4.  If clear pipe is free of debris close 2 way valve. 

WARRANTY

MultiCyclone 70XL is covered by a 2 years warranty.

For more information please refer to the Waterco “Warranty Terms & Conditions” booklet. With our 
on going commitment to quality products and service Waterco Limited reserves the right to alter the 
product in any manner and at any time without prior warning.

This information is to the best of our knowledge, accurate at the time of printing. Any recommendations 
or suggestions are made without warranty and without prejudice, since the use of our product is 
beyond our control.

Summary of Contents for MULTI CYCLONE 70XL

Page 1: ...NSW Sydney Head Office Tel 61 2 9898 8600 QLD Brisbane Tel 61 7 3299 9900 VIC TAS Melbourne Tel 61 3 9764 1211 WA Perth Tel 61 8 9273 1900 SA NT Adelaide Tel 61 8 8244 6000 ACT Distribution Tel 61 2 6280 6476 OFFICES Waterco Europe Limited Sittingbourne Kent UK Tel 44 0 1795 521 733 Waterco France Saint Priest France Tel 33 4 72 79 33 30 Waterco USA Augusta GA USA Tel 1 800 247 7291 Waterco Canada...

Page 2: ...ersons have first carefully read the following instructions 5 The operating safety of the filter is only guaranteed if the installation and operation instructions are correctly followed 6 In the event of defective operation or fault contact Waterco or its nearest authorised service agent 7 To reduce the risk of injury do not permit children to use this product unless they are closely supervised at...

Page 3: ...could run into o rings and create sealing problems Screw the barrel union on to the inlet of your MultiCyclone 70XL and hand tighten 2 Connect from the outlet of the MultiCyclone 70XL to the inlet of your filter Glue the plumbing to the Barrel unions and Allow 24 hours for glue solvent to set Ensure solvents are not excessively applied to fittings as this could run into o rings and create sealing ...

Page 4: ... 4 100mm B U NITRILE W02553 2 27 NUT HEX LONG M10x45mm SS304 W22751 48 26 SPRING WASHER M10 SS304 W22414 48 25 WASHER M10 OD 30 THICKNESS 2 5 SS304 W22651 96 24 SCREW HEX M10x110mm SS304 W22750 48 23 HEXAGON BOLT M6 35 SS304 W22654 60 22 WASHER M6 FLAT SS304 W12782 60 21 O RING 20 2 0 W22626 70 20 O RING BS009 W22628 60 19 O RING 27 2 0 W22627 140 18 O RING BS392 W22629 1 17 SPIGOT MULTI CYCLONE 4...

Reviews: