I
pg 03
Hydroxzone Ozone Generator
2. iNSTaLLaTiON
2.1 PREPARING FOR INSTALLATION
I.
Check for and correct all leaks in plumbing.
II. Balance the pool Water
III. Backwash the filter on retrofit installation.
IV. Shock the pool. Hydroxzone must be used in combination with and approved/registered
sanitiser
V. Turn pump OFF.
VI. Locate section of plumbing where the Venturi Injector needs to be located.
VII. Venturi Injector must be installed after the filter and any other additional equipment installed
in line (e.g. heater or solar)
VIII. The unit must be mounted out of direct contact with the weather.
IX. Hydroxzone must be mounted on a wall in a horizontal orientation as shown below.
Figure 2.1 Hydroxzone Mounting Position
NOTE:
The minimum recommended vacuum at the inlet of the Venturi injector is 2 L/min.
The vacuum can be measure by using a vacuum meter (Waterco’s P/N 72522813). It may
be necessary to install a Ball Valve (not included) in the main line between the Entrance and
Exit of the bypass. The Ball Valve will need to be adjusted to ensure adequate flow through
the bypass.
Multispeed pumps can alter the water flow rate through the pool system. Adjusting the
speed of a Multispeed pump will affect the water flow and the vacuum through the Venturi
Injector.
When making any adjustments to the speed of the Multispeed pump, make sure there is a
minimum vacuum of 2L/min through the venturi injector.
All pools are different. Depending on the hydraulic resistance in the pool system, running a
Multispeed pump on low speed may not create enough vacuum. If this is the case, the pump
speed will need to be increased until the minimum required vacuum is reached.