Waterco Portapac / Delta Hot
FAULT
POSSIBLE CAUSE
ACTION
Portapac
will not run
No power
Check the flexible electrical supply cord is
plugged in and not damaged.
Blown fuse
Check the power circuit fuse or circuit
breaker has not blown or tripped.
RCD tripped
Reset RCD.
Pump impeller jammed
Call service.
Motor burnt out
A strong smell of plastic will be
present if burnt out. Call service.
Air switch
Check air tube is connected and
not blocked/ kinked
(air switch models only).
Touch pad
Check electronic touch pad is
connected to Portapac. If not, call service.
Over-Temperature
Device tripped.
See “ Over-Temperature Device
tripped ” below.
Constantly
Flashing Heater
Indicator Light
(touch pad models)
Over-Temperature
Sensor not
properly connected.
Call service to check Over-
Temperature Sensor connections.
Over-Temperature
Device tripped
Water inside Portapac reached,
and stayed at, 45˚C
(spa water still cold)
Check for and remove blockages
in the filter and pipe-work.
Call service to check for
blockages in the impeller.
Press Over-Temperature RESET.
Water in spa reached 45˚C
Properly secure sensor in
housing (refer to “ Installing the
Temperature Sensor ”).
Press Over-Temperature RESET.
Over-Temperature
Device tripped
shortly after power-
up
Over-Temperature Sensor not
connected or faulty
Call service to connect or replace.
TROUBLESHOOTING
The spa pump should only be serviced by qualified service technicians. However, some
problems can be checked and rectified by the owner before making a service call.
I pg 11