Waterco Aquamaster
I pg 23
If Pool Only is selected
Pool Heating
> Select your heating requirements
> No Heating
> Heat Pump
> Gas Heater
> Solar
Press “Enter” to proceed to configure your selection
If “Gas Heater” or “Heat Pump” is selected the “Gas Heater Settings” or Heat Pump Settings”
Menu will appear.
Is the heater independent of or integrated to the filtration system?
Integrated Conventional Heater
- “Integrated” should be selected for a conventional heater
operating within the filtration circuit.
Independent Conventional Heater
- “Independent” should be selected for a conventional heater
operating separately to the filtration circuit.
Select either the “Independent” or “Integrated” icon relevant to your pool hydraulic configuration.
Press the “Temp Check Period” icon to alter the period between Aquamaster checking the
pool temperature via operation of the filter pump or independent pump. After the desired pool
/ spa temperature is reached the pump switches off but will operate again at the set “Temp
Check Period” monitoring the pool / spa temperature. If the pool / spa are below the desired set
temperature, the pump will remain on and provide water flow to the heater. The period may be set
to check between one and four hours in half hour increments with the default at 2 hours.
Press the “Heater Timer” icon to set the heater operation times.
If “Integrated” is selected a “Heating Demand Option” icon will appear. Effectively, if this function
is activated it will override the filtration pump’s timer setting and will keep the heater heating the
pool water until the set temperature is reached. The Heating Demand Option may be controlled by
the Demand Mode.
Timer which is accessed via the “Demand Mode Timer” icon. Press “Enter” to proceed to configure
your selection.
If “Solar Heating” was selected the “Solar Heating Settings” Menu will appear.
Is the Solar independent of or integrated to the filtration system?
Select either the “Independent” or “Integrated” icon relevant to your solar hydraulic configuration.
Press the “Temp Check Period” icon to alter the period between Aquamaster checking the pool
temperature via operation of the filter pump or independent pump. After the desired pool / spa
temperature is reached the pump switches off. The pump will operate again at the set “Temp
Check Period” monitoring the pool / spa temperature. If the pool / spa are below the desired set
temperature, the pump will remain on and provide water flow to the solar system. The period may
be set to check between one and four hours in half hour increments with the default set at 2 hours.
Solar Preference
The solar heating function may be given priority over other forms of heating by selecting the
“Solar Preference” icon. The “Solar Preference” feature should be selected if the solar heating is
to have operational priority over a conventional heater.