INSTALLATION INSTRUCTIONS

EASY SET UP INSTALLATION OF YOUR NEW SOFTENER

Before beginning installation please ensure:

1

) Pressure reducing valve is fitted to pipe work if site pressure is over 3 bar.

2) Minimum site pressure is Min 1.5 bar – If below we recommend installation       

of pumped softener.

3) A bypass should be fitted and supplied by the installer

4) Only use hoses supplied

Failure to adhere to above may affect the performance of the softener and 

invalidate warranty.

INSTRUCTIONS

- Remove Softener from the box and ensure that all parts are correct.

- Connect hoses to inlet and outlet connections on the back of the valve.

- Connect drain hose and ensure this is sited into a suitable waste outlet using     

  air gap fitting supplied.

- Connect overflow to outside drain.

- Slowly open the inlet valve to allow water to enter softener.

- Turn on electricity supply to softener.

- Check controller displays “BACKWASH” with a time shown in minutes.

- Allow controller to finish “BACKWASH” and enter “BRINE” position.

- When valve stops and displays countdown time on the controller press the         

  regeneration Key to step valve on to “RINSE”

- When in “RINSE” position press regeneration key again to step valve in to  

 

  “REFILL” position.

- Allow unit to count down this shown time. Cabinet will fill with the correct level  

  of water.

- Set day and time and incoming water hardness as per program instructions.

- Slowly open water outlet.

- Ensure bypass is set to closed.

- Check water supply, flow and that protected equipment is working.

- Add tablet salt.

INLET

OUTLET

DRAINAGE

Located under

valve cover

BRINE

Summary of Contents for HS-10

Page 1: ...WATER METERED SOFTENER WARRANTIES HELPFUL HINTS www watercare co uk v1 0 HS 10 HS 14 HS 18 HS 23 HS 30 WaterCare Regal House South Road Harlow CM20 2BL Telephone 01279 780250 Email info watercare co...

Page 2: ...re order your salt via www watercare co uk Check the salt level regularly and ensure it does not fall below the water level Fill the cabinet approximately 2 3 inches from the top with salt when toppi...

Page 3: ...terCare recommends fitting a pressure reducing valve should pressure exceed 3 bar Blocking or kinking of supply or drain hoses Interruption of electricity supply Max temperature is 50 C If the tempera...

Page 4: ...this is sited into a suitable waste outlet using air gap fitting supplied Connect overflow to outside drain Slowly open the inlet valve to allow water to enter softener Turn on electricity supply to...

Page 5: ...l be flashing Press or to adjust value Press to save value and move on to next step SET TIME OF REGENERATION DEFAULT IS 2AM The hour indicator will be flashing Press or to adjust value Press to save v...

Page 6: ...the current time of day and volume of soft water remaining SET THE INCOMING HARDNESS DEFAULT 300PPM The indicator will be flashing Press or to adjust value Press to save value and move on to next digi...

Page 7: ...outh Road Harlow CM20 2BL Telephone 01279 780250 Email info watercare co uk All ourSofteners are 100 Recyclable at end of life Contact WaterCare Recycling on 01279 780250 to find out more www watercar...

Reviews: