INSTALLATION INSTRUCTIONS
EASY SET UP INSTALLATION OF YOUR NEW SOFTENER
Before beginning installation please ensure:
1
) Pressure reducing valve is fitted to pipe work if site pressure is over 3 bar.
2) Minimum site pressure is Min 1.5 bar – If below we recommend installation
of pumped softener.
3) A bypass should be fitted and supplied by the installer
4) Only use hoses supplied
Failure to adhere to above may affect the performance of the softener and
invalidate warranty.
INSTRUCTIONS
- Remove Softener from the box and ensure that all parts are correct.
- Connect hoses to inlet and outlet connections on the back of the valve.
- Connect drain hose and ensure this is sited into a suitable waste outlet using
air gap fitting supplied.
- Connect overflow to outside drain.
- Slowly open the inlet valve to allow water to enter softener.
- Turn on electricity supply to softener.
- Check controller displays “BACKWASH” with a time shown in minutes.
- Allow controller to finish “BACKWASH” and enter “BRINE” position.
- When valve stops and displays countdown time on the controller press the
regeneration Key to step valve on to “RINSE”
- When in “RINSE” position press regeneration key again to step valve in to
“REFILL” position.
- Allow unit to count down this shown time. Cabinet will fill with the correct level
of water.
- Set day and time and incoming water hardness as per program instructions.
- Slowly open water outlet.
- Ensure bypass is set to closed.
- Check water supply, flow and that protected equipment is working.
- Add tablet salt.
INLET
OUTLET
DRAINAGE
Located under
valve cover
BRINE