To shut down and store the B2X-18/23 unit: 

1.  Shut down the pump. 

a.  Gradually reduce the engine speed. 

b.  Whenever the unit has been run at full throttle for most of the operation, allow the valves to remain slightly 

open and run the engine at idle for approximately 2 minutes before shutting down the unit. 

c.  If the unit is to be stored, move the fuel valve lever to the OFF position and wait for the engine to stop. 

Otherwise, set the ignition switch to the OFF position to shut down the engine. 

d.  Close off the hydrant/supply to the pump.  

e.  Open all valves to relieve any pressure left in the system. 

2.  Check and store the pump. 

a.  If the pump was last run with foam or water that is salty, brackish or high in mineral content, flush the pump 

with fresh water for a minimum of 2 minutes or until the water is clear. 

b.  After the unit has cooled down, check all fluid levels and add as needed.  

c.  Completely drain the pump of all water. 

d.  Break down and store all equipment as outlined by the apparatus or department procedures. 

e.  Visually inspect the pump end. Clean any dirt or debris from the pump unit. If necessary, a mild soap and 

water solution can be used. Note and report any performance irregularities or any abnormal mechanical 

sounds. 

f.  Close all valves and plug all openings. 

g.  Follow any other product, component, apparatus, and departmental procedures and/or guidelines before 

placing the unit in storage. Make sure all necessary tools, spares, and accessories are with the pump. 

 

To operate the B2X-18/23 unit in cold weather: 

  The pump can be run in below freezing temperatures if certain precautions are taken to avoid the formation of 

ice in the pump.  

  After priming the pump, the unit should be run at low speed for a short period of time to allow all components 

to warm up before continuing with the remaining operating procedures. 

  Unless wrapped in a heater, drain the pump of all water if it is stopped for any length of time. The engine/drive 

unit should be turned over a few revolutions to make sure all water has been removed from the pump. Drain 

the pump priming line if a primer has been used.  

  After use, drain the pump, manifolds, and lines of all water. You can also pour some antifreeze into the pump 

and circulate it through the pump and plumbing system. 

 