background image

Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System 

 

Copyright © 2019 WaterAnywhere  

All Rights Reserved.

 

Page 7 

 

 

Step 1 - Drill a Hole into the Sink for the Faucet   

 

 

 

 

 Notice:

 

If your sink is equipped with a pre-drilled 1 ¼” or 1 ½” hole suitable for the faucet 
installation, you may skip to step 2. 

 

 

 Notice:

 

Manufacturer assumes no responsibility for damages resulting from installing faucets 
into any surface.  It is recommended to use a licensed contractor for this step. 

 

 

For this, step, you will need: 

  Masking tape or duct tape 

  Variable speed drill with 

” and 7/16” drill bits 

  1-¼” hole saw bit for faucet opening – appropriate for the surface you are drilling 

 

Determine the desired location for your RO Faucet 

The product water faucet may be installed on any flat surface at least 2” in diameter.  Check the underside 
of the location for interference.  The standard faucet that is supplied with the system requires a ½” diameter 
hole.  The optional air-gap faucet requires a larger hole of ¾” to allow for the additional tubing connections 
required. 
 

Stainless Steel Sinks 

Begin by placing a piece of masking tape or duct tape on the determined location where the hole is to be 
drilled.  Make a small indent to mark the desired drilling location using a center punch.  Drill a pilot hole with 

” metal drill bit.  Enlarge the hole using a ¼” metal drill bit, using factory approved method or approved 

plumbing practice. 
 

Porcelain/Enamel Sinks or Tile Countertop 

Sinks of this type are very easy to damage due to the nature of the materials of construction.  A successful 
installation into these sinks requires a knowledgeable technician with the proper cutting tools.  We strongly 
recommend the use of a “Relton” type device.  Follow the directions that accompany the tool carefully. 

 

 

 

Summary of Contents for AAA-RO200W

Page 1: ...ywhere com 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 5 Stage Point of Use Reverse Osmosis Drinking Water System Document ID AAARO200W Revision 05 13 20...

Page 2: ...e 4 2 Reverse Osmosis Membranes Replace every 12 months The fourth stage is the reverse osmosis membrane which is the heart of the RO system To achieve a higher product water flow the water stream is...

Page 3: ...ousings onto System Manifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Installation Steps Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step...

Page 4: ...water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologically u...

Page 5: ...housing D Housing with RO Membrane 2 in parallel E Four way Valve F In Line Cartridge with Activated Carbon G Flow Restrictor H Tank Valve I Tank J Faucet 1 Clean Water Outlets 2 Pollutants Outlets 3...

Page 6: ...er hazards Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system to the hot water supply line will permanently damage the membrane s...

Page 7: ...s and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause...

Page 8: ...ace at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires a lar...

Page 9: ...k top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by threadin...

Page 10: ...e drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not drill through to the o...

Page 11: ...sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball valve int...

Page 12: ...t all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metallic ta...

Page 13: ...em seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the conn...

Page 14: ...Replace every 3 6 months Other Replacement Components Part Image H H14FWWA Filter Housing Standard 10 White FNPT PV2012PME Membrane Housing FNPT H S3200PW Storage Tank 3 2 gallon H R1000QC 100 GPD Flo...

Page 15: ...to rinse the filter housings Leave the faucet open until the filter change is complete 1 Remove pre filters from filter housings Use a filter wrench if the housings are too tight 2 Discard used filte...

Page 16: ...pump may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that you...

Page 17: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Page 18: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Page 19: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Page 20: ...nt Pre filter Carbon Pre filter x 2 Carbon Post Filter Sediment Pre filter Carbon Pre filter x 2 Sediment Pre filter Carbon Pre filter x 2 Carbon Post Filter RO Membrane x 2 Sanitize System Replacemen...

Reviews: