background image

Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System 

 

Copyright © 2019 WaterAnywhere  

All Rights Reserved.

 

Page 14 

 

 

System 

Maintenance          

 Notice:

 

If your RO system is connected to an icemaker or other equipment, you must turn off 
the connection to the equipment before performing any maintenance. 

 

Membrane Replacement Instructions 

The membranes should be replaced every 1-2 years, depending on the water quality. 

 
Before starting, shut off the cold water supply to the unit.   Lift the handle on the faucet to drain out the storage 
tank completely and allow the system to stand for 10 minutes in order to fully decompress the tank.   Leave the 
faucet open until the membrane change is complete. 

 

1.  Unscrew the fitting to the cap then remove the cap of each membrane housing.  Use the membrane 

wrench if the cap is too tight. 

2.  Using pliers, pull out the old membranes from the housings.     
3.  Remove the new membranes from their bags.  
4.  Insert one membrane into each housing in the same direction as the old membrane.  
5.  Push the membrane firmly into the housing until it seats on the far end.  
6.  Screw the housing caps back on, making sure the o-ring is positioned correctly.  
7.  Screw the fittings (with tubing) back onto the housing.  
8.  The system is ready. Turn on the water supply. Check for any leaks. 
9.  Drain the first two tanks of water before drinking. 

Filter Replacement Instructions 

All pre and post-filters should be replaced every 3-6 months.

 

 
Before starting, shut off cold water supply to unit.   Lift the handle on the faucet to drain out the storage tank 
completely and allow the system to stand for 10 minutes in order to fully decompress the tank, reserving some 
of the RO water to use to rinse the filter housings.   Leave the faucet open until the filter change is complete. 

 

1.  Remove pre-filters from filter housings.  Use a filter wrench if the housings are too tight.  
2.  Discard used filters, but save o-rings for re-use.  
3.  Clean inside of all housings with a mild soap solution, and then rinse with RO water.  
4.  Lubricate the o-ring and replace in filter housing. 
5.  Insert the new filters into the appropriate housings and replace the housings onto the system. 
6.  Disconnect the post-filter by removing the fittings on either end.  Replace with new post-filter and re-use 

the existing fittings.  

(Feed end tee is connected by a short length of tubing, remove this and use to connect to new filter.)

 

7.  Follow the normal Start-up Procedures.  (Drain the first tank of water after changing the filters before 

drinking.) 

Sanitizing 

We recommend sanitizing the system at least once a year.  This can be done while changing your filters. Shut 
down the system.   If you have an icemaker hook-up installed, be sure the ball valve in the line to the 
refrigerator is in the closed position during this procedure.   Open the faucet to drain the system, including the 
tank.  Remove the pre-filter cartridges and RO Membranes from the system, leaving the old post-filter cartridge 
in place.   Wash the internal filter housing & membrane housing areas with warm soapy water and rinse well to 
remove the soap.  Pour about ¼ teaspoon of Hydrogen Peroxide or household bleach into each filter housing 
and replace housings on the RO system. Open the feed water valve and open the RO faucet until water flows 
freely from the spout.  Close the faucet and hold the solution in the system for a minimum of 10 minutes. 
Drain the tank completely, close the faucet to allow tank to fill again, and then drain again.  Replace filters and 
membrane as indicated in the replacement instructions.  The post filter should be changed after sanitizing the 
system. 

Summary of Contents for AAA-RO200W

Page 1: ...ywhere com 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 5 Stage Point of Use Reverse Osmosis Drinking Water System Document ID AAARO200W Revision 05 13 20...

Page 2: ...e 4 2 Reverse Osmosis Membranes Replace every 12 months The fourth stage is the reverse osmosis membrane which is the heart of the RO system To achieve a higher product water flow the water stream is...

Page 3: ...ousings onto System Manifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Installation Steps Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step...

Page 4: ...water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologically u...

Page 5: ...housing D Housing with RO Membrane 2 in parallel E Four way Valve F In Line Cartridge with Activated Carbon G Flow Restrictor H Tank Valve I Tank J Faucet 1 Clean Water Outlets 2 Pollutants Outlets 3...

Page 6: ...er hazards Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system to the hot water supply line will permanently damage the membrane s...

Page 7: ...s and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause...

Page 8: ...ace at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires a lar...

Page 9: ...k top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by threadin...

Page 10: ...e drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not drill through to the o...

Page 11: ...sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball valve int...

Page 12: ...t all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metallic ta...

Page 13: ...em seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the conn...

Page 14: ...Replace every 3 6 months Other Replacement Components Part Image H H14FWWA Filter Housing Standard 10 White FNPT PV2012PME Membrane Housing FNPT H S3200PW Storage Tank 3 2 gallon H R1000QC 100 GPD Flo...

Page 15: ...to rinse the filter housings Leave the faucet open until the filter change is complete 1 Remove pre filters from filter housings Use a filter wrench if the housings are too tight 2 Discard used filte...

Page 16: ...pump may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that you...

Page 17: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Page 18: ..._____________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Page 19: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Page 20: ...nt Pre filter Carbon Pre filter x 2 Carbon Post Filter Sediment Pre filter Carbon Pre filter x 2 Sediment Pre filter Carbon Pre filter x 2 Carbon Post Filter RO Membrane x 2 Sanitize System Replacemen...

Reviews: