Installation and Service Manual – Under-the-Counter Point of Use 6 Stage Reverse Osmosis System with Pump & UV 

 

Copyright © 2020 WaterAnywhere. 

All Rights Reserved.

 

Page 14 

 

 

 System Maintenance 

 

 Notice:

 

Unplug the Pump & UV before perorming any maintenance to the system. 

 

 

 

 

 

 Notice:

 

If your RO system is connected to an icemaker or other equipment, you must turn off 
the connection to the equipment before performing any maintenance. 

 

Membrane Replacement Instructions 

The membrane should be replaced every 1-2 years, depending on the water quality. 

 
Before starting, shut off the cold water supply to the unit and unplug the UV system.   Lift the handle on the 
faucet to drain out the storage tank completely and allow the system to stand for 10 minutes in order to fully 
decompress the tank.   Leave the faucet open until the membrane change is complete. 

 

1.  Unscrew the fitting to the cap of the membrane housing.  Use the membrane wrench if the cap is too tight. 
2.  Using pliers, pull out the old membrane from the housing.     
3.  Remove the new membrane from its bag.  
4.  Insert the membrane in the housing in the same direction as the old membrane.  
5.  Push the membrane firmly into the housing until it seats on the far end.  
6.  Screw the housing cap back on, making sure the o-ring is positioned correctly.  
7.  Screw the fitting (with tubing) back onto the housing.  
8.  The system is ready. Turn on the water supply. Check for any leaks. 
9.  Drain the first two tanks of water before drinking. 

Filter Replacement Instructions 

All pre and post-filters should be replaced every 3-6 months.

 

 
Before starting, shut off cold water supply to unit and unplug the UV system.   Lift the handle on the faucet to 
drain out the storage tank completely and allow the system to stand for 10 minutes in order to fully decompress 
the tank, reserving some of the RO water to use to rinse the filter housings.   Leave the faucet open until the 
filter change is complete. 

 

1.  Remove pre-filters from filter housings.  Use a filter wrench if the housings are too tight.  
2.  Discard used filters, but save o-rings for re-use.  
3.  Clean inside of all housings with a mild soap solution, and then rinse with RO water.  
4.  Lubricate the o-ring and replace in filter housing. 
5.  Insert the new filters into the appropriate housings and replace the housings onto the system. 
6.  Disconnect the post-filter by removing the fittings on either end.  Replace with new post-filter and re-use 

the existing fittings.  

(Feed end tee is connected by a short length of tubing, remove this and use to connect to new filter.)

 

7.  Follow the normal Start-up Procedures.  (Drain the first tank of water after changing the filters before 

drinking.) 

 

Ultraviolet (UV) System Maintenance 

 Warning!

 

  Always disconnect power before performing any work on the disinfection system. 

  Always shut-off water flow and release water pressure before servicing. 

  Regularly inspect your disinfection system to ensure that the power indicators are on. 

  Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum 

disinfection. 

  Always unplug the UV system and drain the chamber when closing a seasonal home or 

leaving the unit in an area subject to freezing temperatures. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AAA-RO100PUVW

Page 1: ...om 760 727 1652 sales wateranywhere com Manual for Installation Operation and Maintenance of 6 Stage Point of Use RO UV Drinking Water System with Pump Document ID AAAROPUVW Revision 05 13 20 AAA RO50...

Page 2: ...he RO membrane the heart of the RO system substantially reduces the total dissolved solids TDS from the water including arsenic barium cadmium chromium hexavalent chromium trivalent copper turbidity f...

Page 3: ...ifold 5 Prepare Tubing 6 Quick Connect Fittings and Tubing Connections 6 Step 1 Drill a Hole into the Sink for the Faucet 7 Step 2 Faucet Installation 8 Step 3 Drain Saddle Installation 9 Step 4 Syste...

Page 4: ...e of a water softener for hard water supplies will increase membrane life and efficiency Warnings Only use this system on potable water supplies Do not use this system where the water is microbiologic...

Page 5: ...ng D Housing with the RO Membrane E Tank Shut Off Valve F Four way Valve G In Line Cartridge with Activated Carbon H Flow Restrictor I Tank Valve J Tank K UV System L Faucet 1 Clean Water Outlet 2 Pol...

Page 6: ...pplies UV Controller should be mounted to the wall see System Mounting section Determine the location of the cold water feed line to use for the system supply Notice Accidentally hooking up the system...

Page 7: ...ings and Tubing Connections To ensure a secure seal using quick connect fittings Cut tubing with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cau...

Page 8: ...t surface at least 2 in diameter Check the underside of the location for interference The standard faucet that is supplied with the system requires a diameter hole The optional air gap faucet requires...

Page 9: ...p or sink top and let it rest on the sink top From the underside of the sink slide the washers onto the threaded stem as shown in the diagram 4 5 made of rubber 6 made of metal Secure the assembly by...

Page 10: ...e Starting with the drill bit drill a hole in the drain pipe Use the drill bit to enlarge the hole Clean the debris from the pipe and the hole before continuing Notice Take extreme caution to not dril...

Page 11: ...on the sink faucet to drain water and relieve pressure from the lines Assemble the Ball Valve Adapter Kit Use Teflon tape to wrap the threads of the ball valve approximately 3 wraps Screw the ball val...

Page 12: ...re that all tubing and fittings used for RO product water are poly material and not copper Due to RO product water being very pure it can leach the minerals from copper tubing which will cause a metal...

Page 13: ...should illuminate without any alarms Wait 5 minutes for UV lamp to reach full power Slowly turn the feed valve counterclockwise until fully open the handle should be in line with the tubing as it ent...

Page 14: ...L Replace every 12 months Quartz Sleev Model QS 212 Replace as needed during lamp change Part Image 8851 2J03 B423 Booster Pump TACS 114 48 Pump Power Supply PSW240 Shut Off Switch LPS340G Low Pressur...

Page 15: ...tions All pre and post filters should be replaced every 3 6 months Before starting shut off cold water supply to unit and unplug the UV system Lift the handle on the faucet to drain out the storage ta...

Page 16: ...V lamp in upward direction from the UV chamber and lamp connector base Hold the UV lamp at the ceramic ends Insert the new UV lamp fully into the UV chamber leaving about two inches of the UV lamp pro...

Page 17: ...with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be completely cleaned or it is scratched or cracked then replace the sleeve Reinstall the qu...

Page 18: ...oap Pour about teaspoon of Hydrogen Peroxide or household bleach into each filter housing and replace housings on the RO system Open the feed water valve and open the RO faucet until water flows freel...

Page 19: ...ed in your unit is rated at 77 F and 60psi Water production will decrease approximately 1 5 for each degree that your incoming water is below 77 F It may be necessary to change to a higher flow membra...

Page 20: ...his system contains a UV Lamp Do not operate the UV Lamp when it is removed from the chamber Unintended use or damage of the system may result in the exposure of dangerous UV radiation UV radiation ma...

Page 21: ...min If these parameters are not being met please check the following Is the system receiving adequate feed water The pump s inlet chamber must be flooded to prevent performance robbing air ingestion...

Page 22: ...____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _________________...

Page 23: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR...

Page 24: ...ent Prefilter Stage 1 2 H F2510AC Carbon Block Pre filters Stages 2 3 1 H F1032 43A Carbon Post Filter Stage 5 with QC adapters RFK 5 PRE Pre Filter Pack Membrane Sold Separately Includes 1 H F1005CF...

Reviews: