Installation and Service Manual – Under-the-Counter Point of Use 6 Stage Reverse Osmosis System with Pump & UV
Copyright © 2020 WaterAnywhere.
All Rights Reserved.
Page 12
System Mounting
Wall mounting is recommended for this system. Dry wall anchors and screws may be necessary (not included
with the system).
Mark screw locations at the desired positions. Use the two holes on the back of the RO System mounting
bracket for marker guides.
Screw the screws into the mounting wall on the marked positions. Use an anchoring device appropriate for
the type of material you are screwing into.
Hang the purification system onto the screws by the holes on the back of the unit.
Mount the UV controller horizontally to the wall, near the UV chamber.
Ideally place the controller above the chamber and away from any
water connection point, to prevent any water from potentially leaking
onto the controller by means of a leak at a connection point or a
“sweating” system. Make sure you allow for a “drip-loop” as shown in
the following diagram on the UV lamp, UV sensor, and power cord,
again, to prevent any water from potentially entering the controller.
Turning the System On for the
First
Time
Make sure all water supply and drain line connections are secure and free from leaks.
Plug the system into the ground fault interrupter and check controller to ensure the system is operating
properly. The controller should illuminate without any alarms. Wait 5 minutes for UV lamp to reach full power.
Slowly turn the feed valve counterclockwise until fully open (the handle should be in line with the tubing as it
enters the connection). Check the stem seal for leakage. If necessary, tighten stem nut lightly.
Plug the pump transformer cord into an electrical outlet.
Turn storage tank valve one quarter turn counterclockwise to open the valve (the handle should be in line with
the tubing as it enters the connection).
Open the product water faucet and let the water flow until all the air has been expelled from the system. This
will take about an hour.
Close the product water faucet. In 30 minutes, check the system and connections for leaks and correct if
necessary.
Do Not Use the First Two Reservoirs of Water
Allow the reservoir to fill for 4-6 hours. Dispense this water to drain. This process
removes the factory installed sanitizing solution from the entire system and sends it to
the drain. Repeat this process one more time. Allow the tank to fill for 4-6 hours and
dispense this water to the drain. Do not drink this water!
Notice:
Air bubbles may be present in the product water after initial system startup, causing
a milky color in the water. This is normal and safe to drink. The air bubbles will
disappear within a few days of regular use.
Notice:
Check back frequently in the first 24 hours to ensure no leaking has occurred.
Notice:
When there is no flow, the water in the UV cell will become warm, as the UV lamp is
always on. To remedy this, run cold water for a minute to flush out the warm water.