background image

STARTING UP THE SYSTEM

8

Flushing, Conditioning and Sanitizing

    

 

 

 

 

Did you connect the drain line securely to the valve?

 

 

 

 

Did you connect the brine line securely to the valve?

Step 1.

 Make sure the system is in the “Bypass” position before turning the main water

 

back on. See page 13. Make sure the drain line provided is connected securely to the  

 

control valve and is properly located over a drain. It is recommended that a separate  

 

drain line, not provided, is connected to the overflow elbow on the brine tank and is  

 

properly located over a drain. Make sure the brine line is connected to both the air   

 

check in the brine well and the control valve. Make sure the control valve is plugged  

 

into an operating outlet with the correct voltage and is properly grounded.

Step 2.

Press and Hold the REGEN button on the Triton valve until you hear the motor        

 

engage. This will initiate an immediate manual regeneration of the system. Turn the  

 

bypass valve to Diagnostic Mode (figure 3 on page 13). The screen will indicate    

 

“FILL”. You should hear water entering the system, fill the mineral tank and then    

 

begin filling the brine tank. Wait a few minutes to ensure the control valve pushes    

 

water to brine tank. You should see the water level in the brine tank increasing as    

 

the system puts water in brine tank to make brine. If everything is working, and you  

 

have verified that water in brine tank is rising, press and release the REGEN button.  

 

You will hear the motor engage and move the piston into the “SOFTENING” position.  

 

Check all connections to make sure the system has no leaks. To advance to the next  

 

stage of regeneration, press and release the REGEN button. You will hear the motor  

 

engage and move the piston into the “DRAW” position. You should see the water    

 

level in the brine tank decreasing as the system draws water from brine tank to    

 

regenerate the mineral tank. If everything is working, and you have verified that    

 

water in brine tank is dropping, press and release the REGEN button. Check all  

 

 

connections to make sure the system has no leaks. You will hear the motor engage   

 

and move the piston into the “BACKWASH” position. You should see and hear water  

 

going through the drain line to the drain. Allow the system to backwash until the    

 

water going to drain is clear. If everything is working, and you have verified that    

 

water is going to drain via drain line, press and release the REGEN button. Check all  

 

connections to make sure the system has no leaks. You will hear the motor engage   

 

and move the piston into the “RINSE” position. You should see and hear water going  

 

through the drain line to the drain. If everything is working, and you have verified    

 

that water is going to drain via drain line, press and release the REGEN button.    

Summary of Contents for Softmax Pro SMX10

Page 1: ...OWNERS MANUAL Whole House Water Softener With Triton Electronic Control Valve Activate your warranty by registering your product at watertech com or call 469 521 1180...

Page 2: ...y if high water usage is expected due to guests heavy laundry or other reasons DO contact your WaterTech Dealer if you have any questions about the operation of your system or water quality issues DO...

Page 3: ...mbled 18 x 33 Brine Tank Assembled 18 x 40 Brine Well Assembly for 18x33 Brine Overflow Elbow PART NUMBER 09 03 1054BLK XE 09 03 1252BLK XE 09 03 1354BLK XE 09 04 1833BKNG SIL 09 04 1840BKNG SIL 09 04...

Page 4: ...e time is set press CLOCK SETTING HARDNESS Enter the Installer Screens by pressing and holding simultaneously for 3 5 seconds Once the display changes if the system is programmed to calculate grains o...

Page 5: ...to function properly This is a rarely encountered malfunction DISPLAYS PROGRAMMING SETTING REGENERATION TIME Enter the Installer Screens by pressing and holding simultaneously for 3 5 seconds Once the...

Page 6: ...n and that there is power at the receptacle If the unit does not respond with power present contact your WaterTech Dealer The manual bypass valve which is located at the rear of the unit is designed t...

Page 7: ...e faucets Conditioned water in Check local codes for minimum run between unit and water heater Hot Cold Hot water heater Triton Bypass Valve IMPORTANT Brass or Plastic yoke assembly not shown is requi...

Page 8: ...e directly into drain sewer line or trap Always allow an air gap of at least 25mm 1 inch or 2 pipe diameters between the drain line and waste water to prevent the possibility of sewage being back siph...

Page 9: ...stem puts water in brine tank to make brine If everything is working and you have verified that water in brine tank is rising press and release the REGEN button You will hear the motor engage and move...

Page 10: ...this cycle and also the RINSE cycle which will come next Once the valve has completed the RINSE cycle it will automatically return to SOFTENING In step 5 you will set the valve to Regen Today so that...

Page 11: ...e time is set press CLOCK SETTING HARDNESS Enter the Installer Screens by pressing and holding simultaneously for 3 5 seconds Once the display changes if the system is programmed to calculate grains o...

Page 12: ...ess to move the cursor to adjust the minutes Use or to adjust the minutes Advance to the next Installer Screen by pressing OR you can return to the home display by pressing ERROR MESSAGE SOFT RESET to...

Page 13: ...onding Bypass Valve Instructions on the following page Figure 1 Normal Operation Position The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control va...

Page 14: ...er enters Supply water exits Supply water enters Supply water exits Supply water enters No water exits Supplywater is shut off from the house and valve FIGURE 1 NORMAL OPERATION FIGURE 2 BYPASS OPERAT...

Page 15: ...upon factory inspection within the warranty period the resin is found to be defective Water Tech Industries will furnish replacement resin The resin warranty does not cover resins subjected to water...

Page 16: ...ontinuously Fulfillment of the warranty coverage by WTI is contingent on proper execution of the procedures set forth in the WTI Warranty RGA policy No person or representative is authorized to assume...

Reviews: