CLOCK / HOME

RIGHT / NEXT

LEFT / BACK

DISPLAYS & PROGRAMMING

SETTING REGENERATION TIME

 

Enter the Installer Screens by pressing and holding        

+

       simultaneously for 

 

3-5 seconds.

 

Once the display changes, press        until you reach the “Regeneration Time” display.  

 

When on the “Regeneration Time” display, use        or       to adjust the hour. The hours will  

 

cycle through AM and PM. 

 

Press        to move the cursor to adjust the minutes. Use       or       to adjust the minutes. 

 

Advance to the next Installer Screen by pressing        OR you can return to the home display  

 

by pressing

ERROR MESSAGE

SOFT RESET (to reset “ERROR” code)
Press and hold       

+

 REGEN simultaneously for 3-5 seconds until valve resets.

If the word “ERROR” persists, afer a soft reset, and a number are alternately flashing on the 
display, contact an authorized WaterTech dealer for service help. This indicates that the valve 
was not able to function properly. This is a rarely encountered malfunction.  

Summary of Contents for Softmax Pro SMX10

Page 1: ...OWNERS MANUAL Whole House Water Softener With Triton Electronic Control Valve Activate your warranty by registering your product at watertech com or call 469 521 1180...

Page 2: ...y if high water usage is expected due to guests heavy laundry or other reasons DO contact your WaterTech Dealer if you have any questions about the operation of your system or water quality issues DO...

Page 3: ...mbled 18 x 33 Brine Tank Assembled 18 x 40 Brine Well Assembly for 18x33 Brine Overflow Elbow PART NUMBER 09 03 1054BLK XE 09 03 1252BLK XE 09 03 1354BLK XE 09 04 1833BKNG SIL 09 04 1840BKNG SIL 09 04...

Page 4: ...e time is set press CLOCK SETTING HARDNESS Enter the Installer Screens by pressing and holding simultaneously for 3 5 seconds Once the display changes if the system is programmed to calculate grains o...

Page 5: ...to function properly This is a rarely encountered malfunction DISPLAYS PROGRAMMING SETTING REGENERATION TIME Enter the Installer Screens by pressing and holding simultaneously for 3 5 seconds Once the...

Page 6: ...n and that there is power at the receptacle If the unit does not respond with power present contact your WaterTech Dealer The manual bypass valve which is located at the rear of the unit is designed t...

Page 7: ...e faucets Conditioned water in Check local codes for minimum run between unit and water heater Hot Cold Hot water heater Triton Bypass Valve IMPORTANT Brass or Plastic yoke assembly not shown is requi...

Page 8: ...e directly into drain sewer line or trap Always allow an air gap of at least 25mm 1 inch or 2 pipe diameters between the drain line and waste water to prevent the possibility of sewage being back siph...

Page 9: ...stem puts water in brine tank to make brine If everything is working and you have verified that water in brine tank is rising press and release the REGEN button You will hear the motor engage and move...

Page 10: ...this cycle and also the RINSE cycle which will come next Once the valve has completed the RINSE cycle it will automatically return to SOFTENING In step 5 you will set the valve to Regen Today so that...

Page 11: ...e time is set press CLOCK SETTING HARDNESS Enter the Installer Screens by pressing and holding simultaneously for 3 5 seconds Once the display changes if the system is programmed to calculate grains o...

Page 12: ...ess to move the cursor to adjust the minutes Use or to adjust the minutes Advance to the next Installer Screen by pressing OR you can return to the home display by pressing ERROR MESSAGE SOFT RESET to...

Page 13: ...onding Bypass Valve Instructions on the following page Figure 1 Normal Operation Position The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control va...

Page 14: ...er enters Supply water exits Supply water enters Supply water exits Supply water enters No water exits Supplywater is shut off from the house and valve FIGURE 1 NORMAL OPERATION FIGURE 2 BYPASS OPERAT...

Page 15: ...upon factory inspection within the warranty period the resin is found to be defective Water Tech Industries will furnish replacement resin The resin warranty does not cover resins subjected to water...

Page 16: ...ontinuously Fulfillment of the warranty coverage by WTI is contingent on proper execution of the procedures set forth in the WTI Warranty RGA policy No person or representative is authorized to assume...

Reviews: