Maintenance

This manual is applicable to one of the following model numbers:

Classic Series: 

RC32-TM, RC40-TM, RC48-TM, RC64-TM, RC80-TM  

Platinum Series: 

RP32-TM, RP40-TM, RP48-TM, RP64-TM, RP80-TM

Fusion Series:  

RF32-TM,  RF40-TM,  RF48-TM 

 

With  minimal  care,  your  system  is  designed  to  serve  you  for  many  years.  While  constant  attention  to 

your system is not necessary, the following suggestions will insure your system’s performance and your 

convenience and satisfaction.

MAINTENANCE

•  Salt  in  the  brine  tank  is  used  as  a  resin  ‘cleaner’  to  remove  contaminants  during  the  regeneration 

process. Check the salt level of the brine tank on a regular basis to make sure your system is using salt. 
Your REIONATOR

®

 will function properly whether the salt tank is near full or near empty, refill when 

necessary.

•  Use only premium-grade regenerant salt that is designed specifically for use with water softeners and 

conditioners. Sodium (NaCl) salt may be used. Potassium (KCl) is recommended in most applications for 
superior taste, odor, aesthetic and environmental benefits.

SERVICE ISSUES

•  If the 

Triton control valve

 system display does not appear, check to make sure the system is plugged in 

and that there is power at the receptacle. If the unit does not respond with power present, contact your 
WaterTech Dealer.

• The 

manual bypass valve

 (which is located at the rear of the unit) is designed to isolate the unit from the 

plumbing for servicing or to shut off the water supply to the unit in the event of a leak at the conditioner. 
Consult the operating diagram on pages 11-12 of this manual for instructions to position your bypass 
valve for either service or isolation.

•  If you experience an 

extended power outage

 (over an hour in length), you may need to reset the time of 

day on the Triton control valve. The internal battery is designed to retain the time of day for up to 24 
hours. There is no need to reset any other part of the program as this is kept in non-volatile, permanent 
memory. Consult the programming instructions on page 10 of this manual for instructions to set the 
electronic time clock of the Triton control valve.

•  If you experience a 

change in water quality

:

1.  First check to see if your brine tank is empty (see above). If necessary, add regenerant salt.
2.  Check to see if your system has power (see above).
3.  Check to see if the drain line has a kink that may be restricting flow during regeneration. Correct, if 

necessary, or contact your WaterTech Dealer.

2

Summary of Contents for RC32-TM

Page 1: ...latinum Series Classic Series ACTIVATE YOUR WARRANTY BY REGISTERING YOUR PRODUCT AT www watertech com or call 888 254 8412 WQA Gold Seal certified to NSF ANSI Standards 42 and 44 for meeting or exceed...

Page 2: ...use in brine tank Customer knows where to purchase regenerant salt or potassium chloride Customer knows how often to check regenerant salt potassium level Customer knows how much salt or potassium chl...

Page 3: ...heck to make sure the system is plugged in and that there is power at the receptacle If the unit does not respond with power present contact your WaterTech Dealer The manual bypass valve which is loca...

Page 4: ...ndry or other reasons DO contact your WaterTech Dealer if you have any questions about the operation of your system or water quality issues DO enjoy all the benefits of your REIONATOR conditioned wate...

Page 5: ...sin Tank 10 x 47 09 03 1047BLK Resin Tank 10 x 54 09 03 1054BLK Resin Tank 12 x 52 09 03 1252BLK Resin Tank 13 x 54 09 03 1354BLK Brine Tank Assembled 18 x 33 09 04 1833BKC Brine Grid 18 09 04 119 Bri...

Page 6: ...TION PART NUMBER Resin Tank 10 x 35 09 03 1035NB Resin Tank 12 x 35 09 03 1235NB Fusion Cabinet Top 09 05 010 Fusion Cabinet Base 09 05 011 Brine Overflow Elbow 07 05 004 Brine Well Assembly 09 04 244...

Page 7: ...G KRW ZDWHU KHDWHU 7ULWRQ SDVV 9DOYH Typical Plumbing Installation STOP Check local codes for minimum run between Reionator unit and water heater 6 IMPORTANT Brass or plastic yoke assembly not shown i...

Page 8: ...be Insert Drain Elbow Locking Clip 7 CAUTION Never connect drain line directly into drain sewer line or trap Always allow an air gap of at least 25mm 1 inch or 2 pipe diameters between the drain line...

Page 9: ...ng brine Continue to skip cycles by pressing and releasing the REGEN button wait for the motor to stop before pressing REGEN until you reach the Brine Fill position This ensures that water will go to...

Page 10: ...lding run for several minutes to purge the unconditioned water out of the pipes After several minutes take a water sample and test for hardness from the running tap If a hardness test reads soft water...

Page 11: ...s for This is usually referred to as manual regeneration although it is only started manually If there is a period of heavy water usage because of guests or a heavy laundry day for example a manual re...

Page 12: ...l not need to be reprogrammed STEP 1 Press SET CLOCK STEP 2 Current Time hour Set the hour of the day using the 5 or 6 buttons AM PM toggles after 12 Press NEXT to go to step 3 STEP 3 Current Time min...

Page 13: ...ss valve illustrations on the following page Figure 1 Normal Operation Position The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve Water...

Page 14: ...Bypass Valve Illustrations FIGURE 1 NORMAL OPERATION POSITION FIGURE 2 BYPASS OPERATION POSITION FIGURE 3 DIAGNOSTIC MODE POSITION FIGURE 4 SHUT OFF MODE POSITION 13...

Page 15: ...F 110 F or 4 4 43 3 C MAX FLOW TO DRAIN DURING REGENERATION 2 2 gpm or 8 3 l min INPUT VOLTAGE 110 120VAC 60Hz OPERATING VOLTAGE 12VAC 60Hz 14 Model 1 Softening Efficiency Stated Salt Setting Grains P...

Page 16: ...he concentration of the substance in the water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified by NSF ANSI Stan...

Page 17: ...16 Notes...

Page 18: ...17 Notes...

Page 19: ...18 Notes...

Page 20: ...defective under valid warranty coverage as described above Cosmetic damage that does not affect the process functionality of the equipment is not covered WaterTech Industries makes every effort to ens...

Reviews: