Page 4
WS1CT & WS1.25CT Manual
OEM System Setup
OEM General Instructions
Program
All times in Minutes
C1
1st Backwash
C2
Regenerate
C3
2nd Backwash
C4
Rinse
C5
Fill
P0
3
50
3
3
1-99
P1
8
50
8
4
1-99
P2
8
70
10
6
1-99
P3
12
70
12
8
1-99
P4
10
50
Skipped
8
1-99
P5
4
50
Skipped
4
1-99
P6
12
6
Skipped
12
1-99
P7
6
Skipped
Skipped
4
Skipped
P8
10
Skipped
Skipped
6
Skipped
P9
14
Skipped
Skipped
8
Skipped
STEP 3SS
– If program P0 through P6 was selected, enter in the minutes of
fi
ll using
▲
or
▼
.
The allowable values vary from 1 to 99. If program P7, P8 or P9 was selected, this screen will not
appear. Press SET to go to Step 4SS. Note: For each minute of
fi
ll 0.5 gallons of water is added to the
solution tank. With Sodium Chloride, each 0.5 gallon of water will dissolve 1.5 pounds of salt.
STEP 1SS
STEP 2SS
STEP 3SS
STEP 4SS
STEP 5SS
STEP 2SS
– Choose the desired program by pressing
▲
or
▼
. Press SET to go to Step 3SS
STEP 1SS
– From normal mode, press SET and
▲
simultaneously for 3 seconds and release. Then
press SET and
▲
simultaneously for 3 seconds and release.
STEP 6SS
– Timekeeping format – only viewed when DC power supply is used. Use
▲
or
▼
to
select 12 for 12 hour AM/PM format or 24 for 24 hour format.
Press SET to exit OEM System Setup.
STEP 6SS
STEP 4SS
— Use
▲
or
▼
to switch between:
• 1-99 Days Between Regen; or
• 7-Day.
Press SET to go to Step 5SS.
or
STEP 5SS
— If a differential pressure switch is installed and
actuated for a total of 2 minutes:
• a regeneration will occur immediately if no arrow points at Regen
Hour; or
• a regeneration will occur at the delayed regeneration hour if an
arrow points at Regen Hour.
Use
▲
or
▼
to switch between the two choices. If a differential
switch is not installed the settings in this display are ignored. Press
SET to go to Step 6SS.
RETURN TO
NORMAL MODE
or