If “E1,” “E2,” “E3” or “E4” appears on the display contact the OEM for help. This indicates that 
the valve did not function properly.

When the system is operating one of two displays will be shown. Pressing 

 or 

 will alternate 

between the displays. One of the displays is always the current time of day. The second display 
is the days remaining until the next regeneration. If the days remaining is equal to one, a 
regeneration will occur at the next preset regeneration time. The user can scroll between displays 
as desired.

If the system has called for a regeneration that will occur at the preset time of regeneration, the 
arrow will point to Regen.

Typically a system is set to regenerate at a time of low water usage. An example of a time with 
low water usage is when a household is asleep. If there is a demand for water when the system is 
regenerating, untreated water will be used.

When the system begins to regenerate, the display will change to the Regeneration Cycle Display 
to indicate the current regen cycle step and time remaining. An arrow will also point to Regen. The 
system will run through the steps automatically and will reset itself to provide treated water when 
the regeneration is completed.

Sometimes there is a need to regenerate the system sooner than when the system calls for it, 
usually referred to as a manual regeneration. There may be a period of heavy water usage because 
of guests or a heavy laundry day.

To initiate a manual regeneration at the preset delayed regeneration time, simultaneously press 

 

and 

 and release. The arrow will point to the word Regen if a regeneration is expected “tonight.”  

To cancel the regeneration simultaneously press 

 and 

 and release.

To initiate a manual regeneration immediately, simultaneously press 

 and 

 for three seconds. 

The system will begin to regenerate immediately. The request cannot be cancelled.
Note: For softeners, if brine tank does not contain salt, 

fi

 ll with salt and wait at least two hours 

before regenerating.

STEP 1U

 – Press SET. 

Step 2U – 

Current time: Adjust hour with 

 or 

. With 60 Hz line frequency detection on power-

up, timekeeping is 12 hour with PM indicator.  With 50 Hz line frequency detection on power-up, 
timekeeping is 24 hour without the PM indicator.  Press SET to go to Step 3U.

Step 3U - 

Adjust minutes with 

 or 

.  Press SET to exit Set Time of Day.

General Operation

Manual Regeneration

Error Message 

Set Time of Day

Regeneration Mode

STEP IU

STEP 2U

STEP 3U

An arrow will point to the 
word Regen if a regeneration 
is expected “tonight.”

Summary of Contents for WS1CT

Page 1: ...Water Specialist 1 Control Valve Series Model WS1CT 1 25 Control Valve Series Model WS1 25CT...

Page 2: ...Page 2 WS1CT WS1 25CT Manual...

Page 3: ...Page 3 WS1CT WS1 25CT Manual Table of Contents OEM System Setup 4 Installer Displays and Settings 5 User Displays 7 CT Front Cover and Drive Assembly 8...

Page 4: ...1SS STEP 2SS STEP 3SS STEP 4SS STEP 5SS STEP 2SS Choose the desired program by pressing or Press SET to go to Step 3SS STEP 1SS From normal mode press SET and simultaneously for 3 seconds and release...

Page 5: ...nd for approximately 3 seconds The number of days between regenerations may need to be varied based on usage and water conditions Step 2I7 Set Regeneration Time Hour Set the time for regeneration to s...

Page 6: ...ntil the arrow points to Regen If the arrow does not point to Regen a regeneration will not occur on Tuesday Press SET to go to STEP 8I7 STEP 8I7 Wednesday Regeneration To regenerate on Wednesday use...

Page 7: ...l reset itself to provide treated water when the regeneration is completed Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as a manual r...

Page 8: ...B REPL 1 5 V3110 WS1 DRIVE REDUCING GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER 1 Not Shown V3186 06 WS1 POWER SUPPLY US 15VDC HOCP 1 V3186EU 06 WS1 POWER SUPPLY EU 15VDC HOCP V3186UK 06 WS1 POWER SUPPL...

Page 9: ...Page 9 WS1CT WS1 25CT Manual...

Page 10: ...Page 10 WS1CT WS1 25CT Manual...

Page 11: ...Page 11 WS1CT WS1 25CT Manual...

Page 12: ...s SET to go to Step 12I7 Added STEP 12I7 PAGE 8 4 V3818TC 01 BOARD WS1 125 CT PCB REPLACE 1 Removed 7 V3106 01 from table and drawing Not Shown V3186 06 WS1 POWER SUPPLY US 15VDC HOCP 1 V3186EU 06 WS1...

Reviews: