WS1CC & WS1.25CC Manual
Page 7
For DIR Softeners, there are two options for setting the Gallons Capacity. The Gallons Capacity is automatically calculated if set to AUTO.
Reserve Capacity is automatically estimated based on water usage if AUTO is used. The other option is to set the Gallons Capacity to a specifi c
number. If a specifi c number is set, reserve capacity is zero, unless the value is manually set (i.e. the manufacturer intentionally sets the gallon
capacity number below the calculated capacity of the system).
The control valve can also be set to regenerate immediately or at the next regeneration time by changing the Regeneration Time Option. There
are three choices for settings:
1.
“NORMAL” means regeneration will occur at the preset regeneration time.
2.
“on 0” means regeneration will occur when the gallons capacity reaches zero.
3.
“NORMAL” and “on 0” means the regeneration will occur at the preset regeneration time unless the gallons capacity reaches zero. If the
gallons capacity reaches zero the regeneration will begin 10 minutes after no water usage.
The user can initiate manual regeneration. The user has the option to request the manual regeneration at the delayed regeneration time or to have
the regeneration occur immediately:
1.
Pressing and releasing the REGEN button. “Regen Today” will fl ash on the display and the regeneration will occur at the delayed
regeneration time. The user can cancel the request by pressing and releasing the REGEN button. This method of manually initiating
regeneration is not allowed when the system is set to “on 0”, i.e. to immediately regenerate when the gallon capacity reaches zero.
2.
Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration. The user cannot cancel this
request, except by resetting the control by pressing NEXT and REGEN buttons simultaneously for 3 seconds.
The WS1CC & WS1.25CC control valves consist of the following components:
1.
Drive Assembly
6. Drain Line Flow Control and Fitting Assembly
2.
Drive Cap Assembly, Main Piston and Regenerant Piston
7. Water Meter or Meter Plug
3.
Spacer Stack Assembly
8. Mixing Valve (optional)
4.
Injector Cap, Screen, Injector Plug and Injector
9. Installation Fitting Assemblies
5. Refi ll Flow Control Assembly or Refi ll Port Plug
10. Bypass Valve (optional)
Note: The WS1CC & WS1.25CC share many of the same components. Refer to Figure 6 for control valve identifi cation.
2
See Installer Display Settings, OEM Softener System Setup and OEM Filter System Setup for explanations of Day Override and
Gallon Capacity.
3
Day Override and Gallon Capacity can not both be set to “oFF” at the same time.
The control valve with a water meter can be set for Demand Initiated Regeneration (DIR) only, Time Clock operation only or DIR
and Time Clock which ever comes fi rst, depending upon what settings are selected for Day Override and Gallon Capacity.
2
See
Table 5.
If a control valve does not contain a meter, the valve can only act as a time clock, and day override should be set to any number and
gallon capacity should be set to off.
WS1CC & WS1.25CC
Downfl ow Regenerant
Refi ll After Rinse
WS1CC & WS1.25CC
Downfl ow
Regenerant Prefi ll
WS1CC & WS1.25CC
No Regenerant
1
st
Cycle: Backwash
2
nd
Cycle: dn Brine
3
rd
Cycle: Backwash
4
th
Cycle: Rinse
5
th
Cycle: Fill
6
th
Cycle: End
1
st
Cycle: Fill
2
nd
Cycle: Filtering
3
rd
Cycle: Backwash
4
th
Cycle: dn Brine
5
th
Cycle: Backwash
6
th
Cycle: Rinse
7
th
Cycle: End
1
st
Cycle: Backwash
2
nd
Cycle: Rinse
3
rd
Cycle: Backwash
4
th
Cycle: Rinse
5
th
Cycle: End
Table 4
Regeneration Cycles Filtering
Table 5
DIR/Time Clock Options
DIR
Time
Clock
Reserve Capacity
Softener
Filter
Settings
3
Regenerant
Backwash Day Gallon
Yes
Automatically calculated
Yes
Off
Auto
Yes
If desired enter a value less
than estimated capacity
Yes
Yes
Yes
Off
Any
Number
Yes
Yes
Automatically calculated
Yes
Any Number
Auto
Yes
Yes
If desired enter a value less
than estimated capacity
Yes
Yes
Yes
Any Number
Any
number
Yes
None
Yes
Yes
Yes
Any Number
Off
Summary of Contents for WS1CC
Page 2: ......
Page 13: ...WS1CC WS1 25CC Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Page 29: ...WS1CC WS1 25CC Manual Page 29 Drawings and Part Numbers...
Page 41: ...WS1CC WS1 25CC Manual Page 41 Flow Diagrams Service and Backwash...
Page 42: ...Page 42 WS1CC WS1 25CC Manual Flow Diagrams Downflow and Upflow WS1CC Only...
Page 43: ...WS1CC WS1 25CC Manual Page 43 Flow Diagrams Rinse and Fill...
Page 53: ...WS1CC WS1 25CC Manual Page 53...
Page 54: ...Page 54 WS1CC WS1 25CC Manual...
Page 55: ...WS1CC WS1 25CC Manual Page 55...
Page 56: ...Page 56 WS1CC WS1 25CC Manual...
Page 57: ...WS1CC WS1 25CC Manual Page 57...
Page 58: ...Page 58 WS1CC WS1 25CC Manual...
Page 59: ...WS1CC WS1 25CC Manual Page 59...