Page 14
WS1CC & WS1.25CC Manual
OEM General Instructions
The control valve offers multiple procedures that allow the valve to be modifi ed to suit the needs of the installation. These
procedures are:
•
OEM Cycle Sequence
•
OEM Softener System Setup
•
OEM Filter System Setup
•
Installer Display Settings
•
User Display Settings
• Diagnostics
• Valve
History
Once the OEM Cycle Sequence has been set, the other procedures can be accessed in any order. Details on each of the procedures
are provided on the following pages.
At the discretion of the manufacturer, the fi eld technician can access all settings. To “lock out” access to diagnostic and valve
history displays and modifi cations to settings except hardness, day override, time of regeneration and time of day by anyone but
the manufacturer, press
▼
, NEXT,
▲
, and SET CLOCK in sequence after settings are made. To “unlock”, so other displays can be
viewed and changes can be made, press
▼
, NEXT,
▲
, and SET CLOCK in sequence.
When in operation normal user displays such as time of day, gallons remaining before regeneration, days remaining before
regeneration or lbs. salt remaining before regeneration are shown. When stepping through a procedure, if no buttons are pressed
within fi ve minutes, the display returns to a normal user display. Any changes made prior to the fi ve minute time out are
incorporated. The one exception is current fl ow rate display under the diagnostic procedure. The current fl ow rate display has a 30
minute time out feature.
To quickly exit OEM Softener Setup, OEM Filter Setup, Installer Display Settings, Diagnostics or Valve History press SET
CLOCK. Any changes made prior to the exit are incorporated.
When desired, all information in Diagnostics may be reset to zero when the valve is installed in a new location. To reset
to zero, press NEXT and
▼
buttons simultaneously to go to the Service/OEM 1 screen, and release. Press
▲
and
▼
simultaneously to reset diagnostic values to zero. Screen will return to User Display.
Sometimes it is desirable to have the valve initiate and complete two regenerations within 24 hours and then return to the preset
regeneration procedure. It is possible to do a double regeneration if the control valve is set to “NORMAL” or “ on 0” in
OEM Softener System Setup or OEM Filter System Setup. To do a double regeneration:
1. Press the “REGEN” button once. REGEN TODAY will fl ash on the display.
2. Press and hold the “REGEN” button for three seconds until the valve regeneration initiates.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset regeneration time.
OEM Cycle Sequence
OEM Cycle Sequence instructions allows the OEM to set the order of
the cycle. The OEM Softener System Setup or the OEM Filter System
Setup allow the OEM to set how long cycles will last. The OEM may
choose up to 9 cycles in any order.
END must be used as the last cycle option. The SERVICE cycle
should only be used in brine prefi ll applications. See Tables 3 and 4 for
examples of typical softener or fi lter cycle sequences.
Prior to selecting dn brine or uP brine or not selecting a regenerant fl ow cycle, verify the correct valve body, main piston, regenerant
piston, and stack are being used, and that the injector or injector plug(s) are in the correct locations. See Compliance Table in
Service Instructions under Injector Cap, Screen, Injector Plug and Injector section and Figure 6.
The up fl ow cycle may not be used in the WS1.25CC control valve because the V3407 piston is designed for down fl ow use
only.
The following is an example of how to set a valve so that when regeneration is initiated BACKWASH occurs fi rst, dn BRINE occurs
second, RINSE occurs third, and FILL occurs fourth.
Cycle Options
BACKWASH
DN BRINE
FILL
END
RINSE
UP BRINE
(WS1CC Only)
SOFTENING
OR FILTERING
Summary of Contents for WS1CC
Page 2: ......
Page 13: ...WS1CC WS1 25CC Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Page 29: ...WS1CC WS1 25CC Manual Page 29 Drawings and Part Numbers...
Page 41: ...WS1CC WS1 25CC Manual Page 41 Flow Diagrams Service and Backwash...
Page 42: ...Page 42 WS1CC WS1 25CC Manual Flow Diagrams Downflow and Upflow WS1CC Only...
Page 43: ...WS1CC WS1 25CC Manual Page 43 Flow Diagrams Rinse and Fill...
Page 53: ...WS1CC WS1 25CC Manual Page 53...
Page 54: ...Page 54 WS1CC WS1 25CC Manual...
Page 55: ...WS1CC WS1 25CC Manual Page 55...
Page 56: ...Page 56 WS1CC WS1 25CC Manual...
Page 57: ...WS1CC WS1 25CC Manual Page 57...
Page 58: ...Page 58 WS1CC WS1 25CC Manual...
Page 59: ...WS1CC WS1 25CC Manual Page 59...