Troubleshooting Guide

SYMPTOM

PROBABLE CAUSE

CORRECTION

6. Loss of Water    

    Pressure

Scaling / fouling of inlet pipe

Clean or replace pipeline. Pretreat to 

prevent.

Fouled resin

Clean resin. Pretreat to prevent. 

Improper backwash setting

Backwash more frequently

7. Excessive Water 

    in Brine Tank 

    and / or Salty 

    Water to Service

Plugged drain line or drain line 

control

Check flow to drain. Clean drainline 

flow control button

Dirty or damaged brine valve

Clean or replace brine valve.

Plugged injector or screen

Clean or replace injector screen. 

Low inlet pressure

Increase pressure to allow injector 

to perform properly. (20 psi mini

-

mum)

Excessive brine refill cycle time

Lower brine refill time.

8. Softener Fails to

    Use Salt

Check items listed in #1

Improper control valve program-

ming

Check and reset programming

Plugged / restrict drain line

Clean drain line and / or flow control 

button

Injector and / or screen is plugged

Clean or replace injector and screen

No water in brine tank

Check for restriction in DLFC. Ensure 

safety float is not stuck. Check brine 

tank for leaks. 

Water pressure is too low

Line pressure must be at least 20 

psi.

Brine line injects air during brine 

draw

Check brine line connections for air 

leaks 

Internal control leak

Call dealer. Check piston, seals and 

spacers for scratches and dents.

9. Continuous Flow

    to Drain

Foreign material in control piston 

and seals

Call dealer. Clean valve and replace 

piston and seals. 

Internal control leak

Same as above.

Valve jammed in backwash, brine or 

rapid rinse position

Same as above.

Motor stopped or jammed

Check for jammed piston. Replace 

piston and seals. Replace motor if 

motor is unresponsive. 

Summary of Contents for DS24-3

Page 1: ...Softener Manual Installation Operation Manual...

Page 2: ...y Assembly ISO III Page 19 Bypass Assembly ISO III Page 21 Service Instructions Page 22 Troubleshooting Page 24 Error Codes Page 26 Warranty Information Page 28 FCC Compliance Statement http www chand...

Page 3: ...General Specifications DS24 3 DS24V 3 DS32 3 DS32V 3 DS48 3 DS48V 3 DS64 3 DS64V 3 DS96V 3 Grains Capacity Regeneration Lbs Salt Used 20 000 7 5 27 000 9 40 000 15 54 000 18 81 000 27 Maximum Raw Wat...

Page 4: ...ft water The surfaces of these beads are covered with sodium ions As hard water enters the mineral tank and comes into contact with the resin an exchange of ions takes place as dissolved Calcium and M...

Page 5: ...tallation Requirements A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the inlet to a water heater to prevent damage due to back up of hot water DO...

Page 6: ...ded All plumbing lines not requiring soft water should be connected upstream of the softener The brine tank drain line is gravity flow and must discharge below the overflow fitting The brine overflow...

Page 7: ...reads and fill the mineral tank completely with water Replace the valve being careful to posi tion the distributor tube into the distributor tube pilot hole Note If rebedding an existing unit and the...

Page 8: ...gs must be kept at a bare minimum Note Where the drain line is elevated above the control valve or exceeds 20 feet in length 3 4 I D drain line tubing should be used Brine Line and Overflow Connection...

Page 9: ...power is re stored The time will be offset by the increment of time the unit was without power so it is necessary to reset the time of day on the unit No other system will be affected Pressurizing Th...

Page 10: ...lay is accepted all digits will flash 3 To set A M or P M press the Menu Enter button To change digit value press the Set Change button Example A To accept the digit value press the Menu Enter button...

Page 11: ...e step With Gallons Remaining Until Next Regeneration at 0000 Press and hold the Set Change button After 3 seconds the regeneration cycle will begin 3 To Fast Cycle thru regeneration First complete ab...

Page 12: ...tion and allow the control valve to automatical ly fill the brine tank Note Control valve will advance to service position automatically Disinfection For disinfection of your unit please follow the Sa...

Page 13: ...l begin at the scheduled time A setting of zero will cancel this feature Example Override every 7 days A 07 default setting or cancel setting A 00 Maximum is 29 3 Regeneration Cycle Step Times Steps 1...

Page 14: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Page 15: ...ms in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on dev...

Page 16: ...p Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This wi...

Page 17: ...softener and water is to be used for lawn sprinkling or other similar uses 2 Servicing the water softener 3 A water leak from the water softener is evident 4 Shock treating water well and piping with...

Page 18: ...heel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Legacy View Motor Assy 20016X006 1 10 Lower Back Base for Cover...

Page 19: ...19 Valve Body Assembly 2 9 1 3 13 14 12 16 17 18 19 10 11 4 5 6 8 15 20 7 6A...

Page 20: ...0251X268 1 6 DLFC Assy 20017X100 1 7 90 Degree Hose Barb Elbow 20017X266 1 8 Drain Retainer 20017X214 1 9 Brine Valve 20561X225 1 10 DLFC Assembly 20001X228 1 11 DLFC Ferrule 3 8 20251X305 1 12 10 24...

Page 21: ...ll units 20017X284 3 1 Female Straight Slip Set optional 20017X288 4 1 NPT Straight Set optional 20017X289 5 3 4 NPT Straight Set optional 20017X307 6 3 4 Female Straight Slip Set optional 20017X290 7...

Page 22: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer...

Page 23: ...move meter from valve body and clean or replace as necessary 5 Reinstall meter nut and cable G To Replace Brine Valve 1 Follow Piston Replacement instructions After the piston is removed pull the brin...

Page 24: ...all times Clean it yearly Salt may be bridged If using a salt grid plate ensure refill water is over it Resin fouling Call dealer Find out how to con firm it Clean the resin and prevent future foulin...

Page 25: ...items listed in 1 Improper control valve program ming Check and reset programming Plugged restrict drain line Clean drain line and or flow control button Injector and or screen is plugged Clean or rep...

Page 26: ...coder connection If the encoder is plugged in and snapped into place skip to step 2 below If encoder is disconnected reconnect it and cycle power to clear the error 2 Disconnect powerhead from valve b...

Page 27: ...e following factors The electrical outlet is not powered or is switched off The power cable has come unplugged from the circuit board The power supply has come unplugged from your electrical outlet Th...

Page 28: ...administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatment equipment The Warranty does not cover any claims submitted to WATERSOFT more than 30 days af...

Reviews: