Water Right UltroWater Installation, Operation & Service Manual Download Page 4

4

SECTION II.   SPECIFICATIONS 

TABLE A – QUALIFIED SYSTEM PERFORMANCE 

  Because the performance of an R.O. Membrane is highly dependent upon pressure, temperature and TDS, the 

following should be used for comparison purposes only.

 

U.S. Metric

Membrane Production

1

 

41-53 gpd 

155–201 lpd

Membrane TDS Reduction

1

 

96% minimum 

96% minimum

System Production² 

12 gpd 

45 lpd

Recovery Rating

30% 

30%

Efficiency Rating

14% 

14%

TDS Reduction² 

90%+ typical 

90%+ typical

Drain (reject water) Flow 

3–5 x product flow 

3–5 x product flow

Empty Storage Tank Precharge 

5–7 psig air 

35–48 kPa air

Storage Tank Capacity

1.7 gallons 

 

6.4 liters

1

  Industry standards measure R.O. Membranes performance with no backpressure on the product water, at 65 psig (448kPa) and 77°F  

(25°C). Further  conditions on the above are 250 ppm TDS.  Production rate and TDS reduction figures are for a new Membrane that   

has been rinsed for 24 hours. The production  rate of a new Membrane can decrease by 10% per year or more, depending upon the    

scaling and fouling tendencies of the Feed Water. 

2

  Measured at 50 psig, 77°±2° F, 750±40 mg/l TDS per section 6 of NSF/ANSI Standard 58. Recovery rating means the percentage 

of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when 

the system is operated without a storage tank or when the storage tank is bypassed.  Efficiency rating means the percentage 

of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that 

approximate typical daily usage. This reverse osmosis system contains a replaceable component critical to the efficiency of 

the system. Replacement of the reverse osmosis component should be with one of identical specifications, as defined by the 

manufacturer, to assure the same efficiency and contaminant reduction performance.

TABLE B – RECOMMENDED OPERATING LIMITS FOR FEED WATER

Specifications   

T.F.C. Membrane

Water Pressure    

40–100 psig (280–690 kPa)

TDS   

2000 ppm (also mg/l) max.

Temperature    

40–100°F (4–38°C) 

pH    

4–11 (optimum rejection at pH 7.0 - 7.5)

Hardness    

Less than 10 gpg (170 mg/l) or soften

Iron    

Less than 0.1 ppm (also mg/l)

Manganese    

Less than 0.05 ppm (also mg/l)

Hydrogen Sulfide    

None

Chlorine    

See note

Bacteria    

Must be potable**

NOTE: Chlorine will damage a T.F.C. Membrane. The Activated Carbon Prefilter has been designed to reduce chlorine from the 

incoming water. Change filter every 6 to 12 months, more often if the water contains more than 1 ppm chlorine.

**DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY, WITHOUT ADEQUATE  

DISINFECTION BEFORE OR AFTER THE SYSTEM.

Summary of Contents for UltroWater

Page 1: ...rtified by NSF International against NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet R O Drinking Water System Model No UltroWater INSTALLATION OPERATION S...

Page 2: ...rtains to people with HIV AIDS patients receiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital...

Page 3: ...supply to prevent excess reject water from going to drain when the unit is not producing water WATER QUALITY MONITOR The optional Water Quality Monitor has been integrated into the faucet base for ins...

Page 4: ...is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influen...

Page 5: ...manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing TYPICAL ULTROWATER UNDER SINK INSTALLATION DIAGRAM The Water Qua...

Page 6: ...ne housing sediment CARBON MODULE BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper air gap must be created please check with local plumbing codes see exam...

Page 7: ...n area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the moun...

Page 8: ...ink Center punch the hole to provide a starting point for the drill Start with a smaller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch C...

Page 9: ...K 3 8 POLYTUBE TO DRAIN CLAMP BLACK 1 4 POLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fi...

Page 10: ...When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply line The supply line shoul...

Page 11: ...filter changes Mark the two locations the bracket can be used as a template Install the screws and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRIC...

Page 12: ...rds the manifold Take the remaining housing and insert housing O ring into its groove Engage and firmly tighten housing hand tight only Remove the plug labeled ACTIVATED CARBON from the underside of t...

Page 13: ...rval for changing the modules not the R O Membrane is every 6 to 12 months Typical T F C Membrane life expectancy is three years Local conditions may dictate more frequent changes NOTE If the R O Memb...

Page 14: ...tube out of the fitting 4 Firmly reconnect the polytubes to the new Post Filter Refer to Fig 5 5 Slowly open the Feed Water Saddle Valve 6 When water begins dripping out of the Faucet in the following...

Page 15: ...15...

Page 16: ...e check The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Hold...

Page 17: ...mbing Dissolved gasses in the Feed Water Pretreat Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Product Water section Drain Water overflows at the Dispensing...

Page 18: ...18 MADE IN USA Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 19 18 15 16 21 Nitrate Nitrite Test Kit 22 Water Quality Test Kit for systems without the Water Quality Monitor...

Page 19: ...4 S3010 Housing 15 R7078 Optional Water Quality Monitor w Probes and Cover 16 S2116 6 Drain Restrictor 60 GPD 227 lpd 17 S7125X Activated Carbon Module 18 S1405 1 4 3 8 Fitting Wrench 19 S3072 Wrench...

Page 20: ...for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life depends on fe...

Reviews: