Water Right UltroWater Installation, Operation & Service Manual Download Page 11

11

2.  Use a battery powered or properly grounded 

drill. Using the Clamp port as a drill guide,  

drill a 

7

/

32

" hole through the wall of the drain 

pipe. Do NOT penetrate the opposite side of 

the pipe. 

3.  Locate the 

3

/

8

" Black Drain Tubing connected 

to the Dispensing Faucet. Route to the tubing 

to the Drain Clamp and trim to length. 

  NOTE: When cutting the polytubing make  

clean, square cuts, failing to do so could 

result in poor connections and possible 

leaks. 

  CAUTION: The lowest point of the line 

should be the point of connection to the Drain 

Clamp. There should be no sag in the line as 

this may cause excessive noise as the reject 

water is flowing to drain.
•Refer to Fig. 4. Insert the tubing into the 

Drain Clamp. Make sure the tubing is 

pressed all the way in to create a pressure 

tight connection.

NOTE: If you want to pull the tubing out for 

some reason, push the ring around the 

tubing in and pull the tubing out.

D.  R.O. Manifold Assembly Installation 
  Locate the site per Sec. III, C.3. Various 

installation sites will require different types 

of mounting fasteners; be sure the fastener 

selected will provide a firm, solid mounting. 

A support panel may be necessary on thin 

cabinet walls or to span between wall studs on 

particleboard or drywall. 

  Do not drill through exterior cabinet walls or 

leave sharp wood screw points exposed in 

readily accessible cabinet interiors. 

  The close proximity of a dishwasher or a trash 

compactor may require special fabrication of a 

mounting plate. 
1.  The mounting bracket will accept either #10 

or #12 (5mm) mounting screws spaced on 

6" (15 cm) centers. Allow at least 4" (10 cm) 

of clearance beneath the filter housings to 

accommodate filter changes. Mark the two 

locations (the bracket can be used as a 

template). Install the screws and tighten them 

until the heads are about 

5

/

8

" from the wall.

RED

BLACK

YELLOW

IN

DRAIN

OUT

DRAIN 

RESTRICT

OR

2.  Locate the ¼" Red Feed Water Tubing. 

Remove the red plug from the fitting labeled 

“In” on the manifold and insert the tubing. 

Reference the special supplement sheet in 

the carton for proper connection of all tubing 

and removal of plugs. Run the tubing along 

its course to the Feed Water Saddle Valve, 

trim to length. (Refer to Fig. 1.) 

  Refer to Fig. 3. To the end of the red polytube 

install the Compression Nut, the  Plastic 

Ferrule, and the Insert. Connect to the Feed 

Water Saddle Valve.

3.  Locate the ¼" Black Drain Tubing connected 

to the Dispensing Faucet. Remove the black 

plug from the fitting labeled “Drain” on the 

manifold. The end of the Black Drain Tubing 

that should be inserted into the “Drain” port 

will have a drain restrictor in it. Allow the 

tubing to relax, then press drain restrictor 

firmly again to insure proper seating.

4.  Locate the ¼" yellow tubing with the tee 

attached to one end. Remove the yellow plug 

from the fitting labeled "Out" on the manifold 

and insert the tubing.

5.  Locate the 

3

/

8

" Blue Product Water Tubing 

attached to the Dispensing Faucet. Firmly 

press one end into the tee. (Refer to Fig. 1.) 

The fittings will grab the tubing and seal it in 

place. Make sure the tubing is pressed all the 

way in to create a pressure tight connection. 

  NOTE: If you want to pull the tubing out 

for some reason, push the ring around the 

tubing in and pull the tubing out. 

6.  Hang the Manifold Assembly on the 

mounting screws and tighten. DO NOT 

OVERTIGHTEN.

7.  Remove the wrapping from the  

In–Line Activated Carbon Post Filter. Slice 

the 

3

/

8

" Blue Polytube where it would be 

convenient to install and change the In–Line 

Filter. Make a clean straight cut to insure 

Summary of Contents for UltroWater

Page 1: ...rtified by NSF International against NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet R O Drinking Water System Model No UltroWater INSTALLATION OPERATION S...

Page 2: ...rtains to people with HIV AIDS patients receiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital...

Page 3: ...supply to prevent excess reject water from going to drain when the unit is not producing water WATER QUALITY MONITOR The optional Water Quality Monitor has been integrated into the faucet base for ins...

Page 4: ...is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influen...

Page 5: ...manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing TYPICAL ULTROWATER UNDER SINK INSTALLATION DIAGRAM The Water Qua...

Page 6: ...ne housing sediment CARBON MODULE BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper air gap must be created please check with local plumbing codes see exam...

Page 7: ...n area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the moun...

Page 8: ...ink Center punch the hole to provide a starting point for the drill Start with a smaller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch C...

Page 9: ...K 3 8 POLYTUBE TO DRAIN CLAMP BLACK 1 4 POLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fi...

Page 10: ...When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply line The supply line shoul...

Page 11: ...filter changes Mark the two locations the bracket can be used as a template Install the screws and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRIC...

Page 12: ...rds the manifold Take the remaining housing and insert housing O ring into its groove Engage and firmly tighten housing hand tight only Remove the plug labeled ACTIVATED CARBON from the underside of t...

Page 13: ...rval for changing the modules not the R O Membrane is every 6 to 12 months Typical T F C Membrane life expectancy is three years Local conditions may dictate more frequent changes NOTE If the R O Memb...

Page 14: ...tube out of the fitting 4 Firmly reconnect the polytubes to the new Post Filter Refer to Fig 5 5 Slowly open the Feed Water Saddle Valve 6 When water begins dripping out of the Faucet in the following...

Page 15: ...15...

Page 16: ...e check The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Hold...

Page 17: ...mbing Dissolved gasses in the Feed Water Pretreat Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Product Water section Drain Water overflows at the Dispensing...

Page 18: ...18 MADE IN USA Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 19 18 15 16 21 Nitrate Nitrite Test Kit 22 Water Quality Test Kit for systems without the Water Quality Monitor...

Page 19: ...4 S3010 Housing 15 R7078 Optional Water Quality Monitor w Probes and Cover 16 S2116 6 Drain Restrictor 60 GPD 227 lpd 17 S7125X Activated Carbon Module 18 S1405 1 4 3 8 Fitting Wrench 19 S3072 Wrench...

Page 20: ...for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life depends on fe...

Reviews: