14
C. Changing the In–Line Activated Carbon Post
Filter
1. Close the Feed Water Saddle Valve by
turning fully clockwise.
2. Close the Holding Tank Valve and then
open the Dispensing Faucet to release the
pressure.
3. Remove the In–Line Activated Carbon Post
Filter. Disconnect the used Post Filter by
pressing in the connector’s collar and at the
same time pulling the tube out of the fitting.
4. Firmly reconnect the polytubes to the new
Post Filter. (Refer to Fig. 5.)
5. Slowly open the Feed Water Saddle Valve.
6. When water begins dripping out of the
Faucet, in the following order, close the
Faucet and open the Holding Tank Valve.
When the Faucet is first opened, expect air
and carbon fines (very fine black powder),
from the new Post Filter to be rinsed out. This
is normal for the first tank of water.
IN–LINE ACTIVATED CARBON
POST FILTER ASSEMBLY
OUT
IN
In-Line Activated
Carbon Post Filter
3/8" Blue
To
Dispensing
Faucet
3/8" Blue
Figure 5
Summary of Contents for UltroWater