7
MAV DRIVE 1
SET
IN
DELAYED
SET
TYPE
OFF
VALVE TYPE
SET
1.0
AUXILIARY INPUT
SET
OFF
1
MIN
Pre-Service Rinse
SET
OFF
2
3
4
Configuration Screens
Accessed by pressing and holding
NEXT
and
–
simultaneously for three seconds.
Once screen changes, press and hold
NEXT
and
–
simultaneously again for three seconds.
Select meter size with + or — buttons
Set to 1”, 1.25”, 1.5”, 2” or 1.0T (for twin units). Upflow brining will not be an option if set to anything other than 1” or 1.0T.
With 1.0T set:
•
Meter calibration will be fixed with a different value for each tank.
•
MAV 1 setting will not be viewed, but forced to be set to Alternator Mode w/ Immediate Regen and Post Fill Brining.
•
The Backwash-Air regeneration step will not be available.
•
Default setting is 1”
Set auxilliary input with + or — buttons
•
IMMED indicates unit will regen immediately.
•
DELAY indicates that after a 2 minute signal from external contact, unit will regen at delayed regen time.
•
HOLD indicates that unit will not regen while external contacts are closed.
•
ALARM indicates that control valve’s internal alarm will sound upon external contact closure.
•
Default setting is OFF.
WARNING: External contact is needed to operate any of the above settings properly. If no external
contact is connected, no setting is needed.
Set regen time control with + or — buttons
•
DELAYED sets regen to specified regen time.
•
DELAY + IMMEDIATE sets regen to occur after 10 minutes of no water usage.
•
IMMEDIATE sets an immediate regen upon zero gallons of remaining capacity.
•
Default setting is DELAYED.
Set pre-service rinse time with + or — buttons
This option is only available if the valve type is set to 1.0T (twin).
Range is 0-20 minutes. Default setting is OFF.
Set first MAV drive control with + or — buttons
•
ALT A and ALT B are only used in twin configurations (see MAV manual for more details).
•
SYSTEM CONTROLLER configures board to operate with the Clack System Controller.
•
SEPARATE SOURCE changes state at the start and end of regen cycle.
•
NO HARD BYPASS configures MAV as a no hard water bypass.
•
TIME changes state at a set time referenced to the start of regen, for a preset duration of time independent
of actual regen status. Inactive during alternate regeneration cycle.
•
Default setting is OFF.
•
Screen not visible when unit is set to 1.0T
WARNING: Leaving valve in ALT A, ALT B or ENABLED without proper hardware will result in errors.
Only appears
on units set to
1.0T Mode