background image

7

MAV DRIVE 1

SET

IN

DELAYED

SET

TYPE

OFF

VALVE TYPE

SET

1.0

AUXILIARY INPUT

SET

OFF

1

MIN

Pre-Service Rinse

SET

OFF

2

3

4

Configuration Screens

Accessed by pressing and holding 

NEXT

 and 

 simultaneously for three seconds. 

Once screen changes, press and hold 

NEXT

 and 

 

simultaneously again for three seconds. 

Select meter size with + or — buttons

Set to 1”, 1.25”, 1.5”, 2” or 1.0T (for twin units). Upflow brining will not be an option if set to anything other  than 1” or 1.0T. 

With 1.0T set:

 

Meter calibration will be fixed with a different value for each tank.

MAV 1 setting will not be viewed, but forced to be set to Alternator Mode w/ Immediate Regen and Post Fill Brining.  

The Backwash-Air regeneration step will not be available.

Default setting is 1”

Set auxilliary input with + or — buttons

IMMED indicates unit will regen immediately.

DELAY indicates that after a 2 minute signal from external contact, unit will regen at delayed regen time.

HOLD indicates that unit will not regen while external contacts are closed.

ALARM indicates that control valve’s internal alarm will sound upon external contact closure.

Default setting is OFF.

WARNING: External contact is needed to operate any of the above settings properly. If no external 

contact is connected, no setting is needed. 

Set regen time control with + or — buttons

DELAYED sets regen to specified regen time.

DELAY + IMMEDIATE sets regen to occur after 10 minutes of no water usage.

IMMEDIATE sets an immediate regen upon zero gallons of remaining capacity.

Default setting is DELAYED.

Set pre-service rinse time with + or — buttons

This option is only available if the valve type is set to 1.0T (twin). 

Range is 0-20 minutes. Default setting is OFF. 

Set first MAV drive control with + or — buttons

ALT A and ALT B are only used in twin configurations (see MAV manual for more details).

SYSTEM CONTROLLER configures board to operate with the Clack System Controller.

SEPARATE SOURCE changes state at the start and end of regen cycle.

NO HARD BYPASS configures MAV as a no hard water bypass.

TIME changes state at a set time referenced to the start of regen, for a preset duration of time independent    

   of actual regen status. Inactive during alternate regeneration cycle. 

Default setting is OFF.

Screen not visible when unit is set to 1.0T

WARNING: Leaving valve in ALT A, ALT B or ENABLED without proper hardware will result in errors. 

Only appears 

on units set to 

1.0T Mode

continue to next page

Summary of Contents for Sanitizer Plus

Page 1: ...Master Programming Manual for Sanitizer Plus Models Effective February 2019...

Page 2: ...Set hours with or buttons AM PM toggles after 12 AM Displays time remaining in current regeneration cycle 2 flashes for a second backwash if two backwashes are programmed Displays time remaining incur...

Page 3: ...een See the service alarm section on page 4 to configure alarms Set minutes of regen time with or buttons If IMMEDIATE REGEN is set see Service OEM page regen will be immediate once total capacity is...

Page 4: ...ons remaining before the service alarm will trigger Press and hold the and buttons simultaneously for three seconds to reset to the gallon setpoint Status Display Shows the time remaining before the s...

Page 5: ...capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting The default setting is AUTO Set double regen point with or buttons If unit s capacity is...

Page 6: ...y such as in larger units Consult manufacturer before changing WARNING If resin media is used this setting MUST be set to OFF or LOW Set draw time with or buttons Default setting is 90 00 minutes Set...

Page 7: ...setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DELAYED...

Page 8: ...etpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or buttons This is the gallons that w...

Page 9: ...nit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by this press NEXT Set relay tr...

Page 10: ...hrough each hour of the day selected in the gallon usage history screen To select a different day press the REGEN button to return to the previous screen and select a new day with the or buttons NOTE...

Page 11: ...from tank Displays voltage consumed and brine draw time Errors will be recorded from all brine cycles Displays MAV drive time history for an active MAV 1 output Use or buttons to select a MAV output P...

Page 12: ...e to find proper park position 201 INVALID REGEN STEP Control can no longer operate properly due to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER...

Page 13: ...13 Notes...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN SAN PL MAST Rev A0219...

Reviews: