cont’d 

TOTAL REGENS

190

TOTAL DAYS

970

MON

GPM

12

MAX FLOW HISTORY

       TOTAL GALLONS

X1K

0

VVV

CYC

TTT

MAV 1 - FIRST

CCC

%BRINE

REGEN

15     100

5

6

7

8

BRINE DRAW TIME 1

4.6  2:17

TOTAL BRINE ERRORS

1

VLT

MIN

First Level History Screens  

 

 

 

 

 

 

        

Accessed by pressing and holding 

+

 and 

 simultaneously for three seconds. 

Returns to general display after five minutes of inactivity.

 

Displays peak flow rate history

Use 

+

 or 

 buttons to scroll through last 7 days to view peak 

flow rate for that day.

Displays brine concentration history

Use 

+

 or 

 buttons to scroll through last 50 regenerations to view brine 

concentration. Units with multiple brine cycles only record the first one. 

Displays voltage consumed and brine draw time

Use 

+

 or 

 buttons to scroll through last 50 regenerations to view voltage 

consumed along with the time it took to draw brine from tank.

Displays voltage consumed and brine draw time

Errors will be recorded from all brine cycles. 

Displays MAV drive time history for an active MAV 1 output

Use 

+

 or 

 buttons to select a MAV output. Pressing both 

+

 and 

 buttons

will reset this display.

First = Average of the first three drive times measured for that MAV in that direction.

Last = Last drive time measured for that MAV in that direction.

Ave = Current average drive time calculated for that MAV in that direction.

TTT = Relative MAV drive time measured (First/Last/Ave).

CCC = Total number of cycles in/out for that MAV.

VVV = Relative MAV drive voltage measured (First/Last/Ave).

Displays total days unit has been in service

Displays total regens since startup

Displays total gallons used by Meter 1  

input since last reset

Press and hold 

+

 and 

 buttons simultaneously for 

three seconds to reset this value back to 0 gallons.

Only appears on units 

equipped with chlorine 

generator option

Only appears on 

units equipped 

with MAV.

return to  

general display

continued from 

previous page

Summary of Contents for Sanitizer Plus

Page 1: ...Master Programming Manual for Sanitizer Plus Models Effective February 2019...

Page 2: ...Set hours with or buttons AM PM toggles after 12 AM Displays time remaining in current regeneration cycle 2 flashes for a second backwash if two backwashes are programmed Displays time remaining incur...

Page 3: ...een See the service alarm section on page 4 to configure alarms Set minutes of regen time with or buttons If IMMEDIATE REGEN is set see Service OEM page regen will be immediate once total capacity is...

Page 4: ...ons remaining before the service alarm will trigger Press and hold the and buttons simultaneously for three seconds to reset to the gallon setpoint Status Display Shows the time remaining before the s...

Page 5: ...capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting The default setting is AUTO Set double regen point with or buttons If unit s capacity is...

Page 6: ...y such as in larger units Consult manufacturer before changing WARNING If resin media is used this setting MUST be set to OFF or LOW Set draw time with or buttons Default setting is 90 00 minutes Set...

Page 7: ...setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DELAYED...

Page 8: ...etpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or buttons This is the gallons that w...

Page 9: ...nit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by this press NEXT Set relay tr...

Page 10: ...hrough each hour of the day selected in the gallon usage history screen To select a different day press the REGEN button to return to the previous screen and select a new day with the or buttons NOTE...

Page 11: ...from tank Displays voltage consumed and brine draw time Errors will be recorded from all brine cycles Displays MAV drive time history for an active MAV 1 output Use or buttons to select a MAV output P...

Page 12: ...e to find proper park position 201 INVALID REGEN STEP Control can no longer operate properly due to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER...

Page 13: ...13 Notes...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN SAN PL MAST Rev A0219...

Reviews: