8
PROGRAMMING THE ELECTRONIC CONTROLLER
:
1. Enter 3200NT Programming Mode
Press and hold both the Set Up and Set Down buttons for five (5)
seconds to enter Programming Mode. When the program mode is
entered, the program light illuminates.
2. Set Feed Water Hardness
The feed water hardness setting displays only if the Regeneration
Type is set to Meter Immediate or Meter Delayed.
— Press the Set Up and Set Down buttons to set the amount
of feed water hardness (in grains/gallon). The system
automatically calculates treated water capacity based
on the feed water hardness and the system capacity.
— Press the Extra Cycle button to proceed to the next step.
3. Set Regeneration Time
A non-flashing colon between two sets of numbers identifies the
Regeneration Time display. Set the desired time of day that you
want Regeneration to occur.
— Press the Set Up and Set Down buttons to adjust this value.
— Press the Extra Cycle button to proceed to the next step.
4. Set Regeneration Day Override
Use this display to set the maximum amount of time (in days) the
unit can be In Service without a Regeneration.
NOTE:
The manufacturer has preset this to every 6 days.
— For System 4 Time Clock regeneration mode, the system
regenerates at the time set in Step 4 after the number of
days programmed in this step.
— For all other System Types (4 Meter Immediate, 4 Meter
Delayed, 5, 6, 7, 9), the system regenerates after the number
of days programmed in this step unless the meter initiates a
Regeneration cycle earlier.
— Press the Extra Cycle button to proceed to the next step.
Timer programming is complete and exits from the
Programming Mode. Normal operation resumes.