background image

24

25

SPECIFICATIONS

Impression Series

®

Specifications

Please use “IMP” as prefix when specifying Impression Plus Series

water softeners .

Manufactured by Water-Right, Inc.  •  1900 Prospect Court  •  Appleton, WI 54914  •  800-777-1426  •  water-right.com                 

 

    

                              

                      SPE-IM/IMP SOFT RevB0821

CYCLE TIMES AND USAGE

1

  All Impression water softeners are set at medium salting. All Impression Plus water softeners are set at 

minimum salting. 

2

  Iron removal may vary depending on form of iron, pH and other local conditions. On waters that are 

pre-chlorinated or where other pre-oxidation occurs, an iron precipitate can form that is too small 

to be filtered.

3

  Unit not tested for capacity at these flow rates. Water quality may vary.

MODEL

IM-844

IMP-844

IM-1044

IMP-1044

IM-1054

IMP-1054

IM-1354

IMP-1354

IMC-835

IMPC-835

IMC-1035

IMPC-1035

1

Capacity:

(Grains/Lbs. NaCI)

Minimum

15,600 @ 3.0

23,600 @ 6.0

35,400 @ 9.0

53,000 @ 12.0

13,600 @ 3.0

23,600 @ 6.0

Medium

21,600 @ 6.0

28,400 @ 9.0

44,400 @ 15.0

64,200 @ 18.0

18,000 @ 6.0

28,400 @ 9.0

Maximum

25,600 @ 9.0

32,000 @ 15.0

48,800 @ 21.0

72,800 @ 24.0

21,000@ 9.0

32,000 @ 15.0

Amount of Media (Cu. Ft.)

.75

1.0

1.5

2.5

0.5

1.0

Maximum Water Hardness (GPG)

50

75

100

100

50

75

2

Maximum Iron (PPM)

1.0

1.0

1.0

1.0

1.0

1.0

3

Peak Flow Rate (GPM @ P-PSI)

11.4 @ 15.0

17.1 @ 15.0

14.3 @ 15.0

18.5 @ 15.0

12.2 @ 15.0

17.1 @ 15.0

Con� nuous Flow Rate (GPM @ P-PSI)

  

5.0 @ 5.4

5.0 @ 2.8

5.0 @ 3.8

5.0 @ 2.4

5.8 @ 5.0

5.0 @ 2.8

Water Pressure Range (PSI) 

25-100

25-100

25-100

25-100

25-100

25-100

Water Temp. (ºF)  

33-100

33-100

33-100

33-100

33-100

33-100

Electrical Requirements (volts-hertz)

110-50/60

110-50/60

110-50/60

110-50/60

110-50/60

110-50/60

Pipe Size

1”

1”

1”

1”

1”

1”

Total Dimensions:

Media Tank and Valve

8”W x 52”H

10”W x 52”H

10”W x 62”H

13”W x 62”H

14”W x 44.5”H x 

20.5”

14”W x 44.5”H x 

20.5”

Brine Tank

18”W x 33”H

18”W x 33”H

18”W x 33”H

18”W x 40”H

MODEL

IMRC-1054

IMPRC-1054

IMRC-1354

IMPRC-1354

1

Capacity:

(Grains/Lbs. NaCI)

Minimum

23,600 @ 6.0

35,400 @ 9.0

Medium

28,400 @ 9.0

44,400 @ 15.0

Maximum

32,000 @ 15.0

48,800 @ 21.0

Amount of Resin Media (Cu. Ft.)

1.0

1.5

Amount of Carbon Media (Cu. Ft.)

.5

1.0

Maximum Water Hardness (GPG)

75

100

2

Maximum Iron (PPM)

1.0

1.0

3

Peak Flow Rate (GPM @ P-PSI)

15.6 @ 15.0

20.4 @ 15.0

Con� nuous Flow Rate (GPM @ P-PSI)

  

9.7 @ 7.5

13.2 @ 7.5

Water Pressure Range (PSI) 

25-100

25-100

Water Temp. (ºF)  

33-100

33-100

Electrical Requirements (volts-hertz)

110-50/60

110-50/60

Pipe Size

1”

1”

Total Dimensions:

Media Tank and Valve

10”W x 62”H

13”W x 62”H

Brine Tank

18”W x 33”H

18”W x 40”H

MODEL

IM-844

IMP-844

IM-1044

IMP-1044

IM-1054

IMP-1054

IM-1354

IMP-1354

IMC-835

IMPC-835

IMC-1035

IMPC-1035

IMRC-1054

IMPRC-1054

IMRC-1354

IMPRC-1354

MIN .

GAL .

MIN .

GAL .

MIN .

GAL .

MIN .

GAL .

MIN .

GAL .

MIN .

GAL .

MIN .

GAL .

MIN .

GAL .

Brine Refill

4

2

6

3

10

5

12

6

4

2

6

3

6

3

10

5

The above sequence takes place prior to regeneration; therefore minutes are not included in totals

Backwash 

6

10

8

22

8

22

10

32

6

10

8

22

8

42

8

60

Brine & Rinse

40

16

60

24

90

36

90

47

40

16

60

24

60

24

90

47

Rapid Rinse

4

7

4

11

4

11

4

13

4

7

4

11

4

21

4

30

Total

50

35

72

60

102

74

104

98

50

35

72

60

72

90

102

142

IM/IMP/IMC/IMPC SPECIFICATIONS

IMRC/IMPRC SPECIFICATIONS

Width

Height

Cabinet Models

Width

Height

Depth

Low Profi le Cabinet

High Profi le Cabinet

Cabinet dimensions represent the High-Profile cabinet option. Low-Profile cabinets    

are about one inch shorter in height than the High-Profile cabinet lid. 

Summary of Contents for IM-1044

Page 1: ...Installation Instructions Owner s Manual Impression Impression Plus Series Impression Impression Plus RC Series Metered Water Softeners For Models IM IMP IMC IMPC IMRC IMPRC IMT IMPT...

Page 2: ...ully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer YOUR WATE...

Page 3: ...Flow rate capacity remaining and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general operatin...

Page 4: ...es point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve for normal operation of a water softener or filter During the regeneration...

Page 5: ...nds the use of an expansion tank on the outlet side of the unit see diagram 5 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to temperatur...

Page 6: ...tube to its discharge point in accordance with plumbing codes Pay special attention to codes for air gaps and anti siphon devices CAUTION Never insert a drain line into a drain sewer line or trap Alw...

Page 7: ...7 This page intentionally left blank...

Page 8: ...gallons Adjustable from 1 to 150 gpg in 1 grain increments default setting is 20 The hardness value is based on the actual compensated hardness of the water and must be set by an authorized dealer fo...

Page 9: ...nlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly there will be a loss of media to the drain 3 When the wate...

Page 10: ...y water use is anticipated or when the system has been operating without salt To initiate a manual regeneration at the next preset regeneration time press and release the REGEN button The words REGEN...

Page 11: ...ndicates that the control valve was not able to function properly 6 BRINE TANK MAINTENANCE AND SALT Refill the brine tank as necessary making sure at least 1 3 of the brine tank is full at all times W...

Page 12: ...B Connect meter to three pin connection labeled METER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into...

Page 13: ...debris and if necessary replace H Damaged seal stack assembly piston H Replace seal stack assembly and or piston I Control valve body type and piston type mix matched I Verify proper control valve bod...

Page 14: ...n the PC board labeled MOTOR Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC bo...

Page 15: ...V NHBP motor to PC board two pin connection labeled DRIVE Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 secon...

Page 16: ...ory screens These do not flash when error occurs A Occurs when dP input is active for ALARM and the input is closed The alarm buzzer will activate and the screen will display the error A Check for low...

Page 17: ...over 1 CV3540P W A 100244820 Gray Impression Plus cover 1 2 CV3107 1 100246273 Motor Assembly 1 3 CV3002 A 100246193 Drive assembly includes 5 and 6 4 CV3579WI 03 100246387 PC board Impression 1 CV422...

Page 18: ...generant piston 1 6 CV3001 04 100244557 1 body assembly downflow 1 CV3001 04UP 100243827 1 body assembly upflow 1 CV3020 100246239 1 25 body assembly downflow 1 7 CV3541 100249867 Drive backplate 1 No...

Page 19: ...1 4 CV3163 100246291 O ring 019 1 BYPASS VALVE Item No Legacy Part Current Part Description Qty 1 CV3006 100249845 Bypass assembly 1 2 CV3147 100246284 Bypass handles 2 Loosens Injector And Bypass Cap...

Page 20: ...E injector assembly CV3010 1F 100246215 F injector assembly CV3010 1G 100246216 G injector assembly CV3010 1H 100246217 H injector assembly CV3010 1I 100246218 I injector assembly CV3010 1J 100246219...

Page 21: ...FC 1 Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item Legacy Part Current Part Description Qty 1 CH4615 100245862 Elbow lock...

Page 22: ...ll 18 x 33 BT 1 CH1030 36S 100245841 4 x 36 slotted brine well 18 x 40 24 x 40 BTs 1 5 CH1018 100245836 2 piece overflow set 1 6 CH4500 48 100245857 474 air check assembly 1 2 x 48 1 7 CH4600 50 10024...

Page 23: ...Brine Assembly 1 Not shown CH4850 34 625 100173701 Brine Well with Brine Well 474 Assembly 34 5 8 1 LOW PROFILE CABINET AND BRINE TANK Item Legacy Part Current Part Description Qty 1 CJ2TCWSLP C 1002...

Page 24: ...tion Qty CV3007 15 100246200 3 4 john guest elbow assembly 2 1 JOHN GUEST Legacy Part Current Part Description Qty CV3007 17 100245045 1 john guest assembly 2 1 1 4 1 1 2 BRASS SWEAT Legacy Part Curre...

Page 25: ...110 50 60 110 50 60 Pipe Size 1 1 1 1 1 1 Total Dimensions Media Tank and Valve 8 W x 52 H 10 W x 52 H 10 W x 62 H 13 W x 62 H 14 W x 44 5 H x 20 5 14 W x 44 5 H x 20 5 Brine Tank 18 W x 33 H 18 W x 3...

Page 26: ...art or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equiva...

Page 27: ...power outage 1 Accessed by pressing 2 Adjust hours with or buttons AM PM toggles at 12 3 Press 4 Adjust minutes with or buttons 5 Press 6 Adjust current day with or buttons 7 Press to complete and ret...

Page 28: ...2021 Water Right Inc All rights reserved MAN IM IMP SOFT RevA1221 1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406...

Reviews: