14
continued from previous page
E. ADJUSTABLE FAST RINSE TIME
1
. If you completed the previous step, the fast rinse
time adjust screen should show in the display (See
Figure 24). Otherwise, press and hold for 3 sec-
onds the SELECT button, until the display shows
“000 - -“, then press the SELECT button five times
to display the fast rinse time adjust screen.
Controller Features / Options
1
. Press and hold the SELECT button until “000 - -”
shows in the display (See Figure 25).
3
. Use the
r
UP or
s
DOWN buttons to display the
desired selection, then press the SELECT button.
If you selected anything other than CF, the display
will return to the normal run (time of day) screen.
If setting to CF (Chemical Feeder), there will be
two additional settings to make for operating the
chemical feeder in Steps 4 and 5, below.
2
. Use the
r
UP or
s
DOWN buttons to adjust fast
rinse time from 0 to 99 minutes.
3
. When the desired fast rinse time is displayed,
press the SELECT button. Press the SELECT but-
ton several times to advance through the remaining
screens and return to the normal run (time of day)
display.
F. AUXILIARY OUTPUT CONTROL
The electronic controller’s auxiliary output may be
used to operate various types of external equipment,
such as a chlorine generator or chemical feeder. It
provides a 24V DC, up to 500 mA, current from termi-
nal J4 on the electronic control board (see Schematic
on page 17). The table below explains the choices
available for when the auxiliary output will be on dur-
ing various portions of the recharge cycle.
FIG. 24
FIG. 26
FIG. 27
FIG. 28
FIG. 25
2
. Press the SELECT button six times, until “Ctrl"
flashes in the display (See Figure 26).
*
A turbine and turbine cable must be added to the system if auxiliary output selections “FS” or “CF” are to be used.
The default is OFF. If you wish to change to one of
the other selections shown in the table:
4
.
CHEMICAL FEEDER TRIP VOLUME:
If you have
set the auxiliary output control to CF (Chemical
Feeder), you will need to set the volume of water
which must flow past the turbine* before the auxil-
iary output is turned on. With the alternating
screens in Fig. 27 shown, use the
r
UP or
s
DOWN buttons to set the trip volume, in gal-
lons. Then press the SELECT button to display the
screen shown in Fig. 28.
5
.
CHEMICAL FEEDER TIME:
Use the
r
UP or
s
DOWN buttons to set the length of time, in
seconds, that the auxiliary output will be turned on.
Then press the SELECT button to accept and
return to the normal run (time of day) screen.
SELEC-
TION
NAME
AUXILIARY OUTPUT
FUNCTION
OFF
Off
Remains off indefinitely.
BP
Bypass
On during the entire recharge.
CL
Chlorine
On during the brine draw portion
of the recharge.
FS
Flow
Switch
On when water is flowing past
the turbine*. It will shut off 8
seconds after water flow stops.
CF
Chemical
Feeder
After the set volume of water
has flowed past the turbine*,
turns on for the time set (see
Steps 4 & 5, below, to set vol-
ume and time).
FR
Fast
Rinse
On during the fast rinse por-
tion of the recharge.