Programming the Electronic Controller
B. SET DAYS BETWEEN RECHARGES
1
. If you completed the previous step, the word
“RECHARGE" should show in the display (See
Figure 14). Otherwise, press the SELECT button
several times until it does.
2
. The default setting is 3 days. This means that the
filter will recharge every 3 days. See the chart
below to determine the frequency of recharges. To
change the number of days between recharges,
use the
r
UP or
s
DOWN buttons to adjust from
1 to 99 days.
3
. When the desired number of days is displayed,
press the SELECT button, and the display will
change to show the next setup screen.
FIG. 14
NOTE:
I
f there is an iron bleed or the water supply has high turbidity (sand, silt, sedi-
ments, etc.), set the filter to regenerate more often than the table above shows.
NOTE:
In some extreme iron conditions, a fill setting of 2 minutes (3 ounces of
potassium permanganate used), or 3 minutes (4 oz.) could be needed
for each regeneration.
NOTE:
If hydrogen sulfide is present, decrease the number of days between
recharges by one or more (to a minimum setting of 1 day between
recharges) until contaminant is removed.
C. SET RECHARGE START TIME
1
. If you completed the previous step, the words
“RECHARGE TIME" should show in the display
(See Figure 15). Otherwise, press the SELECT
button several times until they do.
Number
of
People
Iron
(parts per million)
2
4
6
8
10
15
20
1
7 days 6 days 5 days 4 days 3 days 3 days 2 days
2
6 days 5 days 3 days 3 days 2 days
1 day
1 day
3
5 days 3 days 2 days 2 days
1 day
1 day
1 day
4
4 days 3 days 2 days
1 day
1 day
1 day
1 day
5
4 days 2 days
1 day
1 day
1 day
1 day
1 day
6
3 days 2 days
1 day
1 day
1 day
1 day
1 day
7
3 days
1 day
1 day
1 day
1 day
1 day
1 day
8
2 days
1 day
1 day
1 day
1 day
1 day
1 day
2
. The filter’s default recharge start time is 12:00 AM.
This is normally a time of day when water is not
being used in the household. If you have a water
softener or another filter installed, the recharge
start times should be offset to assure adequate
water flow and pressure. For example, if the water
softener is set to begin recharge at 2:00 AM, set
the filter to start recharge at 12:00 AM, or 4:00 AM.
Use the
r
UP or
s
DOWN buttons to adjust the
FIG. 15
SUGGESTED DAYS BETWEEN RECHARGES
recharge start time.
3
. When the desired recharge
time is displayed, press
the SELECT button, and
the display will change to
show the normal run (time
of day) display.